Sulfated beta-cyclodextrin (SCD)-coated zirconia monolith was used as the chiral stationary phase in capillary electrochromatography for enantiomeric separation of basic chiral compounds. SCD adsorbed on the zirconia surface provided a stable chiral stationary phase in reversed-phase eluents. Retention, chiral selectivity and resolution of a set of six basic chiral compounds were measured in eluents of varying pH, composition of methanol and buffer. Optimum mobile phase condition for the separation of the compounds was found to be methanol content of 30%, buffer concentration of 30 mM and pH of 4.0.
机构:
Beijing Univ Chinese Med, Sch Chinese Pharm, Beijing 100102, Peoples R ChinaBeijing Univ Chinese Med, Sch Chinese Pharm, Beijing 100102, Peoples R China
Yuan, Ruijuan
Wang, Yan
论文数: 0|引用数: 0|
h-index: 0|
机构:
Tianjin Univ, Sch Pharmaceut Sci & Technol, Tianjin 300072, Peoples R ChinaBeijing Univ Chinese Med, Sch Chinese Pharm, Beijing 100102, Peoples R China
Wang, Yan
Ding, Guosheng
论文数: 0|引用数: 0|
h-index: 0|
机构:
Tianjin Univ, Sch Pharmaceut Sci & Technol, Tianjin 300072, Peoples R ChinaBeijing Univ Chinese Med, Sch Chinese Pharm, Beijing 100102, Peoples R China