Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference

被引:120
|
作者
Osborn, DA
Evans, N
Kluckow, M
机构
[1] Univ Sydney, Royal Prince Alfred Hosp, Sydney, NSW 2006, Australia
[2] Univ Sydney, Royal N Shore Hosp, Sydney, NSW 2006, Australia
关键词
D O I
10.1136/adc.2002.023796
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To determine the accuracy of blood pressure (BP), capillary refill time (CRT), and central-peripheral temperature difference (CPTd) for detecting low upper body blood flow in the first day after birth. Methods: A prospective, two centre cohort study of 128 infants born at < 30 weeks gestation. Invasive BP (n = 108), CRT (n = 128), and CPTd (n = 46) were performed immediately before echocardiographic measurement of superior vena cava (SVC) flow at three, 5-10, and 24 hours after birth. Results: Forty four (34%) infants had low SVC flow (< 41 ml/kg/min) in the first day, 13/122 (11%) at three hours, 39/126 (31%) at 5-10 hours, and 4/119 (3%) at 24 hours. CPTd did not detect infants with low flows. Combining all observations in the first 24 hours, CRT greater than or equal to 3 seconds had 55% sensitivity and 81% specificity, mean BP < 30 mm Hg had 59% sensitivity and 77% specificity, and systolic BP < 40 mm Hg had 76% sensitivity and 68% specificity for detecting low SVC flow. Combining a mean BP < 30 mm Hg and/or central CRT >= 3 seconds increases the sensitivity to 78%. Conclusions: Low upper body blood flow is common in the first day after birth and strongly associated with peri/intraventricular haemorrhage. BP and CRT are imperfect bedside tests for detecting low blood flow in the first day after birth.
引用
收藏
页码:168 / 173
页数:6
相关论文
共 8 条
  • [1] Central-peripheral temperature difference, blood pressure, and arginine vasopressin in preterm neonates undergoing volume expansion
    Lambert, HJ
    Baylis, PH
    Coulthard, MG
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1998, 78 (01): : F43 - F45
  • [2] Metabolic acidosis, core-peripheral temperature difference and blood pressure response to albumin infusion in hypotensive, very premature infants
    Dimitriou, G
    Greenough, A
    Mantagos, J
    Skinner, S
    [J]. JOURNAL OF PERINATAL MEDICINE, 2001, 29 (05) : 442 - 445
  • [3] Pilot study of Milrinone for prevention of low blood flow to brain and upper body in very preterm infants
    Paradisis, M
    Evans, N
    Osborn, D
    Kluckow, M
    [J]. PEDIATRIC RESEARCH, 2003, 53 (04) : 418A - 418A
  • [4] Relationship between blood pressure, cerebral electrical activity, cerebral fractional oxygen extraction, and peripheral blood flow in very low birth weight newborn infants
    Victor, S
    Marson, AG
    Appleton, RE
    Beirne, M
    Weindling, AM
    [J]. PEDIATRIC RESEARCH, 2006, 59 (02) : 314 - 319
  • [5] Relationship Between Blood Pressure, Cerebral Electrical Activity, Cerebral Fractional Oxygen Extraction, and Peripheral Blood Flow in Very Low Birth Weight Newborn Infants
    Suresh Victor
    Anthony G Marson
    Richard E Appleton
    Margaret Beirne
    A Michael Weindling
    [J]. Pediatric Research, 2006, 59 : 314 - 319
  • [6] Association of core body temperature and peripheral blood flow of the hands with pain intensity, pressure pain hypersensitivity, central sensitization, and fibromyalgia symptoms
    Casas-Barragan, Antonio
    Molina, Francisco
    Tapia-Haro, Rosa Maria
    Garcia-Rios, Maria Carmen
    Correa-Rodriguez, Maria
    Aguilar-Ferrandiz, Maria Encarnacion
    [J]. THERAPEUTIC ADVANCES IN CHRONIC DISEASE, 2021, 12
  • [7] MONITORING OF ARTERIO-VENOUS FISTULA MATURATION USING CENTRAL-VENOUS OXYGEN SATURATION AND ESTIMATED UPPER-BODY BLOOD FLOW: IMPACT ON CATHETER RESIDENCE TIME
    Merlo, Laura Rosales
    Zhang, Hanjie
    Ye, Xiaoling
    Chan, Brenda
    Mateo, Marilou
    Jhonson, Seth
    Kotanko, Peter
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2022, 37 : I566 - I567
  • [8] Robust, Beat-to-Beat Estimation of the True Pulse Transit Time from Central and Peripheral Blood Pressure or Flow Waveforms Using an Arterial Tube-Load Model
    Zhang, Guanqun
    Gao, Mingwu
    Mukkamala, Ramakrishna
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4291 - 4294