Dichlorodiphenyltrichloroethane determination in air by thermal desorption gas chromatography-mass spectrometry
被引:5
|
作者:
Martin, Nicholas J.
论文数: 0引用数: 0
h-index: 0
机构:
USN, Med Res Ctr, Silver Spring, MD 20910 USA
Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USAUSN, Med Res Ctr, Silver Spring, MD 20910 USA
Martin, Nicholas J.
[1
,2
]
Smith, Philip A.
论文数: 0引用数: 0
h-index: 0
机构:
Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
US Dept Labor OSHA, Hlth Response Team, Sandy, UT USAUSN, Med Res Ctr, Silver Spring, MD 20910 USA
Smith, Philip A.
[2
,3
]
Brown, Carlis W.
论文数: 0引用数: 0
h-index: 0
机构:
Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
US Marine Corps Chem Biol Incident Response Force, Indian Head, MD USAUSN, Med Res Ctr, Silver Spring, MD 20910 USA
Brown, Carlis W.
[2
,4
]
Achee, Nicole L.
论文数: 0引用数: 0
h-index: 0
机构:
Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USAUSN, Med Res Ctr, Silver Spring, MD 20910 USA
Achee, Nicole L.
[2
]
DeLong, Gerald T.
论文数: 0引用数: 0
h-index: 0
机构:
Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USAUSN, Med Res Ctr, Silver Spring, MD 20910 USA
DeLong, Gerald T.
[2
]
机构:
[1] USN, Med Res Ctr, Silver Spring, MD 20910 USA
[2] Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
[3] US Dept Labor OSHA, Hlth Response Team, Sandy, UT USA
[4] US Marine Corps Chem Biol Incident Response Force, Indian Head, MD USA
BACKGROUND: Current quantitative methods for airborne dichlorodiphenyltrichloroethane (DDT) require collection and extraction times of = 12 h. The aim of this study was to develop a method for quantifying airborne DDT with a short (<4 h) collection and analysis time. RESULTS: Precision [relative standard deviation (RSD)] for each calibration point (0.89.0), linearity (R2 = 0.99) and apparent recovery (R' = 96.5%) were determined from thermal desorption (TD) gas chromatographymass spectrometry (GC-MS) analyses of Tenax-TA-packed sampling tubes spiked with 1250 ng of DDT. Recovery of 13C-labeled 4,4'-DDT from tubes spiked before and after air sampling was 97.3 and 90.3% respectively. DDT was detected and quantified in 13 L samples of air collected during 10180 min sampling events. A significant difference was observed in DDT air concentration between 28 and 33 degrees C during microchamber studies. CONCLUSIONS: The results demonstrate that the TD GC-MS method developed in this study is precise, reproducible and linear over the span of 1250 ng of DDT spiked onto TD tubes. By avoiding dilution of the sample, the method described allows the measurement of DDT vapor concentrations during short sampling periods (10180 min) relevant to mosquito behavior studies. Published 2012 by John Wiley & Sons, Ltd.
机构:
Fed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, GermanyFed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, Germany
Becker, Roland
Scholz, Philipp
论文数: 0引用数: 0
h-index: 0
机构:
Fed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, GermanyFed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, Germany
Scholz, Philipp
Jung, Christian
论文数: 0引用数: 0
h-index: 0
机构:
Fed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, GermanyFed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, Germany
Jung, Christian
Weidner, Steffen
论文数: 0引用数: 0
h-index: 0
机构:
Fed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, GermanyFed Inst Mat Res & Testing, Richard Willstatter Str 11, D-12489 Berlin, Germany