A new type of aortic valved stent with good stability and no influence on coronary artery

被引:0
|
作者
Cai, Jianzhi [1 ]
Huang, Haitao [2 ]
Zhou, Yongxin [1 ]
Mei, Yunqing [1 ]
Shao, Jie [1 ]
Wang, Yongwu [1 ]
机构
[1] Tongji Univ, Tongji Hosp, Dept Thorac & Cardiovasc Surg, Shanghai 200065, Peoples R China
[2] Nantong Univ, Dept Thorac & Cardiovasc Surg, Affiliated Hosp 2, Nantong 226001, Jiangsu, Peoples R China
来源
关键词
Aortic valved stent; Transcatheter aortic valve implantation; Retrograde; PERCUTANEOUS TRANSCATHETER IMPLANTATION; HEART-VALVES; HIGH-RISK; REPLACEMENT; STENOSIS; PROSTHESIS; COREVALVE; DISEASE; RETROGRADE;
D O I
10.1186/1749-8090-8-210
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We evaluated the feasibility and safety of new aortic valved stents in transcatheter aortic valve implantation (TAVI) using retrograde approach by in vitro testing and animal implantation. Materials and Methods: The fluid passing test, expanding and releasing tests, static and releasing tests in tube were performed for new valved stents. Transvalvular pressure gradient, effective orifice area, pre-implantation and post-implantation regurgitant volume for the new stents were detected. Then, the new stents were implanted in six pigs using retrograde approach. These pigs were euthanized 12 h after the implantation for anatomic evaluation. Results: In vitro tests showed that the closure of the new stents leaflets were effective, and stents could be released through catheter, then expanded completely and fixed fast in the tube. The coronary artery flow rates did not changed significantly after implantation (P > 0.05), while aortic regurgitant volumes were obviously reduced (P < 0.05). No significant difference in the transvalvular pressure gradient and effective orifice area of the new stents implanted within or above the valve leaflets was found (P > 0.05). In vivo experiments indicated that TAVI was successfully performed in six pigs using retrograde approach. However, one pig was died 10 h after the implantation since the stent was not expanded completely. The leaflets in stents were opening well and no valvular regurgitation was observed in the other five pigs. And thrombosis was not found. Discussion and Conclusion: The new type of aortic valved stent designed in this study was characterized with good stability and could avoid the impact caused by valve leaflets on the coronary artery.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A new type of aortic valved stent with good stability and no influence on coronary artery
    Jianzhi Cai
    Haitao Huang
    Yongxin Zhou
    Yunqing Mei
    Jie Shao
    Yongwu Wang
    Journal of Cardiothoracic Surgery, 8
  • [2] A new type of coronary artery stent
    Evans, A.
    Davies, R. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (03) : 435 - 436
  • [3] Percutaneous Valved Stent Implantation Above the Coronary Ostia - A New Transitional Treatment for Acute Aortic Valve Rupture
    Zong, Gang-Jun
    Bai, Yuan
    Wu, Gang-Yong
    Jiang, Hai-Bing
    Qin, Yong-Wen
    CIRCULATION JOURNAL, 2011, 75 (08) : 1872 - 1877
  • [4] PERCUTANEOUS VALVED STENT IMPLANTATION ABOVE THE CORONARY OSTIA: A NEW TRANSITIONAL TREATMENT FOR ACUTE AORTIC VALVE RUPTURE
    Zong Gang-jun
    Bai Yuan
    Wu Gang-yong
    Xia Yan
    Qin Yong-wen
    HEART, 2010, 96 : A167 - A168
  • [5] Testosterone and estrogen influence collagen type I production in coronary artery and aortic fibroblasts
    Jenkins, Cathleen
    Milsted, Amy
    Doane, Kathleen
    Meszaros, Gary
    Ely, Daniel
    FRONTIERS IN NEUROENDOCRINOLOGY, 2006, 27 (01) : 16 - 16
  • [6] An aortic dissection treated with left main coronary artery stent implantation
    Guz, Goksel
    Altun, Ibrahim
    Karaayvaz, Bilal
    Akin, Fatih
    Kocaaga, Mehmet
    Atesal, Sebahattin
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2014, 10 (04): : 314 - 316
  • [7] A new self-expandable aortic valved stent deployed above native leaflets for aortic insufficiency: an in vitro study
    Huang, H.
    Zhou, Y.
    Shao, J.
    Cai, J.
    Mei, Y.
    Wang, Y.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2012, 53 (06): : 777 - 782
  • [8] Ultrasound navigation through the heart for off pump aortic valved stent implantation: New tools for new goals
    Huber, CH
    Nasratulla, M
    Augstburger, M
    von Segesser, LK
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 (04) : 503 - 510
  • [9] Stenting of a left main coronary artery dissection and stent-graft implantation for acute type a aortic dissection
    Imoto, K
    Uchida, K
    Suzuki, S
    Isoda, S
    Karube, N
    Kimura, K
    JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (02) : 258 - 261
  • [10] Management of a Protruding Right Coronary Artery Stent During Aortic Valve Replacement for Aortic Stenosis
    Nwaejike, Nnamdi
    Rozario, Christopher
    Sogliani, Franco
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2012, 7 (03) : 213 - 216