Laser ablation in titanium implants followed by biomimetic hydroxyapatite coating: Histomorphometric study in rabbits

被引:28
|
作者
Faeda, Rafael Silveira [1 ]
Spin-Neto, Rubens [2 ]
Marcantonio, Elcio [1 ]
Guastaldi, Antonio Carlos [3 ]
Marcantonio, Elcio, Jr. [2 ]
机构
[1] Araraquara Univ, UNIARA, Dept Postgrad Implantol, Sao Paulo, Brazil
[2] Univ Estadual Paulista, UNESP, Araraquara Dent Sch, Dept Periodontol, Sao Paulo, Brazil
[3] Univ Estadual Paulista, UNESP, Chem Inst Araraquara, Dept Biomat, Sao Paulo, Brazil
关键词
titanium implants; surface modification; hydroxyapatite; laser; EARLY TISSUE-RESPONSE; IN-VIVO; SURFACE MODIFICATION; BONE INTEGRATION; REMOVAL TORQUE; CALCIUM-IONS; PERFORMANCE; OSSEOINTEGRATION; FABRICATION; DEPOSITION;
D O I
10.1002/jemt.22018
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Titanium surface texture and chemistry modification successfully improves the host response and consequently the bone-to-implant contact surrounding dental implants. The aim of the present study was to investigate, using histomorphometrical-analysis, the effects of titanium surface modification by laser-ablation (Nd:YAG) followed by thin chemical deposition of HA. Forty-eight rabbits received one implant by tibiae of AS-machined (MS), laser-modified (LMS), or biomimetic hydroxyapatite-coated (HA) surface. Bone-to-implant contact (BIC) and bone area (BBT) were evaluated after 4, 8, and 12 weeks, at cortical and cancellous regions. Average BIC in the cortical region was higher (P < 0.001) on the LMS and HA implants for all periods, with no differences between LMS and HA. For the cancellous area, the LMS and HA implants showed higher (P < 0.01) BIC than MS at the initial periods. The LMS and HA showed similar values in the cortical region, but a tendency of higher values for HA in the cancellous region was observed in all periods. For the BBT, the differences were found only between HA and MS after 4 weeks in the cortical region (P < 0.05), and after 12 weeks in the cancellous area (P < 0.05). Our results showed that HA biomimetic coating preceded by laser treatment induced the contact osteogenesis and allowed the formation of a more stable boneimplant interface, even in earlier periods. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:940 / 948
页数:9
相关论文
共 50 条
  • [1] Surface and Biomechanical Study of Titanium Implants Modified by Laser With and Without Hydroxyapatite Coating, in Rabbits
    Sisti, Karin E.
    de Rossi, Rafael
    Brochado Antoniolli, Andreia M.
    Aydos, Ricardo D.
    Guastaldi, Antonio C.
    Queiroz, Thallita P.
    Garcia, Idelmo R., Jr.
    Piattelli, Adriano
    Tavares, Hewerson S.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (03) : 231 - 237
  • [2] Biomimetic hydroxyapatite coating on metal implants
    Habibovic, P
    Barrère, F
    van Blitterswijk, CA
    de Groot, K
    Layrolle, P
    [J]. JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2002, 85 (03) : 517 - 522
  • [3] Hydroxyapatite coating of titanium by biomimetic method
    A. Costantini
    G. Luciani
    F. Branda
    L. Ambrosio
    G. Mattogno
    L. Pandolfi
    [J]. Journal of Materials Science: Materials in Medicine, 2002, 13 : 891 - 894
  • [4] Hydroxyapatite coating of titanium by biomimetic method
    Costantini, A
    Luciani, G
    Branda, F
    Ambrosio, L
    Mattogno, G
    Pandolfi, L
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (09) : 891 - 894
  • [5] The Effect of Clopidogrel Treatment on Osseointegration of Titanium Implants: A Histomorphometric Study in Rabbits
    Lillis, Theodoros
    Dabarakis, Nikolaos
    Sakellaridis, Nikolaos
    Fotopoulos, Ioannis
    Tsolakis, Ioannis
    Dailiana, Zoe
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (02) : e1 - e7
  • [6] Electrophoretic coating of hydroxyapatite on titanium implants
    Stoch, A
    Brozek, A
    Kmita, G
    Stoch, J
    Jastrzebski, W
    Rakowska, A
    [J]. JOURNAL OF MOLECULAR STRUCTURE, 2001, 596 : 191 - 200
  • [7] Coating titanium implants with bioglass and with hydroxyapatite A comparative study in sheep
    A. Lopez-Sastre
    J. M. Gonzalo-Orden
    J. A. R. Altónaga
    J. R. Altónaga
    M. A. Orden
    [J]. International Orthopaedics, 1998, 22 : 380 - 383
  • [8] Coating titanium implants with bioglass and with hydroxyapatite -: A comparative study in sheep
    Lopez-Sastre, A
    Gonzalo-Orden, JM
    Altónaga, JAR
    Altónaga, JR
    Orden, MA
    [J]. INTERNATIONAL ORTHOPAEDICS, 1998, 22 (06) : 380 - 383
  • [9] Incorporation of tobramycin into biomimetic hydroxyapatite coating on titanium
    Stigter, M
    de Groot, K
    Layrolle, P
    [J]. BIOMATERIALS, 2002, 23 (20) : 4143 - 4153
  • [10] Formation of Biomimetic Hydroxyapatite Coating on Titanium Plates
    Pylypchuk, Ievgen Volodymyrovych
    Petranovska, Alla Leonidivna
    Turelyk, Margaryta Petrivna
    Gorbyk, Petro Petrovych
    [J]. MATERIALS SCIENCE-MEDZIAGOTYRA, 2014, 20 (03): : 328 - 332