Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study

被引:23
|
作者
Han, Hyun Ho [1 ]
Jun, Daiwon [2 ]
Moon, Suk-Ho [2 ]
Kang, In Sook [3 ]
Kim, Min Cheol [3 ]
机构
[1] Catholic Univ Korea, Incheon St Marys Hosp, Coll Med, Dept Plast & Reconstruct Surg, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Plast & Reconstruct Surg, Seoul, South Korea
[3] Catholic Univ Korea, St Vincents Hosp, Coll Med, Dept Plast & Reconstruct Surg, Seoul, South Korea
来源
SPRINGERPLUS | 2016年 / 5卷
关键词
Fibrin sealant; Suture; Thrombin; Fast clotting; Split-thickness skin graft; BURN WOUNDS; SEALANT; STAPLES; CLOSURE; TRIAL;
D O I
10.1186/s40064-016-3599-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Method: Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). Result: After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates (p < 0.05) except graft dislocation. Conclusion: When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate.
引用
收藏
页数:6
相关论文
共 3 条
  • [1] Fixation of Split-Thickness Skin Graft Using Fibrin Glue: A Comparison Study
    Elfanagely, Omar
    Diaz, Arturo Rios
    Messa, Charles A.
    Cunning, Jessica
    Broach, Robyn
    Fischer, John Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2020, 231 (04) : E185 - E185
  • [2] To Glue or Not to Glue? Analysis of Fibrin Glue for Split-thickness Skin Graft Fixation
    Mullens, Cody L.
    Messa, Charles A.
    Kozak, Geoffrey M.
    Rhemtulla, Irfan A.
    Fischer, Ohn P.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2019, 7 (05) : E2187
  • [3] Sticking to What Matters: A Matched Comparative Study of Fibrin Glue and Mechanical Fixation for Split-Thickness Skin Grafts in the Lower Extremity
    Othman, Sammy
    Messa, Charles A.
    Elfanagely, Omar
    Bormann, Bradford
    Mellia, Joseph A.
    Broach, Robyn B.
    Kovach, Stephen J.
    Fischer, John P.
    INTERNATIONAL JOURNAL OF LOWER EXTREMITY WOUNDS, 2024, 23 (02): : 231 - 237