Influence of mode conversions in the skull on transcranial focused ultrasound and temperature fields utilizing the wave field separation method: A numerical study

被引:9
|
作者
Wang, Xiang-Da [1 ,2 ]
Lin, Wei-Jun [1 ]
Su, Chang [1 ]
Wang, Xiu-Ming [1 ]
机构
[1] Chinese Acad Sci, Inst Acoust, State Key Lab Acoust, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
transcranial focused ultrasound; temperature rise; mode conversion; wave field separation; BLOOD-BRAIN-BARRIER; PERFECTLY MATCHED LAYER; FUNCTIONAL NEUROSURGERY; HETEROGENEOUS MEDIA; PHASED-ARRAY; PROPAGATION; ABSORPTION; SIMULATION; SURGERY; BONE;
D O I
10.1088/1674-1056/27/2/024302
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Transcranial focused ultrasound is a booming noninvasive therapy for brain stimuli. The Kelvin-Voigt equations are employed to calculate the sound field created by focusing a 256-element planar phased array through a monkey skull with the time-reversal method. Mode conversions between compressional and shear waves exist in the skull. Therefore, the wave field separation method is introduced to calculate the contributions of the two waves to the acoustic intensity and the heat source, respectively. The Pennes equation is used to depict the temperature field induced by ultrasound. Five computational models with the same incident angle of 0 degrees and different distances from the focus for the skull and three computational models at different incident angles and the same distance from the focus for the skull are studied. Numerical results indicate that for all computational models, the acoustic intensity at the focus with mode conversions is 12.05% less than that without mode conversions on average. For the temperature rise, this percentage is 12.02%. Besides, an underestimation of both the acoustic intensity and the temperature rise in the skull tends to occur if mode conversions are ignored. However, if the incident angle exceeds 30 degrees, the rules of the over-and under-estimation may be reversed. Moreover, shear waves contribute 20.54% of the acoustic intensity and 20.74% of the temperature rise in the skull on average for all computational models. The percentage of the temperature rise in the skull from shear waves declines with the increase of the duration of the ultrasound.
引用
收藏
页数:14
相关论文
共 8 条
  • [1] Influence of mode conversions in the skull on transcranial focused ultrasound and temperature fields utilizing the wave field separation method: A numerical study
    王祥达
    林伟军
    苏畅
    王秀明
    ChinesePhysicsB, 2018, 27 (02) : 405 - 418
  • [2] A numerical study of pulsed sonication for reducing thermal deposition in the skull during transcranial focused ultrasound surgery
    Yin, XT
    Hynynen, K
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1241 - 1244
  • [3] A 200-1380-kHz Quadrifrequency Focused Ultrasound Transducer for Neurostimulation in Rodents and Primates: Transcranial In Vitro Calibration and Numerical Study of the Influence of Skull Cavity
    Constans, Charlotte
    Deffieux, Thomas
    Pouget, Pierre
    Tanter, Mickael
    Aubry, Jean-Francois
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (04) : 717 - 724
  • [4] Numerical Study of Nonlinear, Transcranial Focused Ultrasound Wave Propagation for Blood-Brain Barrier (BBB) Opening
    Jimenez, Noe
    Roig, Bernardino
    Redondo, Javier
    Pico, Ruben
    Marquet, Fabrice
    Konofagou, Elisa E.
    Camarena, Francisco
    11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 155 - 161
  • [5] Influence of the skull bone and brain tissue on the sound field in transcranial extracorporeal shock wave therapy: an ex vivo study
    Reinhardt, Nina
    Schmitz, Christoph
    Milz, Stefan
    de la Fuente, Matias
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024, 69 (01): : 27 - 37
  • [6] A 200-1380 kHz Quadrifrequency Focused Ultrasound Transducer for Neurostimulation in Rodents and Primates: Transcranial In Vitro Calibration and Numerical Study of the Influence of Skull Cavity (vol 64, pg 717, 2017)
    Constans, Charlotte
    Deffieux, Thomas
    Pouget, Pierre
    Tanter, Mickael
    Aubry, Jean-Francois
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (09) : 1417 - 1417
  • [7] Investigation of Standing-Wave Formation in a Human Skull for a Clinical Prototype of a Large-Aperture, Transcranial MR-Guided Focused Ultrasound (MRgFUS) Phased Array: An Experimental and Simulation Study
    Song, Junho
    Pulkkinen, Aki
    Huang, Yuexi
    Hynynen, Kullervo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (02) : 435 - 444
  • [8] Study on influence of computational grid resolution in numerical simulation of unsteady flow that targets flow field around a roof: Fundamental study on prediction method of separation flow around building (Part 2)
    Yamada S.
    Yamanaka T.
    Journal of Environmental Engineering (Japan), 2019, 84 (756): : 179 - 186