Seismic Fragility Evaluation of Multi-Branch Piping Systems installed in Critical Low-Rise Buildings

被引:0
|
作者
Ju, BuSeog [1 ]
Jung, WooYoung [2 ]
机构
[1] N Carolina State Univ, Dept Civil Engn, Raleigh, NC 27695 USA
[2] GangNeung WonJu Natl Univ, Dept Civil Engn, Kangnung 210702, South Korea
来源
DISASTER ADVANCES | 2013年 / 6卷 / 04期
基金
新加坡国家研究基金会;
关键词
Seismic; Piping; Fragility; Monte-Carlo; Probability; T-joint; Multi-Branch;
D O I
暂无
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The failure of nonstructural components such as piping, ceiling, mechanical and electrical equipments led to operational and functional problems in structural system during the past severe earthquakes. Consequently, in the last few decades, a reduction of the damage to nonstructural components or an improvement on the performance of nonstructural component has emerged as a key area of research. The primary objective of this research was to develop the seismic fragility of the piping system incorporating the multi T-joint branch piping systems. The procedure for evaluating fragility curves corresponding to the first damage limit state considered the effects of each floor acceleration-sensitivity for low-rise RC and steel frame building structures subjected to 50 selected ground motions as function of uncertainties. The result of this study revealed that the conditional probability of failure to the piping system on each floor level in critical facilities increased with increased level of floor and in fact, floor level in low-rise buildings can tune the fragilities between the building and the piping system.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [1] Seismic fragility evaluation of piping system installed in critical structures
    Ju, Bu Seog
    Jung, Woo Young
    Ryu, Yong Hee
    STRUCTURAL ENGINEERING AND MECHANICS, 2013, 46 (03) : 337 - 352
  • [2] Seismic fragility assessment of low-rise stone masonry buildings
    Abo-El-Ezz, Ahmad
    Nollet, Marie-Jose
    Nastev, Miroslav
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2013, 12 (01) : 87 - 97
  • [3] Seismic fragility assessment of low-rise stone masonry buildings
    Ahmad Abo-El-Ezz
    Marie-José Nollet
    Miroslav Nastev
    Earthquake Engineering and Engineering Vibration, 2013, 12 : 87 - 97
  • [4] Seismic fragility assessment of low-rise stone masonry buildings
    Ahmad Abo-El-Ezz
    Marie-José Nollet
    Miroslav Nastev
    EarthquakeEngineeringandEngineeringVibration, 2013, 12 (01) : 87 - 97
  • [5] Seismic Fragility Evaluation of Retrofitted Low-Rise RC Structures
    Noureldin, Mohamed
    Kim, Jinkoo
    INNOVATIVE SOLUTIONS FOR SOIL STRUCTURE INTERACTION, 2020, : 1 - 12
  • [6] Fragility Assessments of Multi-Story Piping Systems within a Seismically Isolated Low-Rise Building
    Ryu, Yonghee
    Kwag, Shinyoung
    Ju, Bu-Seog
    SUSTAINABILITY, 2018, 10 (10)
  • [7] Seismic fragility of low-rise piloti buildings based on 2017 Pohang earthquake damage
    Kim, Taewan
    Park, Ji-Hun
    Yu, Eunjong
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [8] SEISMIC DESIGN OF LOW-RISE STEEL BUILDINGS
    MONTGOMERY, CJ
    HALL, WJ
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1979, 105 (10): : 1917 - 1933
  • [9] Seismic evaluation of low-rise reinforced masonry buildings with flexible diaphragms
    Cohen, Gregory L.
    Klingner, Richard E.
    Hayes, John R., Jr.
    Sweeney, Steven C.
    MASONRY, 2008, 1496 : 109 - +
  • [10] Performance Evaluation of Seismic Force-Resisting Systems for Low-Rise Steel Buildings in Canada
    Yang, T. Y.
    Murphy, M.
    EARTHQUAKE SPECTRA, 2015, 31 (04) : 1969 - 1990