Simultaneous label-free and pretreatment-free detection of heavy metal ions in complex samples using electrodes decorated with vertically-ordered silica nanochannels

被引:95
|
作者
Cheng, Bowen [1 ]
Zhou, Lin [1 ]
Lu, Lili [1 ]
Liu, Jiyang [1 ]
Dong, Xiaoping [1 ]
Xi, Fengna [1 ]
Chen, Peng [2 ]
机构
[1] Zhejiang Sci Tech Univ, Dept Chem, Xiasha Higher Educ Zone, 5 Second Ave, Hangzhou 310018, Zhejiang, Peoples R China
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, 70 Nanyang Dr, Singapore 637457, Singapore
基金
中国国家自然科学基金;
关键词
Electrochemical sensing; Vertically-ordered silica nanochannels; Detection of heavy metal ions; SIMULTANEOUS ELECTROCHEMICAL DETECTION; FUNCTIONALIZED MESOPOROUS SILICA; SELECTIVE DETECTION; ORGANOSILICA FILMS; WATER SAMPLES; LEAD; PB2+; MESOCHANNELS; FABRICATION; MEMBRANES;
D O I
10.1016/j.snb.2017.12.083
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, indium tin oxide coated glass (ITO) decorated with vertically-ordered mesoporous silica film (VMSF/ITO) is synthesized and applied as electrochemical sensor for simultaneous label-free and pretreatment-free detection of Pb2+, Cu2+, and Cd2+ in human serum and soil leaching solution. Using differential pulse voltammetry (DPV), the electrochemical detection consists of electro-deposition of metal species and subsequent anodic stripping in the silica nanochannels. Because of the electrostatic enrichment and nano-confinement effects, VMSF/ITO is able to simultaneously detect Pb2+, Cu2+, and Cd2+ in a mixture with low detection limits (2.6 nM, 32 nM and 230 nM, respectively). Moreover, VMSF confer the electrode with excellent anti-fouling and anti-interference property through steric exclusion and electrostatic repulsion. Direct analysis of complex biological (human serum) and environmental (soil leaching solution) samples could be finished within 10 min without the usual need of tedious pretreatment. Furthermore, the VMSF/ITO sensor can be reused for several times without performance degradation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:364 / 371
页数:8
相关论文
共 11 条
  • [1] Colorimetric Detection of Heavy Metal Ions Using Label-Free Gold Nanoparticles and Alkanethiols
    Hung, Yu-Lun
    Hsiung, Tung-Ming
    Chen, Yi-You
    Huang, Yu-Fen
    Huang, Chih-Ching
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (39): : 16329 - 16334
  • [2] Label-Free Colorimetric Detection of Cadmium Ions in Rice Samples Using Gold Nanoparticles
    Guo, Yongming
    Zhang, Yi
    Shao, Huawu
    Wang, Zhuo
    Wang, Xuefei
    Jiang, Xingyu
    ANALYTICAL CHEMISTRY, 2014, 86 (17) : 8530 - 8534
  • [3] Pretreatment-free selective and reproducible SERS-based detection of heavy metal ions on DTPA functionalized plasmonic platform
    Guselnikova, O.
    Postnikov, P.
    Erzina, M.
    Kalachyova, Y.
    Svorcik, V.
    Lyutakov, O.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 : 830 - 838
  • [4] Field and Pretreatment-Free Detection of Heavy-Metal Ions in Organic Polluted Water through an Alkyne-Coded SERS Test Kit
    Zeng, Yi
    Ren, Jiaqiang
    Shen, Aiguo
    Hu, Jiming
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (41) : 27772 - 27778
  • [5] Heavy metal-free electrochemical detection of pyrophosphate ions by Nafion/carbon dots decorated screen printed carbon electrodes
    Chang, Che-Wei
    Liao, Wei-Ssu
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2023, 70 (06) : 1409 - 1416
  • [6] Simultaneous detection of multiple tumor markers by label-free electrochemical immunoassay using chip-like glass carbon electrodes
    Wang, Huiqiang
    Ma, Zhanfang
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 256 : 402 - 407
  • [7] A label-free and homogenous electrochemical assay for matrix metalloproteinase 2 activity monitoring in complex samples based on electrodes modified with orderly distributed mesoporous silica films
    Duan, Shuangdi
    Peng, Jiaxin
    Cheng, Hong
    Li, Wei
    Jia, Ruichen
    Liu, Jinquan
    He, Xiaoxiao
    Wang, Kemin
    TALANTA, 2021, 231 (231)
  • [8] A specific short peptide-assisted enhanced chemiluminescence resonance energy transfer (CRET) for label-free and ratiometric detection of copper ions in complex samples
    Xiong, Yamin
    Zhou, Lihong
    Peng, Xiaoxia
    Li, Huiling
    Wang, Hui
    He, Leiliang
    Huang, Peili
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 320
  • [9] Platform- and label-free detection of lead ions in environmental and laboratory samples using G-quadraplex probes by circular dichroism spectroscopy
    Kim, Raeyeong
    Youn, Young-Sang
    Kang, Misook
    Kim, Eunjoo
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] Platform- and label-free detection of lead ions in environmental and laboratory samples using G-quadraplex probes by circular dichroism spectroscopy
    Raeyeong Kim
    Young-Sang Youn
    Misook Kang
    Eunjoo Kim
    Scientific Reports, 10