An In Vitro evaluation of disinfection protocols used for needleless connectors of central venous catheters

被引:8
|
作者
Mazher, M. A. [1 ]
Kallen, A. [1 ]
Edwards, J. R. [1 ]
Donlan, R. M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Healthcare Qual Promot, Atlanta, GA 30333 USA
关键词
chlorhexidine gluconate plus isopropanol; disinfection; isopropanol; needleless connector; povidone-iodine; CRITICALLY-ILL PATIENTS; POVIDONE-IODINE; CHLORHEXIDINE; INFECTION; CONTAMINATION; ANTISEPTICS; ALCOHOL; TRIAL;
D O I
10.1111/lam.12108
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A repeatable and sensitive method to evaluate the effect of three antiseptics and two disinfection techniques on viable micro-organisms on luer-activated catheter needleless connectors (NCs) was developed. NCs were inoculated with Staphylococcus epidermidis or Klebsiella pneumoniae and disinfected with 315% chlorhexidine gluconate+70% isopropanol (CGI), 70% isopropanol (IPA) or 10% PVP povidone-iodine (PI) antiseptic pads using: (i) scrubbing the NC septum and threaded external surfaces or (ii) wiping only the surface of the septum. Treatments were also evaluated against NCs pretreated with human serum and exposed for 18h to Staph.epidermidis prior to testing. Viable cells were quantified by plate count. The method for inoculation and recovery of luminal micro-organisms was repeatable (SD, 031; n=28). IPA disinfection provided an approximate 3log(10)CFU reduction; CGI and PI provided 3-4 log(10) reductions. PI and CGI were more effective than IPA (P<005), but differences between CGI and PI were not significant for either disinfection method. IPA, but not CGI and PI was also less effective (P<005) against NCs inoculated with Kl.pneumoniae than Staph.epidermidis. Pretreatment with serum and prolonged Staph.epidermidis inoculation removed the advantage seen with CGI and PI; log(10) reductions were 180, 173 and 250 for CGI, PI and IPA, respectively. PI or CGI may be more effective than IPA for NC disinfection but effectiveness may be reduced on NCs contaminated with blood or serum. Significance and Impact of the Studysensitive and repeatable protocol was developed to evaluate antiseptics for disinfecting catheter needleless connectors (NCs). Povidone-iodine (PI) and chlorhexidine gluconate plus isopropanol (CGI) were more effective than isopropanol (IPA) for reducing Staphylococcus epidermidis contamination of NCs. The effectiveness of PI and CGI was reduced on NCs pre-exposed to human serum and prolonged bacterial inoculation. IPA was also less effective against NCs contaminated with Klebsiella pneumoniae.
引用
收藏
页码:282 / 287
页数:6
相关论文
共 50 条
  • [1] Protocol for detection of biofilms on needleless connectors attached to central venous catheters
    Donlan, RM
    Murga, R
    Bell, M
    Toscano, CM
    Carr, JH
    Novicki, TJ
    Zuckerman, C
    Corey, LC
    Miller, JM
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) : 750 - 753
  • [2] Disinfection of central venous access device needleless connectors: A human factors analysis
    Drews, Frank A.
    Martinello, Richard A.
    Hebden, Joan N.
    St John, Keith H.
    Pegues, David A.
    [J]. INFECTION CONTROL & HOSPITAL EPIDEMIOLOGY, 2024,
  • [3] Disinfection of needleless connectors for catheters in one second using a hand-held UV device
    Fourkas, Michael
    Takami, Eri
    Schears, Gregory J.
    Farr-Jones, Shauna
    Rasooly, Julia
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2024, 52 (08) : 915 - 918
  • [4] Cultures of Needleless Connectors Are Useful for Ruling Out Central Venous Catheter Colonization
    Guembe, Maria
    Jesus Perez-Granda, Maria
    Cruces, Raquel
    Martin-Rabadan, Pablo
    Bouza, Emilio
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (07) : 2068 - 2071
  • [5] Evaluation of tow types of dressings used on central venous catheters for hemodialysis
    Neves Monteiro de Barros, Luciene de Fatima
    Arenas, Valquiria Grego
    de Cassia Bettencourt, Ana Rita
    Diccini, Solange
    Fram, Dayana Souza
    Silva Belasco, Angelica Goncalves
    Barbosa, Dulce Aparecida
    [J]. ACTA PAULISTA DE ENFERMAGEM, 2009, 22 : 481 - 486
  • [6] Pressures used to flush central venous catheters
    Primhak, RH
    Gathercole, N
    Reiter, H
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1998, 78 (03): : F234 - F234
  • [7] Thrombogenicity testing of central venous catheters in vitro
    Böswald, M
    Lugauer, S
    Bechert, T
    Greil, J
    Regenfus, A
    Guggenbichler, JP
    [J]. INFECTION, 1999, 27 (Suppl 1) : S30 - S33
  • [8] CENTRAL VENOUS CATHETERS Impregnated central venous catheters should be readily used to reduce risk of bloodstream infection
    Gilbert, Ruth
    Harron, Katie
    Mok, Quen
    Gamble, Carrol
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2013, 347
  • [9] In vitro evaluation of fluid reflux after flushing different types of needleless connectors
    Elli, Stefano
    Abbruzzese, Chiara
    Cannizzo, Luigi
    Lucchini, Alberto
    [J]. JOURNAL OF VASCULAR ACCESS, 2016, 17 (05): : 429 - 434
  • [10] Microbial Biofilms on Needleless Connectors for Central Venous Catheters: Comparison of Standard and Silver-Coated Devices Collected from Patients in an Acute Care Hospital
    Perez, Elizabeth
    Williams, Margaret
    Jacob, Jesse T.
    Reyes, Mary Dent
    Tejedor, Sheri Chernetsky
    Steinberg, James P.
    Rowe, Lori
    Ganakammal, Satishkumar Ranganathan
    Changayil, Shankar
    Weil, M. Ryan
    Donlan, Rodney M.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (03) : 823 - 831