共 50 条
Systematic Review and Meta-Analysis of Detecting Galactomannan in Bronchoalveolar Lavage Fluid for Diagnosing Invasive Aspergillosis
被引:143
|作者:
Zou, Mingxiang
[1
]
Tang, Lanhua
[2
]
Zhao, Shushan
[2
]
Zhao, Zijin
[2
]
Chen, Luyao
[2
]
Chen, Peng
[3
]
Huang, Zebing
[4
]
Li, Jun
[1
]
Chen, Lizhang
[5
]
Fan, Xuegong
[4
]
机构:
[1] Cent S Univ, Xiangya Hosp, Dept Clin Lab, Changsha, Hunan, Peoples R China
[2] Cent S Univ, Xiangya Hosp, Year Program 8, Changsha, Hunan, Peoples R China
[3] Cent S Univ, Xiangya Sch Med, Changsha, Hunan, Peoples R China
[4] Cent S Univ, Xiangya Hosp, Dept Infect Dis, Changsha, Hunan, Peoples R China
[5] Cent S Univ, Sch Publ Hlth, Changsha, Hunan, Peoples R China
来源:
关键词:
REAL-TIME PCR;
LINKED-IMMUNOSORBENT-ASSAY;
POLYMERASE-CHAIN-REACTION;
PULMONARY ASPERGILLOSIS;
ENZYME-IMMUNOASSAY;
ANTIGEN-DETECTION;
HEMATOLOGY PATIENTS;
FUNGAL-INFECTIONS;
SERUM;
FUMIGATUS;
D O I:
10.1371/journal.pone.0043347
中图分类号:
O [数理科学和化学];
P [天文学、地球科学];
Q [生物科学];
N [自然科学总论];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
Background: Bronchoalveolar lavage (BAL) galactomannan (GM) assay has been used for diagnosing invasive aspergillosis (IA). We aimed to derive a definitive estimate of the overall accuracy of BAL-GM for diagnosing IA. Methods and Results: We undertook a systematic review of thirty diagnostic studies that evaluated the BAL-GM assay for diagnosing IA. PubMed and CBM (China Biological Medicine Database) databasees were searched for relevant studies published in all languages up until Feb 2012. The pooled diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) were constructed for each cutoff value. Additionally, pooled sensitivity (SEN), specificity (SPE), and positive and negative likelihood ratios (PLR and NLR, respectively) were calculated for summarizing overall test performance. Thirty studies were included in this meta-analysis. The summary estimates of pooled DOR, SEN, SPE, PLR, and NLR of the BAL-GM assay (cutoff value 0.5) for proven or probable IA were 52.7 (95% confidence interval (CI) 31.8-87.3), 0.87 (95% CI 0.79-0.92), 0.89 (95% CI 0.85-0.92), 8.0 (95% CI 5.7-11.1) and 0.15 (95% CI 0.10-0.23) respectively. The SROC was 0.94 (95% CI 0.92-0.96). Compared with cutoff value of 0.5, it has higher DOR, SPE and PLR, and similar SEN and NLR with cutoff value of 1.0, which indicated the optimal cutoff value might be 1.0. Compared with BAL-GM, serum GM has a lower SEN and higher SPE, while PCR displays a lower SEN and a similar SPE. Conclusion: With the optimal cutoff value of 1.0, the BAL-GM assay has higher SEN compared to PCR and serum GM test. It is a useful adjunct in the diagnosis of proven and probable IA.
引用
收藏
页数:12
相关论文