Experimental study on pull-out response of geogrid embedded in sand

被引:30
|
作者
Kayadelen, Cafer [1 ]
Onal, Taha Okkes [1 ]
Altay, Gokhan [1 ]
机构
[1] Osmaniye Korkut Ata Univ, Dept Civil Engn, Merkez Osmaniye, Turkey
关键词
Geogrid; Sand; Pull-out resistance; Reinforced soil; RESISTANCE; ANCHOR;
D O I
10.1016/j.measurement.2017.12.024
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Geosynthetics have been widely employed to reinforce the soils over the last two decades. Pullout resistance and interface friction resistance of the geogrids are crucial design parameters for some geotechnical applications. In this study, the effects of pull-out resistance of geogrid material embedded in sand soil was examined by using simple shear test set-up with a little modification. Thus, a series of experiments carried on sand soil with different relative densities and gradations. In the tests, poor graded sand was reinforced with geogrid. The reinforcement material has 0.85 mm thickness and 1 cm grid aperture. It can be inferenced from experiments that behavior of pull-out resistance had resemblance to classical load-displacement behavior of soil. Classically when displacement increases pull-out resistance increases until a certain displacement but after a certain pull-out resistance when displacement increases pull-out resistance decreases. The tests showed that, the increase in relative density leaded to increase in pull-out load. Due to the interlocking of soil grains with geogrid gaps, interface friction between soil and geogrid was also observed greater than internal friction of soil.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 50 条
  • [1] Pull-out response of a geogrid buried in recycled sands
    Oliveira, Priscila F. S.
    Santos, Eder C. G.
    Palmeira, Ennio M.
    SOILS AND ROCKS, 2024, 47 (04):
  • [2] Researches on interacton mechanism between geogrid and sand by pull-out tests
    Xu Chao
    Liao Xing-yue
    ROCK AND SOIL MECHANICS, 2011, 32 (02) : 423 - 428
  • [3] Geogrid pull-out test in clay
    Costalonga, M.A.R.
    Proceedings of the International Conference on Geotextiles, Geomembranes and Related Products, 1990,
  • [4] PULL-OUT RESISTANCE OF GEOGRID REINFORCEMENTS
    FARRAG, K
    ACAR, YB
    JURAN, I
    GEOTEXTILES AND GEOMEMBRANES, 1993, 12 (02) : 133 - 159
  • [5] Experimental study on the interaction mechanism between geogrid and expansive rock by pull-out test
    Ding, J. H.
    Tong, J.
    Bao, C. G.
    GEOSYNTHETICS IN CIVIL AND ENVIRONMENTAL ENGINEERING, 2008, : 763 - 768
  • [6] A laboratory study on pull-out resistance of geogrid in clay soil
    Altay, Gokhan
    Kayadelen, Cafer
    Taskiran, Taha
    Kaya, Yunus Ziya
    MEASUREMENT, 2019, 139 : 301 - 307
  • [7] The seepage study of transient caisson pull-out in sand
    Moghaddam, Firoozeh
    Imam, Reza
    OCEAN ENGINEERING, 2022, 258
  • [8] An Experimental Investigation into the Pull-out Capacity of Suction Caissons in Sand
    Kakasoltani, Siamak
    Zeinoddini, Mostafa
    Abdi, Mahmood R.
    Arabzadeh, Hamid
    OMAE2011: PROCEEDINGS OF THE ASME 30TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, VOL 1: OFFSHORE TECHNOLOGY: POLAR AND ARCTIC SCIENCES AND TECHNOLOGY, 2011, : 21 - 27
  • [9] Pull-out test of uniaxial geogrid with strengthening ribs
    Cai Chun
    Zhang Meng-xi
    Zhao Gang-fei
    Li Jie
    Wu Li-wei
    ROCK AND SOIL MECHANICS, 2012, 33 (01) : 53 - +
  • [10] Pull-out tests of biaxial geogrid with strengthening nodes
    Li, Lei
    Zhang, Meng-Xi
    Zhou, Xiao-Feng
    Zhu, Hong
    Shuili Xuebao/Journal of Hydraulic Engineering, 2012, 43 (12): : 1494 - 1499