Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators

被引:1
|
作者
Benyon, R. [1 ]
Vicente, T. [1 ]
机构
[1] Inst Nacl Tecn Aeroespacial, Torrejon De Ardoz, Spain
关键词
Dew-point temperature; Humidity; Hygrometer; Standard humidity generator; Traceability; UNCERTAINTY;
D O I
10.1007/s10765-012-1342-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
The comparison of two high-range standard humidity generators used by Instituto Nacional de Tecnica Aeroespacial to realize dew-point temperature in the range from -10 degrees C to +95 degrees C has been performed using state-of-the art transfer standards and measurement procedures, over their overlapping range from -10 degrees C to +75 degrees C. The aim of this study is to investigate the level of agreement between the two generators, to determine any bias, and to quantify the level of consistency of the two realizations. The measurement procedures adopted to minimize the effect of the influence factors due to the transfer standards are described, and the results are discussed in the context of the declared calibration and measurement capabilities (CMCs).
引用
收藏
页码:1550 / 1558
页数:9
相关论文
共 50 条
  • [1] Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators
    R. Benyon
    T. Vicente
    [J]. International Journal of Thermophysics, 2012, 33 : 1550 - 1558
  • [2] The effect of water contamination on the dew-point temperature scale realization with humidity generators
    Vilbaste, M.
    Heinonen, M.
    Saks, O.
    Leito, I.
    [J]. METROLOGIA, 2013, 50 (04) : 329 - 336
  • [3] USE OF DEW-POINT TEMPERATURE IN HUMIDITY CALCULATIONS
    WOOD, LA
    [J]. JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1970, C 74 (3-4): : 117 - +
  • [4] Humidity dew-point transmitters
    不详
    [J]. MICRO, 1995, 13 (02): : 49 - 49
  • [5] HUMIDITY MONITOR AND DEW-POINT HYGROMETER
    PARKER, HW
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 338 : 4 - 4
  • [6] Advanced dew-point control system in two-pressure humidity generator to stabilize dew-point generation in low dew-point range
    Ishiwata, Naoya
    Abe, Hisashi
    [J]. AIP ADVANCES, 2022, 12 (03)
  • [7] Humidity measurement by dynamic dew-point detection
    Lang, W
    Glosch, H
    Billat, S
    Querrioux, T
    Kunze, M
    Ashauer, M
    Sandmaier, H
    [J]. BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1864 - 1866
  • [8] An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization
    Benyon, R.
    Boese, N.
    Mitter, H.
    Mutter, D.
    Vicente, T.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2012, 33 (8-9) : 1741 - 1757
  • [9] A new comparison method for dew-point generators
    Heinonen, M
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (12) : 1261 - 1265
  • [10] An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization
    R. Benyon
    N. Böse
    H. Mitter
    D. Mutter
    T. Vicente
    [J]. International Journal of Thermophysics, 2012, 33 : 1741 - 1757