Fatigue and durability of Nitinol stents

被引:264
|
作者
Pelton, A. R. [1 ]
Schroeder, V. [1 ]
Mitchell, M. R. [2 ]
Gong, Xiao-Yan [3 ]
Barney, M. [1 ]
Robertson, S. W. [4 ]
机构
[1] Nitinol Devices & Components, Fremont, CA 94539 USA
[2] Mech & Mat Consulting LLC, Flagstaff, AZ 86004 USA
[3] Med Implant Mech LLC, Aliso Viejo, CA 92656 USA
[4] Cordis Corp, Fremont, CA USA
关键词
Nitinol; Fatigue; Constant-life diagrams; Stents;
D O I
10.1016/j.jmbbm.2007.08.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents; after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, the cyclic fatigue and durability properties of Nitinol-based endovascular stents are discussed in terms of an engineering-based experimental testing program. in this paper, the combined effects of cardiac pulsatile fatigue and stent-vessel oversizing are evaluated for application to both stents and stent subcomponents. In particular, displacement-controlled fatigue tests were performed on stent-like specimens processed from Nitinol microtubing. Fatigue data were collected with combinations of simulated oversizing conditions and pulsatile cycles that were identified by computer modeling of the stent that mimic in vivo deformation conditions. These data are analyzed with non-linear finite element computations and are illustrated with strainlife and strain-based constant-life diagrams. The utility of this approach is demonstrated in conjunction with 10 million cycle pulsatile fatigue tests of Cordis SMART Control (R) Nitinol self-expanding stents to calculate fatigue safety factors and thereby predict in vivo fatigue resistance. These results demonstrate the non-linear constant fatigue-life response of Nitinol stents, whereby, contrary to conventional engineering materials, the fatigue life of Nitinol is observed to increase with increasing mean strain. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:153 / 164
页数:12
相关论文
共 50 条
  • [1] THE INFLUENCE OF NITINOL ‘MICROPURITY’ ON MEDICAL IMPLANT DURABILITY The effects of Nitinol micropurity on the durability of superficial femoral artery stents offers a potential way to enhance durability and reduce fatigue fractures
    Pelton A.R.
    Pelton S.M.
    Ulmer J.
    Plaskonka K.
    Keck A.
    Mitchell M.R.
    Saffari P.
    Advanced Materials and Processes, 2020, 178 (07): : 35 - 37
  • [2] FATIGUE BEHAVIOR CHARACTERIZATION OF NITINOL FOR PERIPHERAL STENTS
    Petrini, Lorenza
    Wu, Wei
    Dordoni, Elena
    Meoli, Alessio
    Migliavacca, Francesco
    Pennati, Giancarlo
    FUNCTIONAL MATERIALS LETTERS, 2012, 5 (01)
  • [3] Computational Study of Axial Fatigue for Peripheral Nitinol Stents
    Alessio Meoli
    Elena Dordoni
    Lorenza Petrini
    Francesco Migliavacca
    Gabriele Dubini
    Giancarlo Pennati
    Journal of Materials Engineering and Performance, 2014, 23 : 2606 - 2613
  • [4] Computational Study of Axial Fatigue for Peripheral Nitinol Stents
    Meoli, Alessio
    Dordoni, Elena
    Petrini, Lorenza
    Migliavacca, Francesco
    Dubini, Gabriele
    Pennati, Giancarlo
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2014, 23 (07) : 2606 - 2613
  • [5] Optimization Of The Fatigue Resistance Of Nitinol Stents Through Shot Peening
    Dimakos, Konstantinos
    Mariotto, Andrea
    Giacosa, Fausto
    21ST EUROPEAN CONFERENCE ON FRACTURE, (ECF21), 2016, 2 : 1522 - 1529
  • [6] Nitinol for stents
    Rapp, Bob
    MATERIALS TODAY, 2004, 7 (05) : 13 - 13
  • [7] Fatigue Analysis of Nitinol Peripheral Artery Stents Under Complex Loads
    Chen, Yanlong
    Feng, Haiquan
    Zhang, Hailu
    Su, Juan
    Wang, Lin
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2025, 19 (01):
  • [8] The Impact of Fatigue Testing and Surface Processing on Nickel Release in Nitinol Stents
    Nagaraja S.
    Chandrasekar V.
    Ormonde D.
    Hickey H.
    Lipschultz K.
    Chao C.
    Vilendrer K.
    Pelton A.R.
    Nagaraja, Srinidhi (srinidhi.nagaraja@g-rau.com), 2018, Springer (04) : 462 - 471
  • [9] Accelerated in vitro durability testing of nonvascular Nitinol stents based on the electrical potential sensing method
    Park, Chan-Hee
    Tijing, Leonard D.
    Pant, Hem Raj
    Kim, Tae-Hyung
    Amarjargal, Altangerel
    Kim, Han Joo
    Kim, Cheol Sang
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2013, 112 (04): : 919 - 926
  • [10] Durability of a sutureless endovascular stent-graft based on nitinol stents bonded to a nanocomposite polymer
    Desai, M.
    Bakhshi, R.
    Darbyshire, A.
    Ahmed, M.
    Eaton-Evans, J.
    Zhou, Xiang
    You, Zhong
    Seifalian, A. M.
    Hamilton, G.
    BRITISH JOURNAL OF SURGERY, 2011, 98 : 32 - 33