Harmonic measurements, analysis, and power factor correction in a modern steel manufacturing facility

被引:50
|
作者
Andrews, D [1 ]
Bishop, MT [1 ]
Witte, JF [1 ]
机构
[1] COOPER POWER SYST,SYST ENGN GRP,FRANKSVILLE,WI 53126
关键词
D O I
10.1109/28.502174
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Maximizing electric power transfer directly affects the productivity of an electric are furnace operation, Are furnaces and rolling mill loads operate at power factors that result in penalty charges and lower bus voltages, In addition, the nonlinear characteristics of the furnace arcs and rolling mill drives generate significant harmonic currents that flow through the plant and utility power system, These harmonic currents cause system voltage distortion and power loss in the system, and can interact with power factor correction capacitor banks leading to equipment failures. This paper presents the analytical technique used to correct power factor in a modern steel manufacturing facility, The study included field measurements, harmonic analysis, and filter design work to reduce the amount of harmonic distortion in the plant, The modeling of are furnaces and rolling mills for a harmonic analysis study is also discussed, The solutions recommended in this paper to increase power factor and reduce harmonics can be applied to other steel manufacturing facilities to improve power quality and therefore plant productivity.
引用
收藏
页码:617 / 624
页数:8
相关论文
共 50 条
  • [1] Harmonic Measurements and Analysis in a Modern Steel Manufacturing Facility
    Bao, Minghui
    Xia, Jun
    Yin, Xiaogen
    Dong, Manling
    He, Hengxin
    He, Junjia
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [2] Estimation and Analysis of Harmonics and Power Factor Correction in a Modern Steel Manufacturing Facility
    Khatua P.
    Murugesan S.
    Murali V.
    Journal of The Institution of Engineers (India): Series B, 2019, 100 (05) : 425 - 434
  • [3] Harmonic measurements and power factor correction in a factory
    Türkay, Belgin
    Modelling, Measurement and Control A, 2002, 75 (1-2): : 47 - 55
  • [4] Power Factor Correction in Harmonic Environment
    Yang, Chao
    MATERIAL AND MANUFACTURING TECHNOLOGY II, PTS 1 AND 2, 2012, 341-342 : 821 - 824
  • [5] Manufacturing and cost analysis of power-factor-correction circuits
    Sharifipour, B
    Huang, JS
    Liao, P
    Huber, L
    Jovanovic, MM
    APEC '98 - THIRTEENTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 1998, : 490 - 494
  • [6] Modern power factor correction technology
    Duerden, Neil
    Engineering Technology, 2000, 3 (09):
  • [7] Power factor correction and harmonic mitigation in industry
    Ortega, JMM
    Payán, MB
    Mitchell, CI
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3127 - 3134
  • [8] Dynamic harmonic mitigation and power factor correction
    Chavez, Cesar
    Houdek, John. A.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION, VOLS 1 AND 2, 2007, : 606 - +
  • [9] Harmonic resonance analysis for PEP-II power factor correction upgrades
    Stanford Univ, Stanford, United States
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 3 : 3746 - 3748
  • [10] Stability Analysis of Active Harmonic Filter in presence of Power Factor Correction Capacitors
    Vaidya, Tushar G.
    Chatterjee, Kishore
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1300 - 1305