Simultaneous dual-isotope imaging based on an artificial neural network for evaluating myocardial perfusion and fatty acid metabolism

被引:6
|
作者
Hashimoto, Jun [1 ,2 ]
Ogawa, Koichi [3 ]
Bai, Jingming [2 ,4 ]
Kubo, Atsushi [2 ]
Imai, Yutaka [1 ]
机构
[1] Tokai Univ, Sch Med, Dept Radiol, Isehara, Kanagawa 2591193, Japan
[2] Keio Univ, Tokyo, Japan
[3] Hosei Univ, Fac Sci & Engn, Dept Elect Informat, Tokyo, Japan
[4] Ageo Cent Gen Hosp, Dept Internal Med, Ageo, Japan
关键词
Myocardial perfusion imaging: SPECT; BMIPP; dual-isotope imaging; SCATTER; SPECT; COMPENSATION; TL-201; QUANTITATION; ATTENUATION;
D O I
10.1007/s12350-013-9699-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We contrived a scatter correction method based on an artificial neural network (ANN) and applied it to the simultaneous evaluation of myocardial perfusion and fatty acid metabolism in single-photon emission computed tomography (SPECT). The count data of three energy windows were used as inputs of the ANN. The count ratios of the estimated primary-to-total photons for Tc-99m and I-123, which were used to reconstruct Tc-99m and I-123 images, were calculated using the ANN. In a phantom study, single- and dual-isotope imaging with Tc-99m/I-123 and Tl-201/I-123 was performed by means of a cardiac phantom simulating patients with and without obesity. In a human study, five normal volunteers and ten patients with myocardial infarction underwent myocardial perfusion and fatty acid metabolism imaging with single and dual SPECT with combinations of Tc-99m-methoxyisobutylisonitrile/I-123-beta-methyl(p-iodophenyl)pentadecanoic acid (BMIPP) and Tl-201/I-123-BMIPP as tracers. Technetium-99m yielded more homogeneous images than Tl-201 because of the lower degree of photon attenuation, especially in the condition of obese patients, resulting in clearer visualization of the perfusion-metabolism mismatch. Dual Tc-99m/I-123 SPECT offered comparable images with single SPECT in assessing myocardial damage. The method effectively separated Tc-99m and I-123 primary photons and proved applicable to Tc-99m/I-123 dual-isotope myocardial SPECT.
引用
收藏
页码:396 / 405
页数:10
相关论文
共 50 条
  • [1] Simultaneous dual-isotope imaging based on an artificial neural network for evaluating myocardial perfusion and fatty acid metabolism
    Jun Hashimoto
    Koichi Ogawa
    Jingming Bai
    Atsushi Kubo
    Yutaka Imai
    Journal of Nuclear Cardiology, 2013, 20 : 396 - 405
  • [2] A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism
    Ko, Toshiyuki
    Utanohara, Yuko
    Suzuki, Yasuhiro
    Kurihara, Makiko
    Iguchi, Nobuo
    Umemura, Jun
    Sumiyoshi, Tetsuya
    Tomoike, Hitonobu
    HEART AND VESSELS, 2016, 31 (01) : 38 - 45
  • [3] A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism
    Toshiyuki Ko
    Yuko Utanohara
    Yasuhiro Suzuki
    Makiko Kurihara
    Nobuo Iguchi
    Jun Umemura
    Tetsuya Sumiyoshi
    Hitonobu Tomoike
    Heart and Vessels, 2016, 31 : 38 - 45
  • [4] An iterative dual-isotope method for simultaneous imaging of myocardial viability and perfusion
    Celler, A. M.
    Shcherbinin, S.
    Trummer, M.
    Cohen, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S217 - S217
  • [5] Dual-isotope myocardial perfusion SPECT imaging: Past, present, and future
    Tali Sharir
    Piotr Slomka
    Journal of Nuclear Cardiology, 2018, 25 : 2024 - 2028
  • [6] Dual-isotope myocardial perfusion SPECT imaging: Past, present, and future
    Sharir, Tali
    Slomka, Piotr
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (06) : 2024 - 2028
  • [7] Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast ...
    Henzlova, Milena J.
    Duvall, W. Lane
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (03) : 523 - 525
  • [8] Return of dual-isotope SPECT myocardial perfusion imaging? Not so fast…
    Milena J. Henzlova
    W. Lane Duvall
    Journal of Nuclear Cardiology, 2015, 22 : 523 - 525
  • [9] Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging
    Bai, Jingming
    Hashimoto, Jun
    Ogawa, Koichi
    Nakahara, Tadaki
    Suzuki, Takayuki
    Kubo, Atsushi
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (01) : 25 - 32
  • [10] Scatter correction based on an artificial neural network for99mTc and123I dual-isotope SPECT in myocardial and brain imaging
    Jingming Bai
    Jun Hashimoto
    Koichi Ogawa
    Tadaki Nakahara
    Takayuki Suzuki
    Atsushi Kubo
    Annals of Nuclear Medicine, 2007, 21