Design and analysis of fractional order seismic transducer for displacement and acceleration measurements

被引:7
|
作者
Veeraian, Parthasarathi [1 ]
Gandhi, Uma [1 ]
Mangalanathan, Umapathy [1 ]
机构
[1] Natl Inst Technol, Dept Instrumentat & Control Engn, Tiruchirappalli, Tamil Nadu, India
关键词
Acceleration measurement; Displacement measurement; Dynamic range; Fractional order model; Seismic transducer; CONSTANT PHASE ELEMENT; ACCELEROMETER; DIFFERENTIATOR; IDENTIFICATION; CALCULUS; SYSTEM;
D O I
10.1016/j.jsv.2018.01.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Seismic transducers are widely used for measurement of displacement, velocity, and acceleration. This paper presents the design of seismic transducer in the fractional domain for the measurement of displacement and acceleration. The fractional order transfer function for seismic displacement and acceleration transducer are derived using Grunwald-Letnikov derivative. Frequency response analysis of fractional order seismic displacement transducer (FOSDT) and fractional order seismic acceleration transducer (FOSAT) are carried out for different damping ratio with the different fractional order, and the maximum dynamic measurement range is identified. The results demonstrate that fractional order seismic transducer has increased dynamic measurement range and less phase distortion as compared to the conventional seismic transducer even with a lower damping ratio. Time response of FOSDT and FOSAT are derived analytically in terms of Mittag-Leffler function, the effect of fractional behavior in the time domain is evaluated from the impulse and step response. The fractional order system is found to have significantly reduced overshoot as compared to the conventional transducer. The fractional order seismic transducer design proposed in this paper is illustrated with a design example for FOSDT and FOSAT. Finally, an electrical equivalent of FOSDT and FOSAT is considered, and its frequency response is found to be in close agreement with the proposed fractional order seismic transducer. (c) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:123 / 139
页数:17
相关论文
共 50 条
  • [1] OPTICAL TRANSDUCER FOR DISPLACEMENT MEASUREMENTS
    LEARY, BG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1958, 29 (03): : 246 - 247
  • [2] Design charts for yield acceleration and seismic displacement of retaining walls with surcharge through limit analysis
    Aminpoor, Mohamad Mahdi
    Ghanbari, Ali
    STRUCTURAL ENGINEERING AND MECHANICS, 2014, 52 (06) : 1225 - 1256
  • [3] Acceleration Displacement Response Spectra for Design of Seismic Isolation Systems in Turkey
    Yolcu, Aslihan
    Tanircan, Gulum
    Tuzun, Cuneyt
    TEKNIK DERGI, 2021, 32 (02): : 10629 - 10643
  • [4] THE ACCELERATION TRANSDUCER - AN ASSESSMENT OF ITS PRECISION IN COMPARISON WITH A FORCE DISPLACEMENT TRANSDUCER
    MAY, O
    NIELSEN, HK
    WERNER, MU
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1988, 32 (03) : 239 - 243
  • [5] What is the best displacement transducer for a seismic sensor?
    Novotny, Peter
    Aimard, Benjamin
    Balik, Gael
    Brunetti, Laurent
    Caron, Bernard
    Gaddi, Andrea
    2017 4TH IEEE INTERNATIONAL SYMPOSIUM ON INERTIAL SENSORS AND SYSTEMS (INERTIAL), 2017, : 121 - 124
  • [6] Seismic-induced permanent displacement estimation combining acceleration and computer vision measurements
    Choi, Jaemook
    Chung, Junyeon
    Kim, Kiyoung
    Sohn, Hoon
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2023, 200
  • [7] Realization of Fractional Order Inductive Transducer
    Sarathi, V. Partha
    Uma, G.
    Umapathy, M.
    IEEE SENSORS JOURNAL, 2018, 18 (21) : 8803 - 8811
  • [8] Analysis of a Fractional-Order Couple Model with Acceleration in Feelings
    Koca, Ilknur
    Ozalp, Nuri
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [9] DESIGN AND CONSTRUCTION OF A LINEAR DISPLACEMENT TRANSDUCER
    FREMIOT, C
    DELAPIER.G
    MICHAUD, JF
    BULLETIN D INFORMATIONS SCIENTIFIQUES ET TECHNIQUES, 1971, (156): : 39 - &
  • [10] ASSESSMENT OF NEUROMUSCULAR-TRANSMISSION BY THE EVOKED ACCELERATION RESPONSE - AN EVALUATION OF THE ACCURACY OF THE ACCELERATION TRANSDUCER IN COMPARISON WITH A FORCE DISPLACEMENT TRANSDUCER
    WERNER, MU
    NIELSEN, HK
    MAY, O
    DJERNES, M
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1988, 32 (05) : 395 - 400