An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe

被引:176
|
作者
Lopez, Carolina Mora [1 ]
Andrei, Alexandru [1 ]
Mitra, Srinjoy [1 ]
Welkenhuysen, Marleen [1 ]
Eberle, Wolfgang [1 ]
Bartic, Carmen [2 ]
Puers, Robert [3 ]
Yazicioglu, Refet Firat [1 ]
Gielen, Georges G. E. [3 ]
机构
[1] IMEC, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Dept Phys & Astron, B-3001 Louvain, Belgium
[3] Katholieke Univ Leuven, ESAT, Dept Elect Engn, B-3001 Louvain, Belgium
关键词
Active neural probe; biomedical sensor; brain-machine interface; CMOS; implantable biomedical device; microelectrodes; multi-electrode arrays; neural amplifier; neural interface; neural probe; neural recording; INTEGRATED-CIRCUIT; MU-W; MICROSYSTEM; RECORDINGS; POTENTIALS; INTERFACE; AMPLIFIER; SYSTEM; UNIT;
D O I
10.1109/JSSC.2013.2284347
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Neural probes have become the most important tool for enabling neuroscientists to place microelectrode sensors close to individual neurons and to monitor their activity in vivo. With such devices, it is possible to perform acute or chronic extracellular recordings of electrical activity from a single neuron or from groups of neurons. After the many developments in neural implants, it has become clear that large arrays of electrodes are desirable to further investigate the activity performed by complex neural networks. Therefore, in this paper, we propose a CMOS neural probe containing 455 active electrodes in the probe shank (100 mu m wide, 10 mm long, and 50 mu m thick) and 52 simultaneous readout channels in the probe body (2.9 x 3.3 mm(2)). In situ amplification under each electrode enables low-impedance interconnection lines, regardless of the electrode impedance, with a residual crosstalk of -44.8 dB. This design has been implemented in a 0.18-mu m standard CMOS technology, with additional CMOS-compatible post-processing performed at wafer level to define the electrodes and the probe outline. In this architecture, the analog front-end achieves an input-referred noise of 3.2 mu V and an NEF of 3.08. The power consumption of the core circuit is 949.8 mu W, while the total power consumption is 1.45 mW. The high-density active-electrode array in this neural probe allows for the massive recording of neural activity. In vivo measurements demonstrate successful simultaneous recordings from many individual cells.
引用
收藏
页码:248 / 261
页数:14
相关论文
共 18 条
  • [1] An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
    Lopez, Carolina Mora
    Andrei, Alexandru
    Mitra, Srinjoy
    Welkenhuysen, Marleen
    Eberle, Wolfgang
    Bartic, Carmen
    Puers, Robert
    Yazicioglu, Refet Firat
    Gielen, Georges
    2013 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE DIGEST OF TECHNICAL PAPERS (ISSCC), 2013, 56 : 288 - +
  • [2] SiNAPS: An implantable active pixel sensor CMOS-probe for simultaneous large-scale neural recordings
    Angotzi, Gian Nicola
    Boi, Fabio
    Lecomte, Aziliz
    Miele, Ermanno
    Malerba, Mario
    Zucca, Stefano
    Casile, Antonino
    Berdondini, Luca
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 355 - 364
  • [3] Implantable Wireless 64-channel System with Flexible ECoG Electrode and Optogenetics Probe
    Yoshimoto, Shusuke
    Araki, Teppei
    Uemura, Takafumi
    Nezu, Toshikazu
    Sekitani, Tsuyoshi
    Suzuki, Takafumi
    Yoshida, Fumiaki
    Hirata, Masayuki
    PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 476 - 479
  • [4] Noise performance design of CMOS preamplifier for the active semiconductor neural probe
    Kim, KH
    Kim, SJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (08) : 1097 - 1105
  • [5] Implantable probe with integrated reference electrode for in situ neural signal and calcium ion monitoring
    Xiao, Junyu
    Xu, Mengfei
    Wang, Longchun
    Yang, Bin
    Liu, Jingquan
    BIO-DESIGN AND MANUFACTURING, 2024, 7 (04) : 591 - 595
  • [6] Implantable probe with integrated reference electrode for in situ neural signal and calcium ion monitoring
    Junyu Xiao
    Mengfei Xu
    Longchun Wang
    Bin Yang
    Jingquan Liu
    Bio-Design and Manufacturing, 2024, 7 (04) : 591 - 595
  • [7] A 16-channel Si probe monolithically integrated with CMOS chips for neural recording
    Gou, Guang-Yang
    You, Changhua
    Yao, Pan
    Guo, Yu-Sen
    Liu, Tie-Zhu
    Song, Zi-Xuan
    Yin, Minghui
    Zhang, Xuan
    Liu, Chunxiu
    Zhou, Jun
    Sun, Xuan
    Zhuang, Chengyu
    Gu, Yuan-Dong
    Yao, Lei
    Xue, Ning
    Zhao, Ming
    SENSORS AND ACTUATORS REPORTS, 2024, 8
  • [8] A 966-Electrode Neural Probe with 384 Configurable Channels in 0.13μm SOI CMOS
    Lopez, Carolina Mora
    Mitra, Srinjoy
    Putzeys, Jan
    Raducanu, Bogdan
    Ballini, Marco
    Andrei, Alexandru
    Severi, Simone
    Welkenhuysen, Marleen
    Van Hoof, Chris
    Musa, Silke
    Yazicioglu, Refet Firat
    2016 IEEE INTERNATIONAL SOLID-STATE CIRCUITS CONFERENCE (ISSCC), 2016, 59 : 392 - U550
  • [9] Demonstration of Implantable Grid Electrode/3-Dimensional Probe Array for ECOG and Extracellular Neural Recording on Rat
    Chou, Lei-Chun
    Chang, Chih-Wei
    Chiou, Jin-Chern
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 85 - 85
  • [10] Active Neural Probes in CMOS Technology with Dense Electrode Arrangement for High-resolution Intracerebral Recording
    Paul, O.
    Galchev, T.
    Herbawi, A. S.
    Larramendy, F.
    Ruther, P.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1065 - S1065