Design and Implementation of a Multifunction Wearable Device to Monitor Sleep Physiological Signals

被引:18
|
作者
Liao, Lun-De [1 ]
Wang, Yuhling [1 ]
Tsao, Yung-Chung [1 ]
Wang, I-Jan [2 ]
Jhang, De-Fu [1 ,3 ]
Chuang, Chiung-Cheng [1 ,3 ]
Chen, Sheng-Fu [1 ]
机构
[1] Natl Hlth Res Inst, Inst Biomed Engn & Nanomed, Zhunan 35053, Taiwan
[2] Tunghai Univ, Dept Ind Engn & Enterprise Informat, Taichung 407224, Taiwan
[3] Chung Yuan Christian Univ, Coll Engn, Dept Biomed Engn, Taoyuan 32023, Taiwan
关键词
Internet of Things (IoT); physiological signals; sleep physiological signals; wearable device; HEART-RATE; NOISE; ACTIWATCH2; APNEA; PPG;
D O I
10.3390/mi11070672
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a wearable device built on an Adafruit Circuit Playground Express (CPE) board and integrated with a photoplethysmographic (PPG) optical sensor for heart rate monitoring and multiple embedded sensors for medical applications-in particular, sleep physiological signal monitoring. Our device is portable and lightweight. Due to the microcontroller unit (MCU)-based architecture of the proposed device, it is scalable and flexible. Thus, with the addition of different plug-and-play sensors, it can be used in many applications in different fields. The innovation introduced in this study is that with additional sensors, we can determine whether there are intermediary variables that can be modified to improve our sleep monitoring algorithm. Additionally, although the proposed device has a relatively low cost, it achieves substantially improved performance compared to the commercially available Philips ActiWatch2 wearable device, which has been approved by the Food and Drug Administration (FDA). To assess the reliability of our device, we compared physiological sleep signals recorded simultaneously from volunteers using both our device and ActiWatch2. Motion and light detection data from our device were shown to be correlated to data simultaneously collected using the ActiWatch2, with correlation coefficients of 0.78 and 0.89, respectively. For 7 days of continuous data collection, there was only one instance of a false positive, in which our device detected a sleep interval, while the ActiWatch2 did not. The most important aspect of our research is the use of an open architecture. At the hardware level, general purpose input/output (GPIO), serial peripheral interface (SPI), integrated circuit ((IC)-C-2), and universal asynchronous receiver-transmitter (UART) standards were used. At the software level, an object-oriented programming methodology was used to develop the system. Because the use of plug-and-play sensors is associated with the risk of adverse outcomes, such as system instability, this study heavily relied on object-oriented programming. Object-oriented programming improves system stability when hardware components are replaced or upgraded, allowing us to change the original system components at a low cost. Therefore, our device is easily scalable and has low commercialization costs. The proposed wearable device can facilitate the long-term tracking of physiological signals in sleep monitoring and related research. The open architecture of our device facilitates collaboration and allows other researchers to adapt our device for use in their own research, which is the main characteristic and contribution of this study.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Wearable computer as a multi-parametric monitor for physiological signals
    Conway, JCD
    Coelho, CJN
    da Silva, DC
    Fernandes, AO
    Andrade, LCG
    Carvalho, HS
    IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 236 - 242
  • [2] A biomedical wearable device for remote monitoring of physiological signals
    Coelho, CJN
    Fernandes, AO
    Conway, JCD
    Correa, FL
    Carvalho, HS
    Mata, JM
    ETFA 2003: IEEE CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION, VOL 2, PROCEEDINGS, 2003, : 708 - 713
  • [3] Research for multi-user wearable monitor system of physiological signals
    Tu, Qiaoling
    2007 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS I-V, CONFERENCE PROCEEDINGS, 2007, : 2721 - 2725
  • [4] Design and Implementation of Monitor Tester for Validation of ECG Signals
    Kasik, Vladimir
    Penhaker, Marek
    Kubicek, Jan
    Cerny, Martin
    Augustynek, Martin
    Oczka, David
    Krestanova, Alice
    PROCEEDINGS OF THE 12TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 1 (BIODEVICES), 2019, : 127 - 133
  • [5] Design of a wearable device for physiological parameter monitoring in a COVID setting
    De Santis, M.
    Barcali, E.
    Bardacci, Y.
    Rasero, L.
    Bambi, S.
    Bocchi, L.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7352 - 7355
  • [6] Wearable Device to Monitor Sheep Behavior
    Campiotti, Victoria
    Finozzi, Nicolas
    Irazoqui, Juan
    Cabrera, Varinia
    Ungerfeld, Rodolfo
    Oreggioni, Julian
    IEEE EMBEDDED SYSTEMS LETTERS, 2023, 15 (02) : 89 - 92
  • [7] A wearable device to monitor ocular comfort
    Read, Michael L.
    Morgan, Philip B.
    Maldonado-Codina, Carole
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (05): : 569 - 574
  • [8] DESIGN AND IMPLEMENTATION OF A MULTI SENSORS SELF SUSTAINABLE WEARABLE DEVICE
    Porcarelli, Danilo
    Donati, Irene
    Nehani, Jetmir
    Brunelli, Davide
    Magno, Michele
    Benini, Luca
    2014 6TH EUROPEAN EMBEDDED DESIGN IN EDUCATION AND RESEARCH CONFERENCE (EDERC), 2014, : 16 - 20
  • [9] Design, implementation and analysis of wearable biomedical assistance device for elderly
    Sabitha R.
    Sukanya S.
    Piranava T.
    International Journal of Information and Communication Technology, 2017, 10 (03) : 350 - 363
  • [10] Design and Implementation of Wearable Device for Neuropathic Diabetic Foot Patients
    Madavi, Monali V.
    Giripunje, Shubhangi D.
    2015 7TH INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ENGINEERING & TECHNOLOGY (ICETET), 2015, : 23 - 27