Results of 200 Consecutive Ceramic-on-Ceramic Cementless Hip Arthroplasties in Patients Up To 50 Years of Age: A 5-24 Years of Follow-Up Study

被引:21
|
作者
Solarino, Giuseppe [1 ]
Zagra, Luigi [2 ]
Piazzolla, Andrea [1 ]
Morizio, Arcangelo [1 ]
Vicenti, Giovanni [1 ]
Moretti, Biagio [1 ]
机构
[1] Univ Bari Aldo Moro, AOU Policlin Consorziale, Sch Med, Dept Basic Med Sci Neurosci & Organs Sense, Bari, Italy
[2] IRCCS Ist Ortoped Galeazzi, Hip Dept, Milan, Italy
来源
JOURNAL OF ARTHROPLASTY | 2019年 / 34卷 / 07期
关键词
total hip arthroplasty; total hip replacement; ceramic-on-ceramic; wear; tribology; BEARING; FRACTURES; ALUMINA; REVISION; SURFACES; RISK;
D O I
10.1016/j.arth.2019.01.057
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic (CoC) bearings due to their mechanical properties can be used in primary total hip arthroplasty (THA) especially in young patients requiring a long-lasting implant. The goal of this study is to analyze the results of a series of 200 consecutive CoC THAs in patients aged 50 years or less at the time of surgery. Methods: A retrospective study was conducted on the first 200 consecutive CoC arthroplasties performed using the direct lateral approach on 105 females and 81 males (14 bilateral cases) with an average age of 44.2 (16-50) years. The diagnosis was primary or post-traumatic osteoarthritis in 94 cases, avascular necrosis of the femoral head in 47, displaced intracapsular femoral neck fracture in 29, osteoarthritis secondary to developmental dysplasia of the hip/Legg-Calve-Perthes disease/slipped capital femoral epiphysis in 20, and rheumatic diseases in 10 cases. The preoperative Harris Hip Score was 32.5 on average (range 15-55). All the implants were cementless. In 177 THAs the coupling was alumina-on-alumina, and in 23 cases the coupling was AMC-on-AMC (alumina matrix composite). Results: Twenty-five patients with 28 THAs were lost at the final follow-up, 2 stems were revised due to subsidence, 1 cup was revised due to malposition, 1 femoral head was changed because of impingement, and 1 THA was revised for periprosthetic infection. Three patients sustained a Vancouver B1 periprosthetic femoral fracture. At the final follow-up (mean 14.9 years; minimum 5 years to maximum 24 years), 172 THAs were eligible for clinical and radiographic evaluation: none was revised for wear and/or breakage of the ceramic components. Harris Hip Score rose up to a mean value of 90.1 (52-100). Conclusion: The present report demonstrates that CoC coupling offers excellent long-term results in THA performed in young patients with very low wear and no adverse effects caused by the material. (c) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:S232 / S237
页数:6
相关论文
共 50 条
  • [1] Cementless total hip arthroplasties using ceramic-on-ceramic articulation in young patients - A minimum 5-year follow-up study
    Huo, MH
    Martin, RP
    Zatorski, LE
    Keggi, KJ
    JOURNAL OF ARTHROPLASTY, 1996, 11 (06): : 673 - 678
  • [2] Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic Bearing Results After a Minimum of Twenty Years of Follow-up
    Petsatodis, George E.
    Papadopoulos, Pericles P.
    Papavasiliou, Kyriakos A.
    Hatzokos, Ippokratis G.
    Agathangelidis, Filon G.
    Christodoulou, Anastasios G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (03): : 639 - 644
  • [3] Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty
    Chevillotte, Christophe
    Pibarot, Vincent
    Carret, Jean-Paul
    Bejui-Hugues, Jacques
    Guyen, Olivier
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (11) : 1599 - 1604
  • [4] Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty
    Christophe Chevillotte
    Vincent Pibarot
    Jean-Paul Carret
    Jacques Bejui-Hugues
    Olivier Guyen
    International Orthopaedics, 2011, 35 : 1599 - 1604
  • [5] Alumina ceramic-on-ceramic hybrid total hip arthroplasty. A median of 15 years follow-up
    Farhan-Alanie, Omer M. H.
    Hrycaiczuk, Alex
    Tinning, Craig
    Jones, Bryn
    Stark, Andrew
    Bryceland, Kevin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (06): : 1127 - 1136
  • [6] Clinical results at 10 years of minimum follow-up with the ABG 2 hip arthroplasty, matched with ceramic-on-ceramic bearings
    Coulomb, Remy
    Mansour, Jad
    Essig, Jerome
    Asencio, Gerard
    Kouyoumdjian, Pascal
    SICOT-J, 2022, 8
  • [7] Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
    Malerba Giuseppe
    Basilico Mattia
    Bonfiglio Nadia
    Vitiello Raffaele
    Ruberto Pasquale
    D’ Adamio Stefano
    Sirgiovanni Mattia
    De Santis Vincenzo
    Maccauro Giulio
    BMC Musculoskeletal Disorders, 22
  • [8] Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up
    Giuseppe, Malerba
    Mattia, Basilico
    Nadia, Bonfiglio
    Raffaele, Vitiello
    Pasquale, Ruberto
    Stefano, D' Adamio
    Mattia, Sirgiovanni
    Vincenzo, De Santis
    Giulio, Maccauro
    BMC MUSCULOSKELETAL DISORDERS, 2022, 22 (SUPPL 2)
  • [9] Alumina ceramic-on-ceramic hybrid total hip arthroplasty. A median of 15 years follow-up
    Omer M. H. Farhan-Alanie
    Alex Hrycaiczuk
    Craig Tinning
    Bryn Jones
    Andrew Stark
    Kevin Bryceland
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1127 - 1136
  • [10] Ceramic-Ceramic Hip Arthroplasty for Osteonecrosis Average 5-year Follow-up in Patients Less Than 50 Years of Age
    Evangelista, Perry J.
    Kamath, Atul F.
    Aversano, Francis J.
    Silvestre, Jason
    Lee, Gwo-Chin
    Nelson, Charles L.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2015, 73 (01): : 42 - 45