New Insights into the Gelation Behavior of Polyethyleneimine Cross-Linking Partially Hydrolyzed Polyacrylamide Gels

被引:100
|
作者
Jia, Hu [1 ]
Zhao, Jin-Zhou [1 ]
Jin, Fa-Yang [1 ]
Pu, Wan-Fen [1 ]
Li, Yong-Ming [1 ]
Li, Ke-Xing [1 ]
Li, Ji-Mao [2 ]
机构
[1] SW Petr Univ, State Key Lab Oil & Gas Reservoir Geol & Exploita, Chengdu, Peoples R China
[2] Sinopec, NE Oil & Gas Branch, Changchun, Peoples R China
关键词
PREFORMED PARTICLE GEL; HIGH-TEMPERATURE; CONFORMANCE CONTROL; LINKED GEL; PERFORMANCE; SYSTEM; TRANSPORT; KINETICS;
D O I
10.1021/ie301818f
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Using polymer gel is still the mainstream technique of the chemical method for water shut-off in mature oilfield development. The gelation performance of polyethyleneimine (PEI) cross-linking partially hydrolyzed polyacrylamide (HPAM) gel was systematically investigated in this paper by using three types of molecular weight (M-w) HPAM. Results show that the gelant solution (the fluid solution of cross-linker and polymer that exists before gelation) can slightly gel even at room temperature and form a rudimentary 3D network structure for protecting the subsequent gelling. The main factors, including HPAM, PEI concentrations, HPAM M-w and total dissolved solids (TDS) to affect the gelation performance are also discussed. The gelation time is around 18-72 h at 65 degrees C, which is much longer than the commonly used chromium(III)-acetate cross-linking HPAM gel system. The gelation performance of the PEI/HPAM gel system is improved after flowing through porous media and shows the adverse law for a porous media sheared chromium(III)-acetate or phenol-formaldehyde cross-linking HPAM gel system. Atomic force microscopy (AFM) scanning results show that the microstructure of PEI/HPAM gel distributes a lot of cavities. Compared to the original premature gel (code B), the cavities are more uniform and regular after flowing through porous media. In addition, this study revealed that the presence of free oxygen in the uniform cavities of the weak crosslinked gel after flowing through porous media can accelerate the oxidation reaction to produce a darker brown gel. It also discusses how these new findings will affect the application of the gel system in the oil field.
引用
收藏
页码:12155 / 12166
页数:12
相关论文
共 50 条
  • [1] Influences of Fracture Aperture on the Water-Shutoff Performance of Polyethyleneimine Cross-Linking Partially Hydrolyzed Polyacrylamide Gels in Hydraulic Fractured Reservoirs
    Zhao, Jin-Zhou
    Jia, Hu
    Pu, Wan-Fen
    Liao, Ran
    [J]. ENERGY & FUELS, 2011, 25 (06) : 2616 - 2624
  • [2] Investigating the Effect of Several Parameters on the Gelation Behavior of Partially Hydrolyzed Polyacrylamide-Hexamine-Hydroquinone Gels
    Yadav, Upendra Singh
    Mahto, Vikas
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (28) : 9532 - 9537
  • [3] Rheological behavior of partially hydrolyzed polyacrylamide hydrogel produced by chemical gelation
    Zhang, Yanfang
    Gao, Pin
    Chen, Mengmeng
    Huang, Guangsu
    [J]. JOURNAL OF MACROMOLECULAR SCIENCE PART B-PHYSICS, 2008, 47 (01): : 26 - 38
  • [4] Cross-linking of partially hydrolyzed sesbania gum, property and characterization
    Yanping, Li
    Hongbo, Tang
    Qiumei, He
    Xiaoyang, Duan
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2020, 159 : 11 - 17
  • [5] Study on gelation of partially hydrolyzed polyacrylamide with titanium(IV)
    Cai, WS
    Huang, RH
    [J]. EUROPEAN POLYMER JOURNAL, 2001, 37 (08) : 1553 - 1559
  • [6] Behavior of partially hydrolyzed polyacrylamide/polyethyleneimine reinforced with coal fly ash for preformed particle hydrogels
    Pereira, Kaio A. B.
    Pereira, Kaique A. B.
    Oliveira, Priscila F.
    Mansur, Claudia R. E.
    [J]. JOURNAL OF APPLIED POLYMER SCIENCE, 2020, 137 (46)
  • [7] CROSS-LINKING STRUCTURE AND CHEMISTRY OF AQUEOUS CR+3/POLYACRYLAMIDE GELS
    ALBONICO, P
    LOCKHART, TP
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 340 - POLY
  • [8] POLYACRYLAMIDE GELS - MONITORING OF THE CROSS-LINKING POLYMERIZATION BY MEANS OF FLUORESCENT-PROBES
    PARRENO, J
    PIEROLA, IF
    [J]. POLYMER, 1990, 31 (09) : 1768 - 1771
  • [9] Synthesis of Hydrogel Nanocomposites Based on Partially Hydrolyzed Polyacrylamide, Polyethyleneimine, and Modified Clay
    Pereira, Kaique A. B.
    Aguiar, Kelly L. N. P.
    Oliveira, Priscila F.
    Vicente, Beatriz M.
    Pedroni, Lucas G.
    Mansur, Claudia R. E.
    [J]. ACS OMEGA, 2020, 5 (10): : 4759 - 4769
  • [10] CROSS-LINKING KINETICS IN POLYACRYLAMIDE NETWORKS
    TOBITA, H
    HAMIELEC, AE
    [J]. POLYMER, 1990, 31 (08) : 1546 - 1552