Modeling the Performance of ECM and SCR Series Fan-Powered Terminal Units in Single-Duct VAV Systems

被引:0
|
作者
Davis, Michael A. [1 ]
Bryant, John A. [2 ]
O'Neal, Dennis L. [3 ]
机构
[1] New York Univ Abu Dhabi, Abu Dhabi, U Arab Emirates
[2] Texas A&M Univ, Doha, Qatar
[3] Texas A&M Univ, Dwight Look Coll Engn, College Stn, TX USA
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Single-duct variable-air-volume systems often use series- and parallel fan-powered terminal units to control the airflow in conditioned spaces. A laboratory-verified model of single-duct variable-air-volume systems was developed to simulate both series and parallel fan terminal units where the terminal unit fans are controlled by either silicon-controlled rectifiers or electronically commutated motors. The paper provides the equation needed to simulate the performance of a fan-powered terminal unit. The simulation model developed here includes a five-zone office building whose performance was simulated in five cities in the United States: Houston, Phoenix, Chicago, New York, and San Francisco. The model includes total plant energy, total cooling plant energy, primary fan energy, terminal unit fan energy, and heat energy added. The single-duct variable-air-volume simulation results showed that the reduction in the annual energy used by the office building with series-fan-powered terminal units having electronically commutated motors compared to series units having silicon-controlled rectifier-controlled motors varied by location. The largest energy savings for the building was in Phoenix (8.4%), while the smallest was in Chicago (5.9%). In all cases, the reduction in electricity used by the terminal unit fans with electronically commutated motors was near 65%. These results indicate that using fan-powered terminal units with electronically commutated motors offers the potential for sizable savings in energy compared to units with silicon-controlled rectifier-controlled motors.
引用
收藏
页码:908 / 919
页数:12
相关论文
共 30 条
  • [1] Modeling the Performance of ECM and SCR Parallel Fan-Powered Terminal Units in Single-Duct VAV Systems
    Davis, Michael A.
    Bryant, John A.
    O'Neal, Dennis L.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 920 - 929
  • [2] Modeling the Performance of Single-Duct VAV Systems that use Fan Powered Terminal Units
    Davis, Michael A.
    Bryant, John A.
    O'Neal, Dennis L.
    Cramlet, Andrew
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 308 - +
  • [4] Part Three Fan-Powered VAV Terminal Units Issues With Fan-Powered Terminal Unit Modeling
    Faris, Gus
    Int-Hout, Dan
    O'Neal, Dennis
    Yin, Peng Solomon
    ASHRAE JOURNAL, 2017, 59 (12) : 42 - 45
  • [5] Performance of VAV series fan-powered terminal units: Experimental results and models
    Furr, James C.
    O'Neal, Dennis L.
    Davis, Michael A.
    Bryant, John A.
    Cramlet, Andrew
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 91 - +
  • [7] Performance of VAV fan-powered terminal units: Experimental setup and methodology
    Furr, James C.
    O'Neal, Dennis L.
    Davis, Michael A.
    Bryant, John A.
    Cramlet, Andrew
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 75 - +
  • [8] Performance of VAV parallel fan-powered terminal units: Experimental results and models
    Furr, James C.
    O'Neal, Dennis L.
    Davis, Michael A.
    Bryant, John A.
    Cramlet, Andrew
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 83 - +
  • [9] Comparison of performance characteristics of SCR and ECM controlled series fan powered terminal units
    O'Neal, Dennis L.
    Edmondson, Jacob L.
    Yin, Peng Solomon
    HVAC&R RESEARCH, 2014, 20 (02): : 194 - 202
  • [10] Performance of Series Fan-Powered Terminal Units with Electronically Commutated Motors
    Edmondson, Jacob L.
    O'Neal, Dennis L.
    Bryant, John A.
    Davis, Michael A.
    ASHRAE TRANSACTIONS 2011, VOL 117, PT 2, 2011, 117 : 876 - 884