Differences in Trunk Accelerometry Between Frail and Nonfrail Elderly Persons in Sit-to-Stand and Stand-to-Sit Transitions Based on a Mobile Inertial Sensor

被引:36
|
作者
Galan-Mercant, Alejandro [1 ]
Cuesta-Vargas, Antonio I. [1 ,2 ]
机构
[1] Univ Malaga, Dept Physiotherapy, Fac Hlth Sci, Av Martiricos S-N, Malaga 29009, Spain
[2] Queensland Univ Technol, Fac Hlth, Sch Clin Sci, Brisbane, Qld, Australia
来源
JMIR MHEALTH AND UHEALTH | 2013年 / 1卷 / 02期
关键词
frail syndrome; sit-to-stand; stand-to-sit; mobile phone; inertial sensor; FALL RISK; GO; VARIABILITY; RELIABILITY; KINEMATICS; BALANCE;
D O I
10.2196/mhealth.2710
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Clinical frailty syndrome is a common geriatric syndrome, which is characterized by physiological reserve decreases and increased vulnerability. The changes associated to ageing and frailties are associated to changes in gait characteristics and the basic functional capacities. Traditional clinical evaluation of Sit-to-Stand (Si-St) and Stand-to-Sit (St-Si) transition is based on visual observation of joint angle motion to describe alterations in coordination and movement pattern. The latest generation smartphones often include inertial sensors with subunits such as accelerometers and gyroscopes, which can detect acceleration. Objective: Firstly, to describe the variability of the accelerations, angular velocity, and displacement of the trunk during the Sit-to-Stand and Stand-to-Sit transitions in two groups of frail and physically active elderly persons, through instrumentation with the iPhone 4 smartphone. Secondly, we want to analyze the differences between the two study groups. Methods: A cross-sectional study that involved 30 subjects over 65 years, 14 frail and 16 fit subjects. The participants were classified with frail syndrome by the Fried criteria. Linear acceleration was measured along three orthogonal axes using the iPhone 4 accelerometer. Each subject performed up to three successive Si-St and St-Si postural transitions using a standard chair with armrest. Results: Significant differences were found between the two groups of frail and fit elderly persons in the accelerometry and angular displacement variables obtained in the kinematic readings of the trunk during both transitions. Conclusions: The inertial sensor fitted in the iPhone 4 is able to study and analyze the kinematics of the Si-St and St-Si transitions in frail and physically active elderly persons. The accelerometry values for the frail elderly are lower than for the physically active elderly, while variability in the readings for the frail elderly is also lower than for the control group.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Probabilistic identification of sit-to-stand and stand-to-sit with a wearable sensor
    Martinez-Hernandez, Uriel
    Dehghani-Sanij, Abbas A.
    [J]. PATTERN RECOGNITION LETTERS, 2019, 118 : 32 - 41
  • [2] Multi-parametric evaluation of sit-to-stand and stand-to-sit transitions in elderly people
    Ganea, R.
    Paraschiv-Ionescu, A.
    Buela, C.
    Rochat, S.
    Aminian, K.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2011, 33 (09) : 1086 - 1093
  • [3] Time measurement characterization of stand-to-sit and sit-to-stand transitions by using a smartphone
    Hernán A. González Rojas
    Pedro Chaná Cuevas
    Enrique E. Zayas Figueras
    Salvador Cardona Foix
    Antonio J. Sánchez Egea
    [J]. Medical & Biological Engineering & Computing, 2018, 56 : 879 - 888
  • [4] Time measurement characterization of stand-to-sit and sit-to-stand transitions by using a smartphone
    Gonzalez Rojas, Hernan A.
    Chana Cuevas, Pedro
    Zayas Figueras, Enrique E.
    Cardona Foix, Salvador
    Sanchez Egea, Antonio J.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (05) : 879 - 888
  • [5] Trunk muscle forces and spinal loads in persons with unilateral transfemoral amputation during sit-to-stand and stand-to-sit activities
    Shojaei, Iman
    Hendershot, Brad D.
    Acasio, Julian C.
    Dearth, Christopher L.
    Ballard, Matthew
    Bazrgari, Babak
    [J]. CLINICAL BIOMECHANICS, 2019, 63 : 95 - 103
  • [6] Differences In Muscle Synergy Patterns During Stand-to-Sit And Sit-to-Stand Tasks.
    Alighanbari, Mohsen
    Griffin, Lisa
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 240 - 240
  • [7] Sit-to-stand And Stand-to-sit Alterations In The Mild-to-moderate Knee Osteoarthritis For Elderly Women
    Wu, Xie
    Pan, Jiaohao
    Liu, Yu
    Li, Li
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 88 - 88
  • [8] Trunk biomechanical changes between the sit-to-stand and stand-to-sit performed at self-selected and fast speeds in stroke survivors
    Franco, Juliane
    Silva, Paula Fernanda de Sousa
    Menezes, Alice Rausch
    de Brito, Sherindan Ayessa Ferreira
    Faria, Christina Danielli Coelho de Morais
    [J]. DISABILITY AND REHABILITATION, 2024, 46 (18) : 4226 - 4233
  • [9] Kinematic Parameters to Evaluate Functional Performance of Sit-to-Stand and Stand-to-Sit Transitions Using Motion Sensor Devices: A Systematic Review
    Millor, Nora
    Lecumberri, Pablo
    Gomez, Marisol
    Martinez-Ramirez, Alicia
    Izquierdo, Mikel
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2014, 22 (05) : 926 - 936
  • [10] Mechanical work and energy of sit-to-stand and stand-to-sit transitions performed with traditional and dynamic office chair designs
    Zehr, Jackie D.
    Noguchi, Mamiko
    Fok, Donna J.
    Callaghan, Jack P.
    [J]. WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2023, 76 (01): : 303 - 313