McSART: an iterative model-based, motion-compensated SART algorithm for CBCT reconstruction

被引:15
|
作者
Chee, G. [1 ]
O'Connell, D. [1 ]
Yang, Y. M. [1 ]
Singhrao, K. [1 ]
Low, D. A. [1 ]
Lewis, J. H. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90095 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 09期
关键词
CBCT; motion; lung; model; reconstruction; image; radiation; CONE-BEAM CT; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; RESPIRATORY MOTION; TUMOR MOTION; LUNG; PROJECTION;
D O I
10.1088/1361-6560/ab07d6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
4D cone beam computed tomography (CBCT) images of the thorax and abdomen can have reduced quality due to the limited number of projections per respiratory bin used in gated image reconstruction. In this work, we present a new algorithm to reconstruct high quality CBCT images by simultaneously reconstructing images and generating an associated respiratory motion model. This is done by updating model parameters to compensate for motion during the iterative image reconstruction process. CBCT image acquisition was simulated using the digital eXternal CArdiac Torso (XCAT) phantom, simulating breathing motion using four patient breathing traces. 4DCBCT images were reconstructed using the simultaneous algebraic reconstruction technique (SART), and compared to the proposed motion-compensated SART (McSART) algorithm. McSART used a motion model that describes tissue position as a function of diaphragm amplitude and velocity. The McSART algorithm alternately updated the motion model and image reconstruction, increasing the number of projections used for image reconstruction with every iteration. The model was able to interpolate and extrapolate deformations according to the magnitude of the surrogate signal. Without noise, the final iteration McSART images had HU errors at 31%, 34%, and 44% of their SART-reconstructed counterparts compared to ground truth XCAT images, with corresponding root-mean-square (RMS) motion model errors of 0.75 mm, 1.08 mm, and 1.17 mm respectively. With added image noise, McSART's HU error was 31% of the SART-reconstructed 4DCBCT error, with a 1.43 mm RMS motion model error. Qualitatively, blurring and streaking artifacts were reduced in all the reconstructed images compared to 3D or SART-reconstructed 4DCBCT. The output of the algorithm was a high quality reference image and a corresponding motion model, that could be used to deform the reference image to any other point in a breathing cycle.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Cardiorespiratory motion-compensated micro-CT image reconstruction using an artifact model-based motion estimation
    Brehm, Marcus
    Sawall, Stefan
    Maier, Joscha
    Sauppe, Sebastian
    Kachelriess, Marc
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1948 - 1958
  • [2] GPU based iterative CBCT for prospective motion compensated algorithm for radiation therapy
    Biguri, A.
    Dosanjh, M.
    Hancock, S.
    Soleimani, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S11 - S12
  • [3] REGION-BASED MOTION-COMPENSATED ITERATIVE RECONSTRUCTION TECHNIQUE FOR DYNAMIC COMPUTED TOMOGRAPHY
    Nguyen, Anh-Tuan
    Renders, Jens
    Sijbers, Jan
    De Beenhouwer, Jan
    [J]. 2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [4] An accelerated motion-compensated iterative reconstruction technique for dynamic computed tomography
    Nguyen, A-T
    Renders, J.
    Soete, J.
    Wevers, M.
    Sijbers, J.
    De Beenhouwer, J.
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [5] Iterative Motion-Compensated Reconstruction for Image-Guided Radiation Therapy
    Brehm, Marcus
    Paysan, Pascal
    Oehlhafen, Markus
    Kunz, Patrik
    Kachelriess, Marc
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3839 - 3846
  • [6] Motion-Compensated Reconstruction Method Based on Rigid Motion Model with Multi-Object
    Jin, Xin
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    [J]. Tsinghua Science and Technology, 2010, 15 (01) : 120 - 126
  • [7] Motion-Compensated Reconstruction Method Based on Rigid Motion Model with Multi-Object
    金鑫
    李亮
    陈志强
    张丽
    邢宇翔
    [J]. Tsinghua Science and Technology, 2010, 15 (01) : 120 - 126
  • [8] McSART: An Iteratively Updated Motion-Model and Image Reconstruction Algorithm
    Chee, G.
    Low, D.
    O'Connell, D.
    Singhrao, K.
    Lewis, J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3246 - 3246
  • [9] Motion-compensated TV-reconstruction-based video deinterlacing
    [J]. Trocan, Maria, 1600, Inderscience Enterprises Ltd., 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland (08):
  • [10] PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA
    Ortenberg, A.
    Magnusson, M.
    Sandborg, M.
    Carlsson, G. Alm
    Malusek, A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 405 - 409