Impact of delay after biopsy and post-biopsy haemorrhage on prostate cancer tumour detection using multi-parametric MRI: A multi-reader study

被引:25
|
作者
Rosenkrantz, A. B. [1 ]
Mussi, T. C. [1 ]
Hindman, N. [1 ]
Lim, R. P. [1 ]
Kong, M. X. [2 ]
Babb, J. S. [1 ]
Melamed, J. [2 ]
Taneja, S. S. [3 ]
机构
[1] NYU, Langone Med Ctr, Dept Radiol, New York, NY 10016 USA
[2] NYU, Langone Med Ctr, Dept Pathol, New York, NY 10016 USA
[3] NYU, Langone Med Ctr, Dept Urol, Div Urol Oncol, New York, NY 10016 USA
关键词
D O I
10.1016/j.crad.2012.08.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess impact of haemorrhage and delay after biopsy on prostate tumour detection using multi-parametric (MP) magnetic resonance imaging (MRI) assessment. MATERIALS AND METHODS: Forty-four patients underwent prostate MRI at 1.5 T using a pelvic phased-array coil, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging, before prostatectomy. Three radiologists independently reviewed images during four sessions [T2WI, DWI, DCE, and all parameters combined (MP-MRI)] to assess for tumour in each sextant. In a separate session, readers reviewed T1WI to score the extent of haemorrhage per sextant. Accuracy was assessed using logistic regression for correlated data. RESULTS: There was no significant difference in accuracy between readers for any session (p >= 0.166), and results were averaged across the three readers for remaining comparisons. Accuracy was significantly greater for MP-MRI than for any parameter alone (p <= 0.020). For T2WI alone, there was a trend toward decreased sensitivity in sextants with extensive haemorrhage (p = 0.072). However, accuracy, sensitivity, and specificity were otherwise similar for sextants with and without extensive haemorrhage for all sessions (p = 0.192-0.934). No session showed a significant improvement in accuracy, sensitivity, or specificity in cases with delay after biopsy of over 4 weeks compared with shorter delay. CONCLUSION: Extensive haemorrhage and short delay after biopsy did not negatively impact accuracy for tumour detection using MP-MRI. Further studies using MP-MRI protocols and interpretation schemes from other institutions are required to confirm these observations. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E83 / E90
页数:8
相关论文
共 50 条
  • [1] IMPACT OF MULTIFOCALITY ON PROSTATE CANCER DETECTION BY MULTI-PARAMETRIC MRI
    Tan, Nelly
    Le, Jesse
    Margolis, Daniel
    Lu, David
    King, Kevin
    Raman, Steven
    Reiter, Robert
    [J]. JOURNAL OF UROLOGY, 2014, 191 (04): : E588 - E589
  • [2] Diagnostic Accuracy of Multi-Parametric MRI and Freehand Transperineal Prostate Biopsy
    Newman, T.
    Stroman, L.
    Hadjipavlou, M.
    Mulhem, W.
    Ioannides, D.
    Chan, K.
    Milliken, C.
    Pinczes, T.
    Namdarian, B.
    Rusere, J.
    Patel, D.
    Mehan, N.
    Popert, R.
    Hammadeh, M.
    [J]. BRITISH JOURNAL OF SURGERY, 2020, 107 : 217 - 217
  • [3] Prospective evaluation of using multi-parametric MRI in cognitive fusion prostate biopsy compared to standard systematic 12-core biopsy in the detection of prostate cancer
    Lim, L. Y.
    Tan, G. H.
    Zainuddin, Z. M.
    Fam, X. I.
    Goh, E. H.
    Othman, S. S.
    Yahya, A.
    Singam, P.
    [J]. BJU INTERNATIONAL, 2018, 122 : 7 - 7
  • [4] Multi-parametric MRI Examinations for the Detection of Prostate Cancer
    Graewert, Stephanie
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (03): : 185 - 185
  • [5] The use of multi-parametric MRI in the detection of prostate cancer
    Bolton, E. M.
    Quinlan, M.
    Costelloe, J.
    O'Kelly, F.
    Galvin, D.
    Lennon, G.
    Mulvin, D.
    McMahon, C.
    Quinlan, D.
    [J]. BJU INTERNATIONAL, 2014, 114 : 21 - 22
  • [6] A boosting approach for prostate cancer detection using multi-parametric MRI
    Lemaitre, Guillaume
    Massich, Joan
    Marti, Robert
    Freixenet, Jordi
    Vilanova, Joan C.
    Walker, Paul M.
    Sidibe, Desire D.
    Meriaudeau, Fabrice
    [J]. TWELFTH INTERNATIONAL CONFERENCE ON QUALITY CONTROL BY ARTIFICIAL VISION, 2015, 9534
  • [8] Diagnostic accuracy of multi-parametric MRI and transrectal ultrasound-guided biopsy in prostate cancer
    Thompson, James E.
    Stricker, Phillip D.
    [J]. LANCET, 2017, 389 (10071): : 767 - 768
  • [9] COMPARISON OF THREE MULTI-PARAMETRIC MRI SCORING SYSTEMS FOR THE DETECTION OF PROSTATE CANCER ON MR/TRUS FUSION GUIDED PROSTATE BIOPSY
    Waingankar, Nikhil
    Salami, Simpa
    Stein, Joanna
    George, Arvin
    Yaskiv, Oksana
    Turkbey, Baris
    Ben-Levi, Eran
    Villani, Robert
    Kavoussi, Louis
    Siegel, David
    Rastinehad, Ardeshir
    [J]. JOURNAL OF UROLOGY, 2014, 191 (04): : E72 - E72
  • [10] Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory study
    Ahmed, Hashim U.
    Bosaily, Ahmed El-Shater
    Brown, Louise C.
    Gabe, Rhian
    Kaplan, Richard
    Parmar, Mahesh K.
    Collaco-Moraes, Yolanda
    Ward, Katie
    Hindley, Richard G.
    Freeman, Alex
    Kirkham, Alex P.
    Oldroyd, Robert
    Parker, Chris
    Emberton, Mark
    [J]. LANCET, 2017, 389 (10071): : 815 - 822