Application of the blackbody radiation source for characteristics measurement of submillimeter low-temperature direct detectors

被引:7
|
作者
Vystavkin, AN
Pestriakov, AV
Vinogradov, EA
机构
[1] Russian Acad Sci, Inst Radioengn & Elect, Moscow 125009, Russia
[2] Russian Acad Sci, Inst Spect, Troitsk 142092, Russia
关键词
submillimeter waves; direct detectors; characterization; blackbody;
D O I
10.1016/j.nima.2005.12.055
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As is well-known characteristics measurement of submillimeter low-temperature direct detectors can be fulfilled using their signal response for the radiation of temperature swept blackbody. We describe a method using the Fredholm integral equation of first kind which solution gives possibility to derive direct detector spectral characteristic from the signal response dependence on temperature with acceptable accuracy. Then a noise equivalent power of detector can be determined as well. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:570 / 572
页数:3
相关论文
共 50 条
  • [1] MEASUREMENT OF SPECTRUM OF SUBMILLIMETER COSMIC BLACKBODY RADIATION
    RICHARDS, PL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 540 - 540
  • [2] A low-temperature blackbody reference source to -40°C
    Chu, B
    Machin, G
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (01) : 1 - 6
  • [3] LOW-TEMPERATURE BLACKBODY
    PAVLYUKOV, AK
    KHOLOPOV, GK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (03) : 854 - 855
  • [4] Uncertainties in blackbody corrections for low-temperature radiation thermometers
    Saunders, P.
    Manoi, A.
    METROLOGIA, 2020, 57 (02)
  • [5] Characteristics measurements of supersensitive low temperature direct detector receivers of submillimeter waveband region using planck radiation source
    Vystavkin, AN
    Pestriakov, AV
    Vinogradov, EA
    MSMW'04: FIFTH INTERNATIONAL KHARKOV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER, AND SUBMILLIMETER WAVES, SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2004, : 595 - 597
  • [6] Calibration and application of radiometer for low-temperature infrared radiation source
    Shi, Qingfeng
    Gao, Yanze
    Li, Zhuo
    Shi, Rui
    AOPC 2021: INFRARED DEVICE AND INFRARED TECHNOLOGY, 2021, 12061
  • [7] Applications of low-temperature detectors to synchrotron radiation
    d'Acapito, F
    Maurizio, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 602 - 605
  • [8] LOW-TEMPERATURE BEHAVIOR OF BLACKBODY RADIATION ENERGY IN INFINITE SLAB RESONATOR
    ECKHARDT, W
    PHYSICS LETTERS A, 1977, 62 (06) : 386 - 388
  • [9] Effect of low-temperature annealing on characteristics of SiC detectors with radiation-induced defects
    A. M. Ivanov
    N. B. Strokan
    A. V. Sadokhin
    A. A. Lebedev
    Semiconductors, 2007, 41 : 979 - 983
  • [10] Effect of low-temperature annealing on characteristics of SiC detectors with radiation-induced defects
    Ivanov, A. M.
    Strokan, N. B.
    Sadokhin, A. V.
    Lebedev, A. A.
    SEMICONDUCTORS, 2007, 41 (08) : 979 - 983