Study on the performance of different types of three-dimensional chromatographic systems

被引:27
|
作者
Davydova, Ekaterina [1 ]
Schoenmakers, Peter J. [1 ]
Vivo-Truyols, Gabriel [1 ]
机构
[1] Univ Amsterdam, Analyt Chem Grp, Vant Hoff Inst Mol Sci, NL-1090 GD Amsterdam, Netherlands
关键词
Three-dimensional liquid chromatography; Spatial chromatography; LC x LC x LC; Peak capacity; 2-DIMENSIONAL LIQUID-CHROMATOGRAPHY; PARETO-OPTIMALITY; PEAK-CAPACITY; SEPARATION; COLUMN;
D O I
10.1016/j.chroma.2012.11.043
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The maximum achievable performance of possible types of three-dimensional chromatographic systems (LC x LC x LC) has been investigated. The Pareto-optimization approach was applied to establish a trade-off between three main objectives (total peak capacity, analysis time and dilution of the sample) and Pareto-front values were obtained. The performances of (LC)-L-x x (LC)-L-x x (LC)-L-x (three-dimensional separation in space), (LC)-L-t x (LC)-L-t x (LC)-L-t (three-dimensional separation in time) and the hybrid (LC)-L-x x (LC)-L-x x (LC)-L-t system were compared mutually and with two-dimensional chromatographic systems. It was found that (LC)-L-x x (LC)-L-x x (LC)-L-x performs best in terms of maximum achievable peak capacity in shortest analysis time. Based on current thin-layer-chromatography performance it should be possible to obtain a peak capacity of 50,000 within 20 min. If contemporary column-packing standards can be upheld the achievable limit is approximately 50% higher. However, in an (LC)-L-x x (LC)-L-x x (LC)-L-x chromatographic system analytes remain in the separation domain after the analysis, which complicates the detection. Use of an (LC)-L-x x (LC)-L-x x (LC)-L-t system with elution in the last dimension alleviates the detection problem. The maximum achievable peak capacity in the same analysis time is lower for (LC)-L-x x (LC)-L-x x (LC)-L-t than for (LC)-L-x x (LC)-L-x x (LC)-L-x. Using the same (reasonable) length of the separation domain (e.g. a cube 200 x 200 x 200 mm) for both systems, it is possible to achieve peak capacities of 78,000 for (LC)-L-x x (LC)-L-x x (LC)-L-t operated in the gradient mode, which is twice higher than for an (LC)-L-x x (LC)-L-x x (LC)-L-x system. A three-dimensional (three-column) time-based (LC)-L-t x (LC)-L-t x (LC)-L-t system does not greatly improve the performance of (LC)-L-t x (LC)-L-t in terms of (maximum) peak capacity and (minimum) analysis time. Dilution factors in (LC)-L-t x (LC)-L-t x (LC)-L-t are very high. Decreasing the dilution has a detrimental influence on the peak capacity. The trade-off between these objectives is of crucial importance. The influence of several parameters (length of the separation domain, particle size, etc.) on the performance of chromatographic systems was investigated, optimal ranges were found. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [1] Cooling of different IRS systems: A three-dimensional comparative study
    Chandrakar, Vikrant
    Mukherjee, Arnab
    Senapati, Jnana Ranjan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 145
  • [2] Determination of different types of fixed effects in three-dimensional panels*
    Lu, Xun
    Miao, Ke
    Su, Liangjun
    ECONOMETRIC REVIEWS, 2021, 40 (09) : 867 - 904
  • [3] Three-Dimensional Analysis of the Pharyngeal Airway Space in Different Malocclusion Types
    Ahn, Hyun-Na
    Jeon, Eun-Young
    Lee, Jeong-Hyun
    Park, Jong -Tae
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2022, 51 (11) : 2629 - 2631
  • [4] Three-dimensional molecular simulation of chromatographic separations
    McGuffin, VL
    Wu, PR
    JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) : 3 - 17
  • [5] The morphological features of different Schatzker types of tibial plateau fractures: a three-dimensional computed tomography study
    Pengbo Chen
    Hao Shen
    Wei Wang
    Binbin Ni
    Zhiyuan Fan
    Hua Lu
    Journal of Orthopaedic Surgery and Research, 11
  • [6] The morphological features of different Schatzker types of tibial plateau fractures: a three-dimensional computed tomography study
    Chen, Pengbo
    Shen, Hao
    Wang, Wei
    Ni, Binbin
    Fan, Zhiyuan
    Lu, Hua
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
  • [8] Three-dimensional Monte Carlo simulation of grain growth with different lattice types
    School of Materials Science and Engineering, Shandong University, Ji'nan 250061, China
    Zhongguo Youse Jinshu Xuebao, 2008, 4 (728-732):
  • [9] Comparison of the Joint Space in Different Types of Malocclusion Using Three-Dimensional Models
    Jeon, Eun-Young
    Lee, Jeong-Hyun
    Park, Jong-Tae
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2020, 49 (07) : 1382 - 1384
  • [10] The three-dimensional impulse response of a boundary layer to different types of wall excitation
    Sundaram, Prasannabalaji
    Sengupta, Tapan K.
    Bhaumik, Swagata
    PHYSICS OF FLUIDS, 2018, 30 (12)