Wireless pH Recording Immediately Above the Squamocolumnar Junction Improves the Diagnostic Performance of Esophageal pH Studies

被引:17
|
作者
Wenner, Jorgen [1 ]
Hall, Mats [2 ]
Hoglund, Peter [3 ]
Johansson, Jan [1 ]
Johnsson, Folke [1 ]
Oberg, Stefan [1 ]
机构
[1] Univ Lund Hosp, Dept Surg, SE-22185 Lund, Sweden
[2] Univ Lund Hosp, Dept Med, SE-22185 Lund, Sweden
[3] Univ Lund Hosp, Competence Ctr Clin Res, SE-22185 Lund, Sweden
来源
AMERICAN JOURNAL OF GASTROENTEROLOGY | 2008年 / 103卷 / 12期
关键词
D O I
10.1111/j.1572-0241.2008.02174.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: The optimal position for pH electrode placement in the diagnosis of gastroesophageal reflux disease (GERD) is unknown. The aim of this study was to evaluate the discriminatory power of targeted pH recording immediately above the squamocolumnar junction (SCJ) and to compare the results with those obtained by simultaneous recording at the conventional level for pH monitoring. SUBJECTS AND METHODS: Sixty-two patients with typical reflux symptoms and 49 asymptomatic volunteers underwent 48-h simultaneous wireless pH monitoring with two endoscopically placed pH recording capsules, one immediately above the SCJ and one at the traditional position, 6 cm above the SCJ. The diagnostic accuracy, sensitivity, and specificity of pH monitoring at the two levels were analyzed using receiver operating characteristics (ROC) curves. RESULTS: Of the 62 patients (39 men and 23 women, median age 48 yrs), 32 patients had erosive esophagitis and 30 had no endoscopic evidence of mucosal injury. Analysis of the area under the ROC curve (AUC) indicated that the total percent time with pH < 4 for the entire 48-h period was the parameter that best distinguished GERD patients from controls. pH monitoring performed directly above the SCJ significantly increased the number of patients correctly classified with GERD compared to standard electrode placement. With a predefined test specificity of 90%, pH monitoring immediately above the SCJ increased the sensitivity of the test from 63% to 86% in all patients, from 78% to 97% in patients with esophagitis and from 47% to 73% in patients with no esophagitis. CONCLUSIONS: Compared to standard electrode placement, wireless pH recording immediately above the SCJ improved the diagnostic performance of esophageal pH monitoring in patients with GERD. (Am J Gastroenterol 2008;103:2977-2985).
引用
收藏
页码:2977 / 2985
页数:9
相关论文
共 20 条
  • [1] Acid reflux immediately above the squamocolumnar junction and in the distal esophagus:: Simultaneous pH monitoring using the wireless capsule pH system
    Wenner, Jorgen
    Johnsson, Folke
    Johansson, Jan
    Oberg, Stefan
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (08): : 1734 - 1741
  • [2] The postprandial acid pocket does not extend into most distal esophagus: evidence from pH studies performed immediately above the squamocolumnar junction
    Hall, Mats
    Wenner, Jorgen
    Oberg, Stefan
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2014, 49 (01) : 15 - 22
  • [3] Comparison of esophageal acid exposure at 1 cm and 6 cm above the squamocolumnar junction using the Bravo™ pH monitoring system
    Pandolfino, JE
    Lee, TJ
    Schreiner, MA
    Zhang, Q
    Roth, MP
    Kahrilas, PJ
    DISEASES OF THE ESOPHAGUS, 2006, 19 (03) : 177 - 182
  • [4] Studies of acid exposure immediately above the gastro-oesophageal squamocolumnar junction: evidence of short segment reflux
    Fletcher, J
    Wirz, A
    Henry, E
    McColl, KEL
    GUT, 2004, 53 (02) : 168 - 173
  • [6] Diagnostic Performance of Esophageal pH Electrodes at Different Locations
    Gardner, Jerry D.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2009, 104 (06): : 1601 - 1601
  • [7] 48 Hour BRAVO (Wireless) Esophageal pH Monitoring Improves Symptom Correlation as Compared to 24 Hour Studies Alone
    Chander, Bani
    Hanley-Williams, Nicole
    Deng, Yanhong
    Sheth, Anish A.
    GASTROENTEROLOGY, 2011, 140 (05) : S251 - S251
  • [8] ASSESSMENT OF ESOPHAGEAL MOTILITY WITH INTRALUMINAL PH STUDIES A DIAGNOSTIC TOOL IN REFLUX ESOPHAGITIS
    RIORDAN, N
    DOYLE, JS
    IRISH JOURNAL OF MEDICAL SCIENCE, 1976, 145 (02) : 63 - 64
  • [9] Recording Accuracy of a New ISFET Disposable Catheter pH Electrode Design Compared to a "Gold Standard" Glass pH Catheter in Ambulatory Esophageal pH Monitoring Studies
    Fareeduddin, Anita
    Kahrilas, Peter J.
    Pandolfino, John E.
    Parks, Thomas R.
    Luger, Daniel
    Kwiatek, Monika A.
    GASTROENTEROLOGY, 2009, 136 (05) : A289 - A290
  • [10] Utilization of wireless pH monitoring technologies: a summary of the proceedings from the Esophageal Diagnostic Working Group
    Richter, J. E.
    Pandolfino, J. E.
    Vela, M. F.
    Kahrilas, P. J.
    Lacy, B. E.
    Ganz, R.
    Dengler, W.
    Oelschlager, B. K.
    Peters, J.
    DeVault, K. R.
    Fass, R.
    Gyawali, C. P.
    Conklin, J.
    DeMeester, T.
    DISEASES OF THE ESOPHAGUS, 2013, 26 (08): : 755 - 765