Sensitive and Accurate Determination of Cobalt at Trace Levels by Slotted Quartz Tube-Flame Atomic Absorption Spectrometry Following Preconcentration with Dispersive Liquid-Liquid Microextraction

被引:7
|
作者
Deniz, Serenay [1 ]
Kasa, Aylin [1 ]
Sel, Sabriye [1 ]
Buyukpinar, Cagdas [1 ]
Bakirdere, Sezgin [1 ]
机构
[1] Yildiz Tech Univ, Dept Chem, TR-34349 Istanbul, Turkey
关键词
Cobalt; dispersive liquid-liquid microextraction (DLLME); slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS); WATER SAMPLES; CHROMATOGRAPHY; EXTRACTION;
D O I
10.1080/00032719.2018.1493737
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) was used as a sensitive technique for the determination of cobalt, an element has toxic effects on living organisms at high doses. For the preliminary preconcentration of cobalt prior to the analysis, dispersive liquid-liquid microextraction (DLLME) was used. The instrument is equipped with a SQT to further increase the sensitivity by increasing the residence time of cobalt atoms in the light path emitted by a hollow cathode lamp. In the complex formation step, pH, the volume of buffer solution, the concentration of 1,5-diphenylcarbazone, and the volume of ligand were optimized. In addition, all of the system parameters, including the type and volume of the extraction solvent, dispersant type and volume of solvent, type of salt and the volume for the dispersion liquid-liquid microextraction, were optimized to obtain the lowest detection limit. Under the optimum conditions, the detection power of FAAS was improved by a factor of 86.56 fold using DLLME-SQT-FAAS. The limit of detection for the DLLME-SQT-FAAS system was 0.97 mu g L-1. The applicability of the developed method was verified in tap and waste water samples by spiking measurements. The percentage recovery values for these were determined to be 91.7% and 111.0%, respectively.
引用
收藏
页码:745 / 753
页数:9
相关论文
共 50 条
  • [1] Determination of trace amount of cadmium using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry
    Firat, Merve
    Bakirdere, Sezgin
    Findikoglu, Maral Selin
    Kafa, Emine Betul
    Yazici, Elif
    Yolcu, Melda
    Buyukpinar, Cagdas
    Chormey, Dotse Selali
    Sel, Sabriye
    Turak, Fatma
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 129 : 37 - 41
  • [2] Sensitive determination of copper in water samples using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry
    Ozzeybek, Gozde
    Erarpat, Sezin
    Chormey, Dotse Selali
    Firat, Merve
    Buyukpinar, Cagdas
    Turak, Fatma
    Bakirdere, Sezgin
    MICROCHEMICAL JOURNAL, 2017, 132 : 406 - 410
  • [3] Trace determination of cobalt in biological fluids based on preconcentration with a new competitive ligand using dispersive liquid-liquid microextraction combined with slotted quartz tube-flame atomic absorption spectrophotometry
    Er, Elif Orturk
    Bakirdere, Emine Gulhan
    Unutkan, Tugce
    Bakirdere, Sezgin
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2018, 49 : 13 - 18
  • [4] An accurate determination method for cobalt in sage tea and cobalamin: Slotted quartz tube-flame atomic absorption spectrometry after preconcentration with switchable liquid-liquid microextraction using a Schiff base
    Yazici, Elif
    Firat, Merve
    Chormey, Dotse Selali
    Bakirdere, Emine Gulhan
    Bakirdere, Sezgin
    FOOD CHEMISTRY, 2020, 302
  • [5] Development and Validation of a Sensitive Method for Trace Nickel Determination by Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Dispersive Liquid-Liquid Microextraction
    Yolcu, Sukran Meida
    Firat, Merve
    Chormey, Dotse Selali
    Buyukpinar, Cagdas
    Turak, Fatma
    Bakirdere, Sezgin
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2018, 100 (05) : 715 - 719
  • [6] Determination of lead at trace levels in mussel and sea water samples using vortex assisted dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry
    Erarpat, Sezin
    Ozzeybek, Gozde
    Chormey, Dotse Selali
    Bakirdere, Sezgin
    CHEMOSPHERE, 2017, 189 : 180 - 185
  • [7] Combination of Slotted Quartz Tube Flame Atomic Absorption Spectrometry and Dispersive Liquid-Liquid Microextraction for the Trace Determination of Silver in Electroplating Rinse Bath
    Terzioglu, Duygu
    Dalgic Bozyigit, Gamze
    Firat Ayyildiz, Merve
    Chormey, Dotse Selali
    Bakirdere, Sezgin
    ANALYTICAL LETTERS, 2021, 54 (05) : 761 - 771
  • [8] Determination of trace nickel in chamomile tea and coffee samples by slotted quartz tube-flame atomic absorption spectrometry after preconcentration with dispersive liquid-liquid microextraction method using a Schiff base ligand
    Saylan, Meltem
    Zaman, Buse Tugba
    Bakirdere, Emine Gulhan
    Bakirdere, Sezgin
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 88
  • [9] Development and Validation of a Sensitive Method for Trace Nickel Determination by Slotted Quartz Tube Flame Atomic Absorption Spectrometry After Dispersive Liquid–Liquid Microextraction
    Şükran Melda Yolcu
    Merve Fırat
    Dotse Selali Chormey
    Çağdaş Büyükpınar
    Fatma Turak
    Sezgin Bakırdere
    Bulletin of Environmental Contamination and Toxicology, 2018, 100 : 715 - 719
  • [10] Development of an Accurate and Sensitive Analytical Method for the Determination of Cadmium at Trace Levels Using Dispersive Liquid-Liquid Microextraction Based on the Solidification of Floating Organic Drops Combined with Slotted Quartz Tube Flame Atomic Absorption Spectrometry
    Aydin, Ilgin
    Chormey, Dotse Selali
    Budak, Turkan
    Firat, Merve
    Turak, Fatma
    Bakirdere, Sezgin
    JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (03) : 843 - 847