Impact on Thermal Energy Needs Caused by the Use of Different Solar Irradiance Decomposition and Transposition Models: Application of EN ISO 52016-1 and EN ISO 52010-1 Standards for Five European Cities

被引:6
|
作者
Summa, Serena [1 ]
Remia, Giada [1 ]
Sebastianelli, Ambra [1 ]
Coccia, Gianluca [1 ]
Di Perna, Costanzo [1 ]
机构
[1] Univ Politecn Marche, Ind Engn & Math Sci Dept, Via Brecce Bianche 1, I-60131 Ancona, Italy
关键词
EN ISO 52016-1; EN ISO 52010-1; solar irradiance decomposition and trasposition models; climate data; building simulation; building energy performance; DIFFUSE; INSOLATION; FRACTION;
D O I
10.3390/en15238904
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To solve the series of heat balances that EN ISO 52016-1 uses to simulate the dynamic hourly energy requirements of a building, detailed climatic data are required as input. Differently from air temperatures, relative humidity and wind speed, which are easily measurable and available in databases, the direct and diffuse solar irradiances incident on the different inclined and oriented surfaces, which are fundamental for the evaluation of solar gains, must be estimated using one of the many regression models available in the literature. Therefore, in this work, the energy needs of buildings were evaluated with the simplified hourly dynamic method of EN ISO 52016-1 by varying the solar irradiance sets on inclined and oriented surfaces obtained from EN ISO 52010-1 and three other pairs of solar irradiance separation and transposition models. Five European locations and two different window solar transmission coefficients (g(gl)) were analysed. The results showed that on average, for the heating period and for both g(gl), the use of the different methods causes an average error on the calculation of the annual demand of less or slightly more than 5%; while for the cooling period, the average error on the calculation of the annual demand is 16.4% for the case study with g(gl) = 0.28 and 25.1% for the case study with g(gl) = 0.63. On the other hand, analysing the root-mean-square-error of the hourly data, using the model contained in TRNSYS as a benchmark, for most of the cases, when varying window orientations, cities and g(gl), the model that diverges furthest from the others is that contained in EN ISO 52010-1.
引用
收藏
页数:18
相关论文
共 2 条
  • [1] The application of EN ISO 52016-1 to assess building cost-optimal energy performance levels in Italy
    Degerfeld, Franz Bianco Mauthe
    Piro, Matteo
    De Luca, Giovanna
    Ballarini, Ilaria
    Corrado, Vincenzo
    ENERGY REPORTS, 2023, 10 : 1702 - 1717
  • [2] EN ISO 52016-1: The New International Standard To Calculate Building Energy Needs for Heating And Cooling, Internal Temperatures And Heating And Cooling Load
    van Dijk, Dick
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 4061 - 4068