Clinical and Radiological Outcomes after Total Shoulder Arthroplasty Using Custom-Made Glenoid Components: A Systematic Review

被引:1
|
作者
Gruber, Michael Stephan [1 ]
Schwarz, Tamara [2 ]
Lindorfer, Marlene [1 ]
Rittenschober, Felix [1 ]
Bischofreiter, Martin [1 ,3 ]
Hochreiter, Josef [1 ]
Ortmaier, Reinhold [1 ]
机构
[1] Paracelsus Med Univ Salzburg, Teaching Hosp, Vinzenzgrp Ctr Orthoped Excellence, Dept Orthoped Surg,Ordensklinikum Linz Barmherzige, A-4020 Linz, Austria
[2] Johannes Kepler Univ Linz, Fac Med, A-4020 Linz, Austria
[3] Clin Diakonissen Schladming, Dept Orthoped Surg, A-8970 Schladming, Austria
关键词
custom-made implant; shoulder arthroplasty; reverse total shoulder arthroplasty; glenoid bone loss; 3D printing; GLENOHUMERAL OSTEOARTHRITIS; QUANTIFYING SUCCESS; REVISION SURGERY; BONE; CLASSIFICATION; COMPLICATIONS; ARTHRITIS; DEFECTS; IMPLANT; CUFF;
D O I
10.3390/jcm11247268
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reverse total shoulder arthroplasty presents itself sometimes as challenging when it comes to addressing massive bone loss, either in primary or revision settings. Custom components recently have made their way into shoulder prosthetics and are meant to help in the case of extensive glenoid bone destruction. Because of strict indication and the fairly recent introduction of these implants, the usage of custom-made glenoid implants is not very common yet. However, the early results are promising. The purpose of this review was to summarize and analyze the available literature. Therefore, a systematic review was performed according to PRISMA guidelines. A comprehensive search of the databases PubMed, Cochrane, and Livivo was performed to screen for studies reporting on clinical and radiological outcomes of custom glenoid implants. Four studies with a total of 46 shoulders were included in this review. The mean patient age was 68.8 years and the mean time of follow-up was 24.3 months. The weighted means showed an increase in CMS (32.7 points), in ASES (39.8 points), in anteversion (67.4 degrees), and in abduction (51.9 degrees) and a decrease in VAS (5.4 points). Custom-made glenoid implants are therefore a viable option in cases of large combined glenoid bone loss, both in primary and revision shoulder arthroplasty.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Functional and Radiological Outcomes after Treatment with Custom-Made Glenoid Components in Revision Reverse Shoulder Arthroplasty
    Ortmaier, Reinhold
    Wierer, Guido
    Gruber, Michael Stephan
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [2] Custom-made glenoid implants in shoulder arthroplasty
    Petermann, M.
    Agneskirchner, J.
    [J]. ARTHROSKOPIE, 2021, 34 (05) : 366 - 376
  • [3] Anatomical total shoulder arthroplasty revision to reverse shoulder arthroplasty using convertible glenoid: a systematic review of clinical and radiological outcomes
    Ranieri, Riccardo
    Anzillotti, Giuseppe
    Delle Rose, Giacomo
    Borroni, Mario
    Garofalo, Raffaele
    Castagna, Alessandro
    [J]. INTERNATIONAL ORTHOPAEDICS, 2024, 48 (09) : 2411 - 2419
  • [4] Reimbursement of custom-made glenoid implants for shoulder arthroplasty
    Petermann, M.
    Agneskirchner, J.
    [J]. ARTHROSKOPIE, 2022, 35 (01) : 67 - 69
  • [5] Early outcomes of augmented glenoid components in anatomic total shoulder arthroplasty: a systematic review
    Sheth, Ujash
    Lee, James Y. J.
    Nam, Diane
    Henry, Patrick
    [J]. SHOULDER & ELBOW, 2022, 14 (03) : 237 - 247
  • [6] Use of custom glenoid components for reverse total shoulder arthroplasty
    Apiwatanakul, Punyawat
    Meshram, Prashant
    Harris, Andrew B.
    Bervell, Joel
    Lukasiewicz, Piotr
    Maxson, Ridge
    Best, Matthew J.
    McFarland, Edward G.
    [J]. CLINICS IN SHOULDER AND ELBOW, 2023, 26 (04): : 343 - 350
  • [7] Outcomes of patients undergoing anatomical total shoulder arthroplasty with augmented glenoid components - a systematic review
    Prada, Carlos
    Al-Mohrej, Omar A.
    Siddiqui, Salwa
    Khan, Moin
    [J]. SHOULDER & ELBOW, 2023,
  • [8] Custom-made reverse shoulder arthroplasty for severe glenoid bone loss: review of the literature and our preliminary results
    G. Porcellini
    G. M. Micheloni
    L. Tarallo
    P. Paladini
    G. Merolla
    F. Catani
    [J]. Journal of Orthopaedics and Traumatology, 2021, 22
  • [9] Custom-made reverse shoulder arthroplasty for severe glenoid bone loss: review of the literature and our preliminary results
    Porcellini, G.
    Micheloni, G. M.
    Tarallo, L.
    Paladini, P.
    Merolla, G.
    Catani, F.
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 22 (01)
  • [10] Early outcomes of using custom-made augments in revision total hip arthroplasty
    Tikhilov, R. M.
    Dzhavadov, A. A.
    Demin, A. S.
    Bilyk, S. S.
    Denisov, A. O.
    Shubnyakov, I. I.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2022, 46 (10) : 2229 - 2235