3D position estimation using an artificial neural network for a continuous scintillator PET detector

被引:57
|
作者
Wang, Y. [1 ]
Zhu, W. [1 ]
Cheng, X. [1 ]
Li, D. [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 05期
基金
中国国家自然科学基金;
关键词
DEPTH;
D O I
10.1088/0031-9155/58/5/1375
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous crystal based PET detectors have features of simple design, low cost, good energy resolution and high detection efficiency. Through single-end readout of scintillation light, direct three-dimensional (3D) position estimation could be another advantage that the continuous crystal detector would have. In this paper, we propose to use artificial neural networks to simultaneously estimate the plane coordinate and DOI coordinate of incident. photons with detected scintillation light. Using our experimental setup with an '8 + 8' simplified signal readout scheme, the training data of perpendicular irradiation on the front surface and one side surface are obtained, and the plane (x, y) networks and DOI networks are trained and evaluated. The test results show that the artificial neural network for DOI estimation is as effective as for plane estimation. The performance of both estimators is presented by resolution and bias. Without bias correction, the resolution of the plane estimator is on average better than 2 mm and that of the DOI estimator is about 2 mm over the whole area of the detector. With bias correction, the resolution at the edge area for plane estimation or at the end of the block away from the readout PMT for DOI estimation becomes worse, as we expect. The comprehensive performance of the 3D positioning by a neural network is accessed by the experimental test data of oblique irradiations. To show the combined effect of the 3D positioning over the whole area of the detector, the 2D flood images of oblique irradiation are presented with and without bias correction.
引用
收藏
页码:1375 / 1390
页数:16
相关论文
共 50 条
  • [1] Depth of Interaction Estimation Using Artificial Neural Network for Continuous Crystal PET Detector
    Wang Yonggang
    Cheng Xinyi
    Li Deng
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1260 - 1263
  • [2] Electronics for Monolithic Scintillator PET Detector Modules Based on Neural Network Position Estimators
    Wang Yonggang
    Du Junwei
    Zhou Zhonghui
    Yang Yang
    Zhang Lijun
    Bruyndonckx, Peter
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 554 - +
  • [3] Performance Study of Neural Network Position Estimators for the Monolithic Scintillator PET detector Modules
    Du Junwei
    Wang Yonggang
    Zhang Lijun
    Chen Jun
    Yang Yang
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010,
  • [4] Pulse discrimination of scintillator detector with artificial neural network
    College of Physics, Sichuan University, Chengdu 610064, China
    Hedianzixue Yu Tance Jishue, 2006, 4 (458-461+545):
  • [5] Ensemble of neural networks for 3D position estimation in monolithic PET detectors
    Iborra, A.
    Gonzalez, A. J.
    Gonzalez-Montoro, A.
    Bousse, A.
    Visvikis, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [6] An FPGA-Based Real-Time Maximum Likelihood 3D Position Estimation for a Continuous Crystal PET Detector
    Wang, Yonggang
    Xiao, Yong
    Cheng, Xinyi
    Li, Deng
    Wang, Liwei
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 37 - 43
  • [7] 3D MULTIMEDIA PROTECTION USING ARTIFICIAL NEURAL NETWORK
    Motwani, Mukesh C.
    Bryant, Bobby D.
    Dascalu, Sergiu M.
    Harris, Frederick C., Jr.
    2010 7TH IEEE CONSUMER COMMUNICATIONS AND NETWORKING CONFERENCE-CCNC 2010, 2010, : 1185 - 1189
  • [8] 3D Nonlinear Least Squares Position Estimation in a Monolithic Scintillator Block
    Li, Zhi
    Bruyndonckx, Peter
    Wedrowski, Mateusz
    Vandersteen, Gerd
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2654 - +
  • [9] A feasibility study on 3D interaction position estimation using deep neural network in Cherenkov-based detector: a Monte Carlo simulation study
    Hashimoto, Fumio
    Ote, Kibo
    Ota, Ryosuke
    Hasegawa, Tomoyuki
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [10] High-precision position estimation in PET using artificial neural networks
    Mateo, F.
    Aliaga, R. J.
    Ferrando, N.
    Martinez, J. D.
    Herrero, V.
    Lerche, Ch. W.
    Colom, R. J.
    Monzo, J. M.
    Sebastia, A.
    Gadea, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 366 - 369