Deformable Breast MRI and CT Registration for Radiation Treatment Planning Using B-spline With Rigidity and Feature Point Distance Regularization

被引:0
|
作者
Yang, C. [1 ]
White, J. [1 ]
Li, X. A. [1 ]
机构
[1] Med Coll Wisconsin, Milwaukee, WI 53226 USA
关键词
D O I
10.1016/j.ijrobp.2012.07.189
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S111 / S111
页数:1
相关论文
共 40 条
  • [1] MRI-To-CT Deformable Registration for Treatment Planning of Breast Irradiation
    Godley, A.
    Ahunbay, E.
    Paulson, E.
    White, J.
    Li, X.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Feasibility Study of B-Spline Deformable Registration between CT and MRI Atlas for Trigeminal Neuralgia Application to Radiosurgery
    Peroni, M.
    Stancanello, J.
    Muacevic, A.
    Riboldi, M.
    Spadea, M. F.
    Sharp, G. C.
    Baroni, G.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1649 - 1652
  • [3] Optimizing B-Spline Deformable Image Registration Between Planning CT and Cone-Beam CT in Head and Neck Cancer Patients
    Nakano, M.
    Kierkels, R.
    Hanaoka, S.
    Korevaar, E.
    Imae, T.
    Haga, A.
    Sijtsema, M.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [4] Multimodal image registration by edge attraction and regularization using a B-spline grid
    Klein, Almar
    Kroon, Dirk-Jan
    Hoogeveen, Yvonne
    Kool, Leo J. Schultze
    Renema, W. Klaas Jan
    Slump, Cornelis H.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [5] Deformable Registration Method by Joint Using TPS and B-Spline for Lung Cancer in Radiotherapy
    Han, N.
    Xie, Y.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [6] A New Deformable Image Registration Method Based on B-Spline for Clinical 4D CT
    Wang, Hui
    Yin, Yong
    Wang, Hongjun
    Li, Dengwang
    MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2012, 195-196 : 566 - 571
  • [7] Non-rigid Registration based on B-spline using Point Matching
    Lim, Jae Hwan
    Kim, Young Hwan
    2015 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2015, : 95 - 96
  • [8] B-spline deformable image registration algorithm evaluation using numerical and physical phantom.
    Badey, A.
    Tolsa, S.
    Bodez, V.
    Khamphan, C.
    Jaegle, E.
    Alayrach, M. E.
    Martinez, P.
    Garcia, R.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1133 - S1134
  • [9] Deformable Registration of Chest Radiographs Using B-spline Based Method with Modified Residual Complexity
    Xiang Z.
    Li M.
    Xiao L.
    Lian Z.
    Wei Z.
    Journal of Shanghai Jiaotong University (Science), 2019, 24 (02): : 226 - 232
  • [10] Deformable Registration of Chest Radiographs Using B-spline Based Method with Modified Residual Complexity
    相志康
    李敏
    肖亮
    练智超
    韦志辉
    JournalofShanghaiJiaotongUniversity(Science), 2019, 24 (02) : 226 - 232