Experimental Study on Properties of Corroded CFRP Reinforced Concrete Column under Repeating Load

被引:0
|
作者
Hou, Yilie [1 ]
Zhang, Liwei [1 ]
Zhao, Yinghua [1 ]
机构
[1] Dalian Maritime Univ, Inst Rd & Bridge Engn, Dalian, Liaoning, Peoples R China
关键词
CFRP; corrosion resistance; RC column; repeating load; cycle bending load; MTS;
D O I
暂无
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
This paper discusses the use of carbon fiber reinforced polymers (CFRP) wraps as the protection and strengthening techniques for reinforced concrete structures. Four reinforced concrete columns were wrapped with single layer of CFRP sheets before the corrosion initiation. The corrosion was induced by means of an impressed direct current. The properties of the specimen were studied through the different wrapping schemes and corrosion degrees under the axial pressure and cycle bending loads supplied by the material test system (MTS). Results showed that the application of CFRP sheets was efficient in protecting RC columns from corrosion. It was found that the corrosion degree related to the areas of CFRP wraps, while the fatigue life and the ductility of specimens strongly connect with wrapping scheme and corrosion damage.
引用
收藏
页码:407 / 411
页数:5
相关论文
共 50 条
  • [1] Experimental research on ductile behavior of corroded reinforced concrete column confined with CFRP
    Li, Jin-Bo
    Gong, Jin-Xin
    Dalian Ligong Daxue Xuebao/Journal of Dalian University of Technology, 2010, 50 (02): : 220 - 227
  • [2] Experimental study on seismic behavior of corroded reinforced concrete columns strengthened with concrete jacket and CFRP
    Li, Jinbo
    Gong, Jinxin
    Wang, Lihuan
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2009, 42 (04): : 17 - 26
  • [3] Experimental Study on the Shear Properties of Concrete Column Repaired by CFRP
    Cui, Xiguang
    Wang, Zhiwei
    Ma, Nan
    Yu, Zhonglong
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 1598 - 1602
  • [4] Experimental study on reinforced concrete corroded columns under loading condition
    Rani, M. Usha
    Subramanian, K.
    BULLETIN OF ELECTROCHEMISTRY, 2006, 22 (06): : 263 - 268
  • [5] Experimental study on PVC-CFRP confined reinforced concrete short column under axial compression
    Yu, Feng
    Niu, Ditao
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (06): : 129 - 136
  • [6] The Experimental Study on Fatigue Properties of CFRP Reinforced Concrete Beam
    Li, Ziqi
    Fan, Yanyan
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3157 - 3161
  • [7] Experimental study on seismic behavior of corroded reinforced concrete column wrapped with PET sheet
    Zhang, Chuang
    Zhang, Dawei
    Zhao, Yuxi
    Duan, An
    Chen, Ju
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 209 - 215
  • [8] Experimental study on bond behavior of corroded reinforced concrete under coupling effect of fatigue load and elevated temperature
    Liu, Caiwei
    Liu, Xinyu
    Yan, Liangtai
    Zheng, Chunying
    ENGINEERING FAILURE ANALYSIS, 2024, 166
  • [9] Behaviour of corroded reinforced concrete beams repaired with NSM CFRP rods, experimental and finite element study
    Almassri, Belal
    Al Mahmoud, Firas
    Francois, Raoul
    COMPOSITES PART B-ENGINEERING, 2016, 92 : 477 - 488
  • [10] Experimental study of the strength and deformations of carbon fibre reinforced polymer (CFRP) retrofitted reinforced concrete slabs under blast load
    Razaqpur, A. Ghani
    Contestabile, Ettore
    Tolba, Ahmed
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2009, 36 (08) : 1366 - 1377