Delivery Parameter Variations and Early Clinical Outcomes of Volumetric Modulated Arc Therapy for 31 Prostate Cancer Patients: An Intercomparison of Three Treatment Planning Systems

被引:1
|
作者
Tsutsumi, Shinichi [1 ]
Hosono, Masako N. [1 ]
Tatsumi, Daisaku [2 ]
Miki, Yoshitaka [1 ]
Masuoka, Yutaka [1 ]
Ogino, Ryo [1 ]
Ishii, Kentaro [3 ]
Shimatani, Yasuhiko [1 ]
Miki, Yukio [1 ]
机构
[1] Osaka City Univ, Sch Med, Dept Radiol, Abeno Ku, Osaka 5458585, Japan
[2] Osaka City Univ Hosp, Dept Radiol, Abeno Ku, Osaka 5458585, Japan
[3] Tane Hosp, Nishi Ku, Osaka 5500025, Japan
来源
关键词
RADIOTHERAPY; EXPERIENCE; IMRT; VMAT;
D O I
10.1155/2013/289809
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We created volumetric modulated arc therapy (VMAT) plans for 31 prostate cancer patients using one of three treatment planning systems (TPSs)-ERGO++, Monaco, or Pinnacle-and then treated those patients. A dose of 74 Gy was prescribed to the planning target volume (PTV). The rectum, bladder, and femur were chosen as organs at risk (OARs) with specified dose-volume constraints. Dose volume histograms (DVHs), the mean dose rate, the beam-on time, and early treatment outcomes were evaluated and compared. The DVHs calculated for the three TPSs were comparable.. e mean dose rates and beam-on times for Ergo++, Monaco, and SmartArc were, respectively, 174.3 +/- 17.7, 149.7 +/- 8.4, and 185.8 +/- 15.6 MU/min and 132.7 +/- 8.4, 217.6 +/- 13.1, and 127.5 +/- 27.1 sec. During a follow-up period of 486.2 +/- 289.9 days, local recurrence was not observed, but distant metastasis was observed in a single patient. Adverse events of grade 3 to grade 4 were not observed. The mean dose rate for Monaco was significantly lower than that for ERGO++ and SmartArc (P < 0.0001), and the beam-on time for Monaco was significantly longer than that for ERGO++ and SmartArc (P < 0.0001). Each TPS was successfully used for prostate VMAT planning without significant differences in early clinical outcomes despite significant TPS-specific delivery parameter variations.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Early clinical experience of radiotherapy of prostate cancer with volumetric modulated arc therapy
    Gianfranco A Pesce
    Alessandro Clivio
    Luca Cozzi
    Giorgia Nicolini
    Antonella Richetti
    Emanuela Salati
    Mariacarla Valli
    Eugenio Vanetti
    Antonella Fogliata
    Radiation Oncology, 5
  • [2] Early clinical experience of radiotherapy of prostate cancer with volumetric modulated arc therapy
    Pesce, Gianfranco A.
    Clivio, Alessandro
    Cozzi, Luca
    Nicolini, Giorgia
    Richetti, Antonella
    Salati, Emanuela
    Valli, Mariacarla
    Vanetti, Eugenio
    Fogliata, Antonella
    RADIATION ONCOLOGY, 2010, 5
  • [3] Comparison between two treatment planning systems for volumetric modulated arc therapy optimization for prostate cancer
    Lafond, Caroline
    Gassa, Frederic
    Odin, Christophe
    Drean, Gael
    Even, Justine
    De Crevoisier, Renaud
    Pommier, Pascal
    Manens, Jean-Pierre
    Biston, Marie-Claude
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (01): : 2 - 9
  • [4] Optimal Bladder Volume at Treatment Planning for Prostate Cancer Patients Receiving Volumetric Modulated Arc Therapy
    Fujioka, C.
    Ishii, K.
    Yamanaga, T.
    Ogino, R.
    Kishimoto, S.
    Maehama, T.
    Yamaguchi, T.
    Katayama, S.
    Kawamorita, R.
    Tada, T.
    Nakajima, T.
    Nishimura, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S688 - S689
  • [5] Optimal bladder volume at treatment planning for prostate cancer patients receiving volumetric modulated arc therapy
    Fujioka, Chiaki
    Ishii, Kentaro
    Yamanaga, Toshiko
    Ogino, Ryo
    Kishimoto, Shun
    Kawamorita, Ryu
    Tada, Takuhito
    Nakajima, Toshifumi
    PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) : 395 - 401
  • [6] VOLUMETRIC MODULATED ARC THERAPY: PLANNING AND EVALUATION FOR PROSTATE CANCER CASES
    Zhang, Pengpeng
    Happersett, Laura
    Hunt, Margie
    Jackson, Andrew
    Zelefsky, Michael
    Mageras, Gig
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (05): : 1456 - 1462
  • [7] Comparison of Treatment Planning Systems in Elekta Volumetric Modulated Arc Therapy (Elekta VMAT) - Prostate Cancer Study
    Haga, A.
    Kida, S.
    Okano, Y.
    Itoh, S.
    Matsuura, T.
    Saotome, N.
    Sakumi, A.
    Kotoku, J.
    Kenshiro, S.
    Nakagawa, K.
    Iwai, Y.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Impact of Different Treatment Planning Systems On Modulation Complexity for Prostate Volumetric Modulated Arc Therapy
    Itano, M.
    Motegi, K.
    Kanai, S.
    Shirasaki, S.
    Tachibana, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E283 - E283
  • [9] Dosimetric and Treatment Delivery Parameter Evaluation of Volumetric Modulated Arc Therapy for Retroperitoneal Sarcoma Patients
    Taggar, A.
    Grafe, J.
    Graham, D.
    Kurien, E. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E576 - E576
  • [10] Early Clinical Outcomes in Patients of Carcinoma Cervix Treated With Volumetric Modulated Arc Therapy
    Kombathula, Sri Harsha
    Jagadesan, Pandjatcharam
    Sinnatamby, Mourougan
    Menon, Abhilash
    Kannikanti, Durga Harika
    Chandramouli, R.
    Mathew, John M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)