Therapeutic hypothermia and myocardium in perinatal asphyxia: a microvolt T-wave alternans and Doppler echocardiography study

被引:0
|
作者
Karpuz, D. [1 ]
Celik, Y. [2 ]
Giray, D. [1 ]
Tasdelen, B. [3 ]
Hallioglu, O. [1 ]
机构
[1] Mersin Univ, Fac Med, Dept Pediat, Div Pediat Cardiol, 34 Cadde,Ciftlikkoy Kampusu, TR-33343 Mersin, Turkey
[2] Mersin Univ, Fac Med, Dept Pediat, Div Neonatol, Mersin, Turkey
[3] Mersin Univ, Dept Biostat, Fac Med, Mersin, Turkey
关键词
hypoxic-ischemic encephalopathy; microvolt T-wave alternans; therapeutic hypothermia; tissue Doppler; HYPOXIC-ISCHEMIC ENCEPHALOPATHY; BLOOD-FLOW; DYSFUNCTION; INFANTS; SOCIETY; UTILITY; HOLTER;
D O I
10.4149/BLL_2017_144
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This is the first study evaluating the predictive value of myocardial performance on arrhythmia and mortality via tissue-Doppler and microvolt T-wave alternans in infants with hypoxic-ischemic encephalopathy treated with therapeutic hypothermia-rewarming. METHODS: The study included 23 term newborns having criteria for hypoxic-ischemic encephalopathy, and 12 controls. Tissue-Doppler imaging and T-wave alternans were performed in the first six hours after birth in patients from both groups and after hypothermia-rewarming treatment on the fifth day. RESULTS: The basal T-wave alternans values were higher in patients in lead aVF(p < 0.001) which also correlated with existing acidemia (r = 0.517; p = 0.012). Basal T-wave alternans and post-treatment values of patients were compared in leads V1 (p < 0.001) and aVF (p < 0.001); a significant decrease was found on the fifth day. Moreover, right ventricle diastolic diameter and estimated systolic pulmonary artery pressure of patients in the first 6 hours were higher (p = 0.03, p < 0.001, respectively). Although, the ejection fraction of patients did not decrease, basal values of left and right ventricular systolic and diastolic functions were lower initially, and increased significantly after treatment. CONCLUSION: The global cardiac functions and myocardial performance of newborns with hypoxic-ischemia might be improved with therapeutic hypothermia which can be determined by using T-wave alternans and tissue-Doppler measurements. However, further studies are needed to assess whether these measurements are prognostic in determining the myocardial dysfunction and arrhythmias (Tab. 2, Fig. 3, Ref. 26). Text in PDF www.elis.sk.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 50 条
  • [1] The microvolt T-wave alternans test
    Gormez, Selcuk
    Erciyes, Demet
    Gulbaran, Murat
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2010, 38 (06): : 436 - 443
  • [2] Microvolt T-wave alternans and ICD
    Chen, PS
    HEART RHYTHM, 2005, 2 (01) : 114 - 114
  • [3] Microvolt T-wave alternans in ischemic cardiomyopathy
    Madias, John E.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 162 (02) : 135 - 136
  • [4] Scar tissue and microvolt T-wave alternans
    Karin Kraaier
    Marlon A. G. M. Olimulder
    Michel A. Galjee
    Pascal F. H. M. van Dessel
    Job van der Palen
    Arthur A. M. Wilde
    Marcoen F. Scholten
    The International Journal of Cardiovascular Imaging, 2014, 30 : 773 - 779
  • [5] Scar tissue and microvolt T-wave alternans
    Kraaier, Karin
    Olimulder, Marlon A. G. M.
    Galjee, Michel A.
    van Dessel, Pascal F. H. M.
    van der Palen, Job
    Wilde, Arthur A. M.
    Scholten, Marcoen F.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (04): : 773 - 779
  • [6] Clinical significance of microvolt T-wave alternans
    Klingenheben T.
    Ptaszynski P.
    Herzschrittmachertherapie & Elektrophysiologie, 2007, 18 (1): : 39 - 44
  • [7] Microvolt T-wave alternans in Chagas disease
    Raadschilders, Lotte
    Barbosa, Marco Paulo T.
    Carmo, Andre Assis
    Nouwen, Jan L.
    Costa Rocha, Manoel Otavio
    Ribeiro, Antonio Luiz P.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 187 : 7 - 8
  • [8] Microvolt T-wave alternans in the SCD-HeFT study
    Estes, N. A. Mark, III
    HEART RHYTHM, 2009, 6 (02) : 293 - 293
  • [9] Microvolt T-Wave Alternans in Short QT Syndrome
    Maury, Philippe
    Extramiana, Fabrice
    Giustetto, Carla
    Cardin, Cristelle
    Rollin, Anne
    Duparc, Alexandre
    Mondoly, Pierre
    Denjoy, Isabelle
    Delay, Marc
    Messali, Anne
    Leenhardt, Antoine
    Marangoni, Daniele
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (12): : 1413 - 1419
  • [10] The Use of Microvolt T-Wave Alternans in Chagas Disease
    Pastore, Carlos Alberto
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2018, 110 (05) : 418 - 419