Characteristics of the arrangement of the cooling water piping system for ITER and fusion reactor power station

被引:0
|
作者
Chang, K. P. [1 ]
Kuehn, Ingo [2 ]
Curd, W. [1 ]
Dell'Orco, G. [1 ]
Gupta, D. [1 ]
Fan, L. [1 ]
Kim, Yong-Hwan
机构
[1] ITER IO, Cooling Water Syst Sect, F-13103 St Paul Les Durance, France
[2] ITER IO, Project Off, F-13103 St Paul Les Durance, France
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
The ITER has been designed to demonstrate the scientific and technical feasibility of nuclear fusion energy conversion using the tokamak magnetic machine. The ITER design and operating experience will guide the realization of a future fusion power plant called DEMO which will be designed to produce electricity at competitive cost with other energy sources. ITER will be operated as a tokamak machine and requires many plasma components and plasma diagnostic equipment. The cooling water absorbs the heat from the plasma facing components composed of the first wall/blanket (FWBLK), divertor/limiter (DIV/LIM) that operate at higher heat loads than reached in a nuclear fission power plant reactor. Following the long-term fusion study and research of the international ITER experiment, the characteristics and considerations in the arrangement of the equipment and piping for the cooling water system can be deduced. The cooling water system for a fusion reactor has many differences from the equipment and piping arrangement of a fission plant. This paper introduces ITER cooling water system design and offers an insight into the design features that will be considered in a future fusion reactor power station like DEMO. To meet its objectives, fusion specific piping design follows many of the design concept adopted in the nuclear power plant but additional special features should be taken into account in the design.
引用
收藏
页码:113 / +
页数:2
相关论文
共 50 条
  • [1] CRITICAL DESIGN ISSUES OF THE TOKAMAK COOLING WATER SYSTEM OF ITER'S FUSION REACTOR
    Kim, Seokho H.
    Berry, Jeanette B.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 60 (01) : 156 - 160
  • [2] Seismic Design of ITER Component Cooling Water System-1 Piping
    Singh, Aditya P.
    Jadhav, Mahesh
    Sharma, Lalit K.
    Gupta, Dinesh K.
    Patel, Nirav
    Ranjan, Rakesh
    Gohil, Guman
    Patel, Hiren
    Dangi, Jinendra
    Kumar, Mohit
    Kumar, A. G. A.
    10TH ASIA PLASMA AND FUSION ASSOCIATION CONFERENCE (APFA), 2017, 823
  • [3] FUSION-REACTOR CHILLED WATER COOLING SYSTEM
    POLIMEROS, G
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1978, 20 (12): : 61 - 61
  • [4] Barking Reach Power Station cooling water system
    Evans, JF
    Hodgkins, DJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 1997, 120 (01) : 15 - 26
  • [5] Maximum allowable fluid velocity and concern on piping stability of ITER Tokamak cooling water system
    Kim, Seokho
    FUSION ENGINEERING AND DESIGN, 2021, 162
  • [6] A CONVENIENT ARRANGEMENT OF SECONDARY COOLING WATER SYSTEM IN POWER PLANT UNITS
    MEYERKAHRWEG, H
    BRENNSTOFF-WARME-KRAFT, 1970, 22 (05): : 239 - +
  • [7] Tritium mass balance in the piping system of a fusion reactor
    Nishikawa, Masabumi
    Takeishi, Toshiharu
    Kawamura, Yoshinon
    Takagi, Yuji
    Matsumoto, Yuzuru
    Fusion Technology, 1992, 21 (2 pt 2): : 878 - 882
  • [8] POWER STATION COOLING WATER IN ESTUARIES
    JARMAN, RT
    DETURVIL.CM
    DOCK & HARBOUR AUTHORITY, 1968, 49 (572): : 66 - &
  • [9] Piping installation for reactor heavy water system
    Ye, Lin
    Huang, Hong-Wen
    Xu, Xian-Qi
    Qian, Da-Zhi
    Zhou, Wei
    Hedongli Gongcheng/Nuclear Power Engineering, 2008, 29 (02): : 66 - 69
  • [10] Replacement of the feedwater piping system in the reactor building outside the containment at Philippsburg I nuclear power station
    Kessler, A
    Labes, M
    Schwenk, B
    NUCLEAR ENGINEERING AND DESIGN, 1999, 193 (03) : 255 - 264