Wind-induced motion control of 76-story benchmark building using the hybrid damper-TLCD system

被引:89
|
作者
Kim, H
Adeli, H
机构
[1] Ohio State Univ, Dept Civil & Environm Engn & Geodet Sci, Columbus, OH 43210 USA
[2] Res Inst Ind Sci & Technol, Hwasung 445810, Kyungkido, South Korea
关键词
motion; wind loads; bench marks; damping; vibration; hybrid methods;
D O I
10.1061/(ASCE)0733-9445(2005)131:12(1794)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The tuned liquid column damper (TLCD) has recently been advanced for vibration control of structures subjected to wind loading. The effectiveness of the semiactive TLCD system and the hybrid viscous fluid damper-TLCD control system recently proposed by the writers is investigated for control of wind-induced motion of high-rise buildings. Simulations are performed on a 76-story building benchmark control problem subjected to wind tunnel test data and stochastic wind loads. It is shown that the semiactive TLCD control system performs comparably to a sample active tuned mass damper (ATMD) system and thus is an attractive alternative to the ATMD system. More significantly, it is shown that the hybrid viscous fluid damper-TLCD system reduces the response of the building substantially more than the semiactive TLCD system at every natural frequency of the building. Furthermore, the hybrid damper-TLCD system is robust in terms of the stiffness modeling error for control of both displacement and acceleration responses. The simulation results show that the proposed hybrid viscous fluid damper-TLCD system can perform effectively under various wind loading conditions.
引用
下载
收藏
页码:1794 / 1802
页数:9
相关论文
共 50 条
  • [1] Bidirectional wind response control of 76-story benchmark building using active mass damper with a rotating actuator
    Zhang, Yu
    Li, Luyu
    Guo, Yuanbo
    Zhang, Xiaohua
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (10):
  • [2] Semiactive Wind Response Control of 76-story Benchmark Building with Smart Piezoelectric Friction Dampers
    Dong, Ping
    Fan, Jian
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 2196 - 2201
  • [3] Fuzzy control of 76-story wind-excited benchmark problem
    Zhang, Wei-Jing
    Ou, Jin-Ping
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 763 - 767
  • [4] Control Force Characteristics of Different Control Strategies for the Wind-Excited 76-Story Benchmark Building Structure
    Zhang, Chunwei
    ADVANCES IN STRUCTURAL ENGINEERING, 2014, 17 (04) : 543 - 559
  • [5] Vibration control of the wind-excited 76-story benchmark building by liquid column vibration absorbers
    Samali, B
    Mayol, E
    Kwok, KCS
    Mack, A
    Hitchcock, P
    JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (04) : 478 - 485
  • [6] Active control of cross wind response of 76-story tall building using a fuzzy controller
    Samali, B
    Al-Dawod, M
    Kwok, KCS
    Naghdy, F
    JOURNAL OF ENGINEERING MECHANICS, 2004, 130 (04) : 492 - 498
  • [7] Performance evaluation of tuned liquid column dampers for response control of a 76-story benchmark building
    Min, KW
    Kim, HS
    Lee, SH
    Kim, H
    Ahn, SK
    ENGINEERING STRUCTURES, 2005, 27 (07) : 1101 - 1112
  • [8] Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building
    Sameer J Suthar
    Radhey Shyam Jangid
    Journal of Vibration Engineering & Technologies, 2022, 10 : 2935 - 2945
  • [9] Optimal Design of Tuned Liquid Column Damper for Wind-induced Response Control of Benchmark Tall Building
    Suthar, Sameer J.
    Jangid, Radhey Shyam
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2022, 10 (08) : 2935 - 2945
  • [10] CONTROL OF WIND-INDUCED VIBRATIONS USING AN IMPACT MASS DAMPER
    OGAWA, K
    SAKAI, Y
    SAKAI, F
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 43 (1-3) : 1881 - 1882