THE CORRELATION ANALYSIS OF THE SHAPE PARAMETERS FOR ENDOTHELIAL IMAGE CHARACTERISATION

被引:9
|
作者
Nurzynska, Karolina [1 ]
Piorkowski, Adam [2 ]
机构
[1] Silesian Tech Univ, Fac Automat Control Elect & Comp Sci, Inst Informat, Ul Akad 16, PL-44100 Gliwice, Poland
[2] AGH Univ Sci & Technol, Dept Geoinformat & Appl Comp Sci, Krakow, Poland
来源
IMAGE ANALYSIS & STEREOLOGY | 2016年 / 35卷 / 03期
关键词
correlation analysis; endothelial images; shape parameters; CORNEAL ENDOTHELIUM; FRACTAL DIMENSION; CELL-DENSITY; SEGMENTATION; NUCLEI;
D O I
10.5566/ias.1554
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Microscopic images of corneal endothelium cells are investigated to deliver information about their medical state. Although this could be achieved automatically, this examination is manual and very time consuming. Two medical parameters for endothelial layer quality description have been introduced and more are planned. Yet, since they will exploit image processing, a thoughtful overview of applicable existing shape parameters is necessary. This work investigates the possibility of exploiting well-known image processing techniques for describing the endothelial layer by calculating information about shape features using spatial moments or topological attributes. The comparison concentrates on finding which shape measures could be combined to improve descriptions, and which cannot due to their high correlation and the fact that they do not contain any new information. The performed experiments revealed a set of 17 non-correlated features and four groups of shape parameters that show some correlation, but one representative can always be selected. Moreover, the investigation proved some correlation between the metrics used in medicine and considered shape features.
引用
收藏
页码:149 / 158
页数:10
相关论文
共 50 条
  • [1] Characterisation of the shape of aggregates using image analysis
    Subramaniam, Daniel Niruban
    Dassanayake, Dassanayake Hitihamilage Hiruni Pubudika
    Ahilash, Navakulan
    Wijekoon, Sathushka Heshan Bandara
    Sathiparan, Navaratnarajah
    INTERNATIONAL JOURNAL OF PAVEMENT ENGINEERING, 2024, 25 (01)
  • [2] Crystal Shape Characterisation of Dry Samples using Microscopic and Dynamic Image Analysis
    Patchigolla, Kumar
    Wilkinson, Derek
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2009, 26 (04) : 171 - 178
  • [3] Image analysis framework with focus evaluation for in situ characterisation of particle size and shape attributes
    Cardona, Javier
    Ferreira, Carla
    McGinty, John
    Hamilton, Andrew
    Agimelen, Okpeafoh S.
    Cleary, Alison
    Atkinson, Robert
    Michie, Craig
    Marshall, Stephen
    Chen, Yi-Chieh
    Sefcik, Jan
    Andonovic, Ivan
    Tachtatzis, Christos
    CHEMICAL ENGINEERING SCIENCE, 2018, 191 : 208 - 231
  • [4] Correlation Analysis between Pulmonary Function Test Parameters and CT Image Parameters of Emphysema
    Liu, Cheng-Pei
    Li, Chia-Chen
    Yu, Chong-Jen
    Chang, Yeun-Chung
    Wang, Cheng-Yi
    Yu, Wen-Kuang
    Chen, Chung-Ming
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [5] Calibration of concrete parameters based on digital image correlation and inverse analysis
    Gajewski, T.
    Garbowski, T.
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2014, 14 (01) : 170 - 180
  • [6] Agata characterisation and pulse shape analysis
    A. J. Boston
    F. C. L. Crespi
    G. Duchêne
    P. Désesquelles
    J. Gerl
    F. Holloway
    D. S. Judson
    A. Korichi
    L. Harkness-Brennan
    J. Ljungvall
    B. Quintana-Arnés
    P. Reiter
    O. Stezowski
    The European Physical Journal A, 59
  • [7] Agata characterisation and pulse shape analysis
    Boston, A. J.
    Crespi, F. C. L.
    Duchene, G.
    Desesquelles, P.
    Gerl, J.
    Holloway, F.
    Judson, D. S.
    Korichi, A.
    Harkness-Brennan, L.
    Ljungvall, J.
    Quintana-Arnes, B.
    Reiter, P.
    Stezowski, O.
    EUROPEAN PHYSICAL JOURNAL A, 2023, 59 (09):
  • [8] Use of image analysis for sludge characterisation:: studying the relation between floc shape and sludge settleability
    Jenne, R.
    Banadda, E. N.
    Gins, G.
    Deurinck, J.
    Smets, I. Y.
    Geeraerd, A. H.
    Van Impe, J. F.
    WATER SCIENCE AND TECHNOLOGY, 2006, 54 (01) : 167 - 174
  • [9] Influence of Shape of Region of Interest on the Architectural Parameters in Micro CT Image Analysis
    Yan, Yabo
    Wang, Jun
    Qi, Wei
    Zhang, Yang
    Lei, Wei
    MECHANICAL PROPERTIES OF MATERIALS AND INFORMATION TECHNOLOGY, 2012, 340 : 241 - 247
  • [10] Correlation of endothelial vimentin content with hemodynamic parameters
    H.-J. Schnittler
    T. Schmandra
    Detlev Drenckhahn
    Histochemistry and Cell Biology, 1998, 110 : 161 - 167