Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator

被引:62
|
作者
Liu, X. H. [1 ]
Jiang, Y. [1 ]
Yi, X. Q. [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Regenerator; Heat and mass transfer; Flow pattern; MASS-TRANSFER; AIR DEHUMIDIFICATION; COOLING SYSTEMS; HEAT; LITHIUM;
D O I
10.1016/j.renene.2008.03.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The regenerator is one of the key components in liquid desiccant air-conditioning systems, in which desiccant is concentrated and can be reused in the system. The regeneration heat is supplied into the regenerator by either hot air or hot desiccant. The heat and mass transfer performances of these two regeneration modes are analyzed and compared in detail. In the hot air driven regenerator, the parallel-flow regenerator has the best mass transfer performance and the counter-flow performs poorest under the same conditions, because the heat transfer process is the governing process and the mass transfer performance depends on the promotion of the heat transfer to the mass transfer process. In the hot desiccant driven regenerator, counter-flow configuration has the best mass transfer performance and parallel-flow is the poorest at the same conditions, since mass transfer is the governing process. Regeneration heat should be chosen to heat the desiccant instead of the air in the packed bed regenerator, since the hot desiccant driven regenerator has apparent better mass transfer performance. The proposed regeneration mode and flow pattern will be helpful in the design and optimization of the regenerators. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:209 / 216
页数:8
相关论文
共 50 条
  • [1] Quick performance prediction of liquid desiccant regeneration in a packed bed
    Gandhidasan, P
    SOLAR ENERGY, 2005, 79 (01) : 47 - 55
  • [2] Performance study on a structured packed liquid desiccant regenerator
    Elsarrag, Esam
    SOLAR ENERGY, 2006, 80 (12) : 1624 - 1631
  • [3] Performance investigation on the liquid desiccant regeneration using rotating packed bed
    Gu, Yangyang
    Zhang, Xiaosong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 109 (109) : 45 - 54
  • [4] Simplified model for packed-bed tower regenerator in a liquid desiccant system
    Kim, Min-Hwi
    Park, Joon-Young
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2015, 89 : 717 - 726
  • [5] Study on the performance of celdek packed counter flow liquid desiccant regenerator
    Kumar, Rakesh
    Asati, Arun Kumar
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (09) : 4489 - 4498
  • [6] Study on the performance of celdek packed counter flow liquid desiccant regenerator
    Rakesh Kumar
    Arun Kumar Asati
    Journal of Mechanical Science and Technology, 2017, 31 : 4489 - 4498
  • [7] Effectiveness of heat and mass transfer processes in a packed bed liquid desiccant dehumidifier/regenerator
    Martin, V
    Goswami, DY
    HVAC&R RESEARCH, 2000, 6 (01): : 21 - 39
  • [8] Performance study on the dehumidifier of a packed bed liquid desiccant system
    Salarian, H.
    Ghorbani, B.
    Amidpour, Majid
    Salehi, G.
    SCIENTIA IRANICA, 2014, 21 (01) : 222 - 228
  • [9] Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant
    Liu, X. H.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1357 - 1366
  • [10] Numerical and experimental study on the regeneration performance of a liquid desiccant system coupled with rotating packed bed and vacuum
    Li, Hongxuan
    Zou, Tonghua
    Han, Xiaowan
    Dai, Baomin
    Liu, Jia
    APPLIED ENERGY, 2023, 336