Optical assessment of tissue anisotropy in ex vivo distended rat bladders

被引:15
|
作者
Alali, Sanaz [1 ,2 ]
Aitken, Karen J. [3 ]
Shroeder, Annette [3 ]
Bagli, Darius J. [3 ]
Vitkina, I. Alex [1 ,2 ,4 ]
机构
[1] Univ Toronto, Div Biophys & Bioimaging, Ontario Canc Inst, Inst Hlth Network, Toronto, ON M5G 2M9, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[3] Univ Toronto, Div Urol Dev & Stem Cell Biol, Sick Kids Hosp, Toronto, ON M5G 1X8, Canada
[4] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
polarized light imaging; retardance; birefringence; anisotropy; bladder; urology; nonlinear microscopy; optical coherence tomography; MUELLER MATRIX DECOMPOSITION; URINARY-BLADDER; POLARIZED-LIGHT; SMOOTH-MUSCLE; MONTE-CARLO; TURBID MEDIA; SCATTERING; POLARIMETRY; MICROSCOPY; COLLAGEN;
D O I
10.1117/1.JBO.17.8.086010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microstructural remodelling in epithelial layers of various hollow organs, including changes in tissue anisotropy, are known to occur under mechanical distension and during disease processes. In this paper, we analyze how bladder distension alters wall anisotropy using polarized light imaging (followed by Mueller matrix decomposition). Optical retardance values of different regions of normal rat bladders under different distension pressures are derived. Then optical coherence tomography is used to measure local bladder wall thicknesses, enabling the calculation of the tissue birefringence maps as a measure of the tissue anisotropy. Selected two-photon microscopy is also performed to better understand the compositional origins of the obtained anisotropy results. The dome region of the bladder shows maximum birefringence when the bladder is distended to high pressures, whereas the ventral remains roughly isotropic during distension. In addition, the average anisotropy direction is longitudinal, along the urethra to dome. The derived wall anisotropy trends are based on birefringence as an intrinsic property of the tissue organization independent of its thickness, to aid in understanding the structure-functions relation in healthy bladders. These new insights into the wall microstructure of ex vivo distending bladders may help improve the functionality of the artificially engineered bladder tissues. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.8.086010]
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Optical assessment of tissue anisotropy in ex vivo distended rat bladders (vol 17, 086010, 2012)
    Alali, Sanaz
    Aitken, Karen J.
    Schroeder, Annette
    Bagli, Darius J.
    Vitkina, I. Alex
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)
  • [2] Optical assessment of anisotropy in ex vivo rat bladders
    Alali, Sanaz
    Aitken, Karen J.
    Bagli, Darius J.
    Vitkin, I. Alex
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [3] Ex vivo assessment of the optical characteristics of human brain and tumour tissue
    Shapey, Jonathan
    Xie, Yijing
    Nabavi, Elham
    Ebner, Michael
    Maneas, Efthymios
    Saeed, Shakeel R.
    Dorward, Neil
    Kitchen, Neil
    Desjardins, Adrien E.
    Ourselin, Sebastien
    Jaunmuktane, Zane
    Brandner, Sebastian
    Bradford, Robert
    Vercauteren, Tom
    LABEL-FREE BIOMEDICAL IMAGING AND SENSING (LBIS) 2020, 2020, 11251
  • [4] Ex vivo functional evaluation of isolated strips in BAMG tissue-engineered bladders
    Chen, Baisong S.
    Zhang, Shengli L.
    Geng, Hongquan
    Pan, Jun
    Chen, Fang
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (03): : 159 - 165
  • [5] Diffusion Anisotropy in Fresh and Fixed Prostate Tissue Ex Vivo
    Bourne, Roger M.
    Bongers, Andre
    Chatterjee, Aritrick
    Sved, Paul
    Watson, Geoffrey
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) : 626 - 634
  • [6] Optical Clearing of Ex Vivo Adipose Tissue
    Yanina, Irina Yu.
    Genina, Elina A.
    Tuchina, Daria K.
    Timoshina, Polina A.
    Navolokin, Nikita A.
    Bucharskaya, Alla B.
    Maslyakova, Galina N.
    Tuchin, Valery V.
    LASERS IN SURGERY AND MEDICINE, 2024, 56 (10) : 829 - 835
  • [7] Quantitative optical biopsy of liver tissue ex vivo
    Beuthan, J
    Minet, O
    Muller, G
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) : 906 - 913
  • [8] Tissue Optical Clearing Imaging from Ex vivo toward In vivo
    Zhu, Dan
    Tuchin, Valery
    BME FRONTIERS, 2024, 5
  • [9] Ex vivo optical metabolic measurements from cultured tissue reflect in vivo tissue status
    Walsh, Alex J.
    Poole, Kristin M.
    Duvall, Craig L.
    Skala, Melissa C.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [10] ASSESSMENT OF HEPATOBILIARY FUNCTION IN-VIVO AND EX-VIVO IN THE RAT
    HANDLER, JA
    KOSSOR, DC
    GOLDSTEIN, RS
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1994, 31 (01) : 11 - 19