Upconversion microparticles as time-resolved luminescent probes for multiphoton microscopy: desired signal extraction from the streaking effect

被引:13
|
作者
Pominova, Daria V. [1 ]
Ryabova, Anastasia V. [1 ,2 ]
Grachev, Pavel V. [1 ]
Romanishkin, Igor D. [1 ]
Kuznetsov, Sergei V. [1 ]
Rozhnova, Julia A. [1 ]
Yasyrkina, Daria S. [1 ]
Fedorov, Pavel P. [1 ]
Loschenov, Victor B. [1 ,2 ]
机构
[1] Russian Acad Sci, AM Prokhorov Gen Phys Inst, Vavilov St 38, Moscow 119991, Russia
[2] Natl Res Nucl Univ MEPhI, Moscow Engn Phys Inst, Kashirskoe Highway 31, Moscow 115409, Russia
关键词
upconversion; laser scanning microscopy; lifetime; deconvolution; TRANSITION-METAL; UPCONVERTING NANOCRYSTALS; POWER DEPENDENCE; NANOPARTICLES; LANTHANIDE; NANOPHOSPHORS; EMISSION; THERAPY; SYSTEMS; CELLS;
D O I
10.1117/1.JBO.21.9.096002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The great interest in upconversion nanoparticles exists due to their high efficiency under multiphoton excitation. However, when these particles are used in scanning microscopy, the upconversion luminescence causes a streaking effect due to the long lifetime. This article describes a method of upconversion microparticle luminescence lifetime determination with help of modified Lucy-Richardson deconvolution of laser scanning microscope (LSM) image obtained under near-IR excitation using nondescanned detectors. Determination of the upconversion luminescence intensity and the decay time of separate microparticles was done by intensity profile along the image fast scan axis approximation. We studied upconversion submicroparticles based on fluoride hosts doped with Yb3+-Er3+ and Yb3+-Tm3+ rare earth ion pairs, and the characteristic decay times were 0.1 to 1.5 ms. We also compared the results of LSM measurements with the photon counting method results; the spread of values was about 13% and was associated with the approximation error. Data obtained from live cells showed the possibility of distinguishing the position of upconversion submicroparticles inside and outside the cells by the difference of their lifetime. The proposed technique allows using the upconversion microparticles without shells as probes for the presence of OH- ions and CO2 molecules. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:11
相关论文
共 5 条
  • [1] Real-time digital signal processing in multiphoton and time-resolved microscopy
    Wilson, Jesse W.
    Warren, Warren S.
    Fischer, Martin C.
    OPTICAL BIOPSY XIV: TOWARD REAL-TIME SPECTROSCOPIC IMAGING AND DIAGNOSIS, 2016, 9703
  • [2] Time-resolved long-lived luminescence imaging method employing luminescent lanthanide probes with a new microscopy system
    Hanaoka, Kenjiro
    Kikuchi, Kazuya
    Kobayashi, Shigeru
    Nagano, Tetsuo
    Journal of the American Chemical Society, 2007, 129 (44): : 13502 - 13509
  • [3] Time-resolved long-lived luminescence imaging method employing luminescent lanthanide probes with a new microscopy system
    Hanaoka, Kenjiro
    Kikuchi, Kazuya
    Kobayashi, Shigeru
    Nagano, Tetsuo
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (44) : 13502 - 13509
  • [4] Flexible digital signal processing architecture for narrowband and spread-spectrum lock-in detection in multiphoton microscopy and time-resolved spectroscopy
    Wilson, Jesse W.
    Park, Jong Kang
    Warren, Warren S.
    Fischer, Martin C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (03):
  • [5] Pronounced non-condon effect as the origin of the quantum beat observed in the time-resolved absorption signal from excited-state cis-stilbene
    Ishii, Kunihiko
    Takeuchi, Satoshi
    Tahara, Tahei
    JOURNAL OF PHYSICAL CHEMISTRY A, 2008, 112 (11): : 2219 - 2227