Locking versus standard screw fixation for acetabular cups: is there a difference?

被引:9
|
作者
Heller, Snir [1 ]
Brosh, Tamar [2 ]
Kosashvili, Yona [1 ]
Velkes, Steven [1 ]
Burg, Alon [1 ]
Dudkiewicz, Israel [3 ]
机构
[1] Rabin Med Ctr, Dept Orthoped Surg, Petah Tiqwa, Israel
[2] Tel Aviv Univ, Dept Oral Rehabil, IL-69978 Tel Aviv, Israel
[3] Tel Aviv Med Ctr & Sch Med, Dept Rehabil, Tel Aviv, Israel
关键词
Cementless total hip replacement; Acetabular primary fixation; Locking screws; INITIAL STABILITY; ECCENTRICITY; BONE;
D O I
10.1007/s00402-013-1709-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Total hip replacement has been established as a valid treatment option for displaced subcapital fractures. However, insufficient primary fixation may be the reason for early loosening in these osteoporotic patients. Primary fixation of the cup is usually achieved by press-fit fixation that can be enhanced using screws. Locking the screws into their respective cups may seem to improve the primary fixation of the construct, as locked plates proved superior fixation for osteoporotic fractures. The study consisted of three groups: in each group, three cups were fixed into blocks of foam bone using press-fit technique. In the first group, no additional screws were used, in the second group two standard screws were inserted, while in the third group two acetabular screws were cemented into the cup to simulate locked screw fixation. Load was applied onto the rim of the acetabular component to cause shearing between the cup and the block. Cup fixation was examined by a loading machine that acquired load versus displacement. The stiffness (load vs. displacement) was calculated. Screws, either locked or non-locked, enhanced cup fixation by 26 % (p value < 0.01). No significant changes were found between the locking and non-locking screws groups. These experimental results indicate that acetabular screws enhance primary cup fixation. This may become significant in conditions where the acetabular bone stock is suboptimal, such as when performing total hip arthroplasty after displaced subcapital fractures. However, there is no superiority for locked screws over standard screw fixation.
引用
收藏
页码:701 / 705
页数:5
相关论文
共 50 条
  • [1] Locking versus standard screw fixation for acetabular cups: is there a difference?
    Snir Heller
    Tamar Brosh
    Yona Kosashvili
    Steven Velkes
    Alon Burg
    Israel Dudkiewicz
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 701 - 705
  • [2] Medial Locking Plate Versus Screw Fixation for Fixation of the Ludloff Osteotomy
    Saxena, Amol
    St Louis, Marie
    JOURNAL OF FOOT & ANKLE SURGERY, 2013, 52 (02): : 153 - 157
  • [3] A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation
    Mehin, Ramin
    Jones, Bryn
    Zhu, Qingan
    Broekhuyse, Henry
    CANADIAN JOURNAL OF SURGERY, 2009, 52 (03) : 221 - 228
  • [4] Screw fixation of acetabular fractures
    U. Stöckle
    R. Hoffmann
    M. Nittinger
    N. P. Südkamp
    N. P. Haas
    International Orthopaedics, 2000, 24 : 143 - 147
  • [5] Screw fixation of acetabular fractures
    Stöckle, U
    Hoffmann, R
    Nittinger, M
    Südkamp, NP
    Haas, NP
    INTERNATIONAL ORTHOPAEDICS, 2000, 24 (03) : 143 - 147
  • [6] Initial stability of cementless acetabular cups: press-fit and screw fixation interaction—an in vitro biomechanical study
    Tabata T.
    Kaku N.
    Hara K.
    Tsumura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (3) : 497 - 502
  • [7] Locking plate fixation of humeral head fractures with a telescoping screw. A comparative biomechanical study versus a standard plate
    Gradl, Gertraud
    Stedtfeld, Hans-Werner
    Morlock, Michael
    Sellenschloh, Kay
    Pueschel, Klaus
    Mittlmeier, Thomas
    Gradl, Georg
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 734 - 738
  • [8] Locking Plate Fixation for Canine Acetabular Fractures
    Piana, Francesco
    Solano, Miguel
    Kalff, Stephen
    Yeadon, Russell
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (04) : 294 - 300
  • [9] Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate
    Mardani-Kivi, Mohsen
    Mirbolook, Ahmadreza
    Jahromi, Sina Khajeh
    Rad, Melina Rouhi
    TRAUMA MONTHLY, 2013, 18 (02) : 67 - 70
  • [10] Medial Displacement Calcaneal Osteotomy: A Comparison of Screw Versus Locking Plate Fixation
    Sakena, Amol
    Patel, Rajan
    JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (06): : 1164 - 1168