Impact of plaque accumulation on the osseointegration of titanium-zirconium alloy and titanium implants. A histological and immunohistochemical analysis

被引:7
|
作者
Schwarz, Frank [1 ]
Mihatovic, Ilja [1 ]
Golubovic, Vladimir [1 ]
Bradu, Sebastian [1 ]
Sager, Martin [2 ]
Becker, Juergen [1 ]
机构
[1] Univ Dusseldorf, Dept Oral Surg, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Anim Res Inst, D-40225 Dusseldorf, Germany
关键词
experimental mucositis; histomorphometry; surface hydrophilicity; titanium-zirconium alloy; BONE APPOSITION; SURFACES; INTEGRATION;
D O I
10.1111/clr.12452
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo evaluate the impact of plaque accumulation on osseointegration at surface enhanced modified hydrophilic titanium-zirconium (TiZr) alloy and titanium (Ti) implants. Materials and methodsTiZr and Ti implants with a sand-blasted, acid etched, and chemically modified endosseous and a machined (M) transmucosal portion were bilaterally (i.e., one implant type on each side) inserted in the maxilla of six foxhounds. In a split-mouth design, experimental mucositis was induced at one randomly assigned side (NPC), while the contralateral side received mechanical plaque removal three times per week (PC). After 16weeks, tissue biopsies were processed for histological (primary outcome: bone-to-implant contact [BIC]) and immunohistochemical (CD68) analysis. ResultsMean BIC values varied between 81.96% (TiZrM) and 88.72% (TiM) in the NPC group, and between 87.88% (TiM) and 92.69% (TiZrM) in the PC group. Even though BIC values tended to be lower within the endosseous coronal compartment at NPC sites, within group (NPC vs. PC) comparisons failed to reach statistical significance at both types of implants. These non-BIC areas were not associated with any CD68 positive cells. ConclusionsOsseointegration of both TiZrM and TiM implants was not influenced by plaque accumulation in this experimental model.
引用
收藏
页码:1281 / 1287
页数:7
相关论文
共 50 条
  • [1] The osseointegration behavior of titanium-zirconium implants in ovariectomized rabbits
    Wen, Bo
    Zhu, Feng
    Li, Zhen
    Zhang, Peng
    Lin, Xingnan
    Dard, Michel
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (07) : 819 - 825
  • [2] Comparison of the Use of Titanium-Zirconium Alloy and Titanium Alloy in Dental Implants: A Systematic Review and Meta-Analysis
    Cruz, Ronaldo Silva
    Araujo Lemos, Cleidiel Aparecido
    Fernandes Oliveira, Hiskell Francine
    de Souza Batista, Victor Eduardo
    Pellizzer, Eduardo Piza
    Verri, Fellippo Ramos
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (04) : 305 - 312
  • [3] Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study
    Smeets, Ralf
    Schoellchen, Maximilian
    Gauer, Tobias
    Aarabi, Ghazal
    Assaf, Alexandre T.
    Rendenbach, Carsten
    Beck-Broichsitter, Benedicta
    Semmusch, Jan
    Sedlacik, Jan
    Heiland, Max
    Fiehler, Jens
    Siemonsen, Susanne
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (02)
  • [4] Strength of titanium-zirconium alloy implants with a conical connection after implantoplasty
    Shah, Sweety D.
    Zheng, Fengyuan
    Seghi, Robert R.
    Lee, Damian J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (03): : 593 - 599
  • [5] BONE APPOSITION TO A TITANIUM-ZIRCONIUM ALLOY IMPLANT, AS COMPARED TO TWO OTHER TITANIUM-CONTAINING IMPLANTS
    Saulacic, N.
    Bosshardt, D. D.
    Bornstein, M. M.
    Berner, S.
    Buser, D.
    EUROPEAN CELLS & MATERIALS, 2012, 23 : 273 - 288
  • [6] The effect of titanium aluminium nitride on the osseointegration of metallic implants.
    Freeman, CO
    Brook, IM
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1064 - 1064
  • [7] Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants
    Hanes, Brenda
    Feitosa, Sabrina
    Phasuk, Kamolphob
    Levon, John A.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 441 - 446
  • [8] Hydrogen content in titanium and a titanium-zirconium alloy after acid etching
    Frank, Matthias J.
    Walter, Martin S.
    Lyngstadaas, S. Petter
    Wintermantel, Erich
    Haugen, Havard J.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (03): : 1282 - 1288
  • [9] Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants
    Akca, Kivanc
    Eser, Atilim
    Cavusoglu, Yeliz
    Sagirkaya, Elcin
    Cehreli, Murat Cavit
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (05) : 453 - 462
  • [10] STUDY OF THE TITANIUM-ZIRCONIUM SILICIURES IN THE TI 685 ALLOY
    BARBIER, F
    SERVANT, MC
    QUESNE, C
    LACOMBE, MP
    JOURNAL DE MICROSCOPIE ET DE SPECTROSCOPIE ELECTRONIQUES, 1981, 6 (03): : 299 - &