EFFECT OF VENC ON ACCURACY OF VELOCITY PROFILES IN MULTI-SLICE PHASE-CONTRAST MR IMAGING OF STENOTIC FLOW

被引:0
|
作者
Negahdar, M. J. [1 ]
Cha, J. [1 ]
Shakeri, M. [2 ]
Kendrick, M. [4 ]
Alshaher, M. [4 ]
Khodarahimi, I. [1 ]
Sharp, M. K. [2 ]
Yancey, A.
Heidenreich, J. [3 ]
Amini, A. [1 ]
机构
[1] Univ Louisville, Dept Elect & Comp Engn, Med Imaging Lab, Louisville, KY 40292 USA
[2] Univ Louisville, Dept Mech Engn, Biofluid Mech Lab, Louisville, KY USA
[3] Univ Louisville, Dept Radiol, Louisville, KY USA
[4] Univ Louisville, Robley Rex VA Med Ctr, Louisville, KY USA
来源
2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI) | 2012年
基金
美国国家科学基金会;
关键词
Phase-Contrast MRI; Computational fluid dynamics; V-enc; Atherosclerotic Disease; phase unwrapping;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phase-contrast MRI (PC MRI) is a powerful technique for imaging the flow velocities in-vivo. In PC MRI, the velocity encoding parameter, V-enc, plays a central role in fidelity of velocities acquired with this technique. Typically V-enc is chosen to be the highest velocity in the flow. However, when acquiring velocity images at a number of slice locations, it may be advantageous to change the V-enc as a function of position. The goal of this study was to determine the effect of V-enc on the accuracy of the estimated velocity profiles in a range of locations in a phantom model of a 90% area stenosis. To this end, velocities from PC MRI were compared with velocities from computational fluid dynamics (CFD) simulations for identical geometry and flow conditions. Our results confirm that although using smaller V-enc velocity profiles. However, there is a lower limit to setting the V-enc, beyond which phase-unwrapping becomes uncertain.
引用
收藏
页码:820 / 823
页数:4
相关论文
共 50 条
  • [1] Simultaneous Multi-VENC and Simultaneous Multi-Slice Phase Contrast Magnetic Resonance Imaging
    Park, Suhyung
    Chen, Liyong
    Townsend, Jennifer
    Lee, Hyunyeol
    Feinberg, David A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (03) : 742 - 752
  • [2] Accuracy and Reproducibility of Phase-Contrast MR Imaging Measurements for CSF Flow
    Wentland, A. L.
    Wieben, O.
    Korosec, F. R.
    Haughton, V. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (07) : 1331 - 1336
  • [3] ACCURACY OF MR PHASE-CONTRAST VELOCITY-MEASUREMENTS FOR UNSTEADY-FLOW
    FRAYNE, R
    STEINMAN, DA
    ETHIER, CR
    RUTT, BK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04): : 428 - 431
  • [4] MR PHASE-CONTRAST IMAGING - DETERMINATION OF FLOW VELOCITY AND FLOW PROFILE IN INTRACRANIAL-ARTERIES
    WENTZ, KU
    DIEHL, RR
    HENKES, H
    BLUM, K
    BELLENBERG, B
    MULLER, E
    RADIOLOGE, 1994, 34 (04): : 212 - 220
  • [5] Simultaneous wall and blood-flow phase-contrast imaging using a single low VENC
    Junmin Liu
    James A White
    Maria Drangova
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [6] Comparison of Phase-Contrast MR Imaging and Endovascular Sonography for Intracranial Blood Flow Velocity Measurements
    Schneiders, J. J.
    Ferns, S. P.
    van Ooij, P.
    Siebes, M.
    Nederveen, A. J.
    van den Berg, R.
    van Lieshout, J.
    Jansen, G.
    vanBavel, E.
    Majoie, C. B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (09) : 1786 - 1790
  • [7] Peak velocity and flow quantification validation for sensitivity-encoded phase-contrast MR imaging
    Lew, Calvin D.
    Alley, Marcus T.
    Bammer, Roland
    Spielman, Daniel M.
    Chan, Frandics P.
    ACADEMIC RADIOLOGY, 2007, 14 (03) : 258 - 269
  • [8] Regularization of flow streamlines in multislice phase-contrast MR imaging
    Fatouraee, N
    Amini, AA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (06) : 699 - 709
  • [9] Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    Peter D. Gatehouse
    Jennifer Keegan
    Lindsey A. Crowe
    Sharmeen Masood
    Raad H. Mohiaddin
    Karl-Friedrich Kreitner
    David N. Firmin
    European Radiology, 2005, 15 : 2172 - 2184
  • [10] Applications of phase-contrast flow and velocity imaging in cardiovascular MRI
    Gatehouse, PD
    Keegan, J
    Crowe, LA
    Masood, S
    Mohiaddin, RH
    Kreitner, KF
    Firmin, DN
    EUROPEAN RADIOLOGY, 2005, 15 (10) : 2172 - 2184