Can EuroSCORE II Predict the Mortality and Length of Intensive Care Unit Stay after Total Aortic Arch Replacement with Stented Elephant Trunk Implantation for DeBakey Type I Aortic Dissection?

被引:18
|
作者
Ge, Yipeng [1 ]
Sun, Lizhong [1 ]
Zhu, Junming [1 ]
Liu, Yongmin [1 ]
Cheng, Lijian [1 ]
Chen, Lei [1 ]
Zheng, Jun [1 ]
Li, Chengnan [1 ]
Liu, Wei [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiovasc Surg, Beijing Aort Dis Ctr, Beijing 100029, Peoples R China
来源
THORACIC AND CARDIOVASCULAR SURGEON | 2013年 / 61卷 / 07期
关键词
EuroSCORE II; mortality; aortic dissection; intensive care unit; VALIDATION; SURGERY; OUTCOMES;
D O I
10.1055/s-0033-1348197
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background EuroSCORE is a widely used objective risk scoring model. Objective The aim of this study was to evaluate the validation of EuroSCORE II for predicting in-hospital mortality and length of intensive care unit (ICU) stay after total aortic arch replacement with stented elephant trunk implantation for DeBakey Type I aortic dissection. Patients and Methods Between February 2009 and February 2012, data from 384 consecutive patients, who underwent aortic surgery using total aortic arch replacement with stented elephant trunk implantation, were collected retrospectively. EuroSCORE II was applied to predict mortality and length of ICU stay. The C-statistic was used to test discrimination of the model. Calibration was assessed with the Hosmer-Lemeshow goodness-of-fit statistic. Results The in-hospital mortality was 8.07%. The mean length of ICU stay was 3.06 days. A total of 75 patients remained at ICU for 5 days or more and 42 patients for 7 days or more. EuroSCORE II did not show good discriminatory ability in predicting mortality and length of ICU stay. The C-statistic of predicting mortality, ICU stay for 5 days or more, and ICU stay for 7 days or more were 0.49, 0.56, and 0.52, respectively. The calibration was poor for predicting mortality (p < 0.001), ICU stay for 5 days or more (p < 0.001), and ICU stay for 7 days or more (p < 0.001). Conclusion Although EuroSCORE II is the newest risk model for cardiac surgery, it is not accurate when it is applied for thoracic aortic surgery. A new risk evaluating system specially designed for aortic surgery should be developed in the future.
引用
收藏
页码:564 / 568
页数:5
相关论文
共 50 条
  • [1] Total Arch Replacement Combined with Stented Elephant Trunk Implantation for Acute Type A Aortic Dissection in an Octogenarian Patient
    Zheng, Zhifa
    Hu, Yuyuan
    Cheng, Xinmeng
    Yang, Tao
    Wu, Nan
    Yang, Lingbo
    Wang, Xuening
    HEART SURGERY FORUM, 2022, 25 (03): : E191 - E194
  • [2] Should the all elephant trunk" be skeletonized? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection
    Liu, ZG
    Sun, LZ
    Chang, Q
    Zhu, JM
    Dong, C
    Yu, CT
    Liu, YM
    Zhang, HT
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (01): : 107 - 113
  • [3] Total Arch Replacement With Stented Elephant Trunk Technique for Acute Type B Aortic Dissection Involving the Aortic Arch
    Zhao, Hai-Peng
    Zhu, Jun-Ming
    Ma, Wei-Guo
    Zheng, Jun
    Liu, Yong-Min
    Sun, Li-Zhong
    ANNALS OF THORACIC SURGERY, 2012, 93 (05): : 1517 - 1523
  • [4] Is total arch replacement combined with stented elephant trunk implantation justified for patients with chronic Stanford type A aortic dissection?
    Sun, Li-Zhong
    Qi, Rui-Dong
    Chang, Qian
    Zhu, Jun-Ming
    Liu, Yong-Min
    Yu, Chun-Tao
    Lv, Bin
    Zheng, Jun
    Tian, Liang-Xin
    Lu, Jin-Guo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (04): : 892 - 896
  • [5] Early and midterm outcomes of hemiarch replacement combined with stented elephant trunk in the management of acute DeBakey type I aortic dissection: Comparison with total arch replacement
    Shi, Enyi
    Gu, Tianxiang
    Yu, Yang
    Yu, Lei
    Wang, Chun
    Fang, Qin
    Zhang, Yuhai
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (05): : 2125 - 2131
  • [6] The stented elephant trunk procedure combined total arch replacement for Debakey I aortic dissection: operative result and follow-up
    Chen, Xin
    Huang, Fuhua
    Xu, Ming
    Wang, Liming
    Jiang, Yingsuo
    Xiao, Liqiong
    Chen, Xujun
    Qiu, Zhibing
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (05) : 594 - 598
  • [7] Total aortic arch replacement with the frozen elephant trunk procedure in acute DeBakey type I aortic dissections
    Shrestha, Malakh
    Haverich, Axel
    Martens, Andreas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 : 29 - 34
  • [8] Total Arch Replacement Combined With Stented Elephant Trunk Implantation A New "Standard" Therapy for Type A Dissection Involving Repair of the Aortic Arch?
    Sun, LiZhong
    Qi, RuiDong
    Zhu, JunMing
    Liu, YongMin
    Zheng, Jun
    CIRCULATION, 2011, 123 (09) : 971 - 978
  • [9] David reimplantation with simultaneous total arch replacement and stented elephant trunk for acute type A aortic dissection
    Li, Jun
    Sun, Yiping
    Zhou, Tianyu
    Wang, Yongshi
    Sun, Yongxin
    Lai, Hao
    Wang, Chunsheng
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 161 (06): : 2017 - +
  • [10] Successful total arch replacement with long elephant trunk for chronic aortic dissection (DeBakey IIIb)
    Shudo, Yasuhiro
    Taniguchi, Kazuhiro
    Matsue, Hajime
    Takahashi, Toshiki
    Toda, Koichi
    Hata, Hiroki
    Sawa, Yoshiki