Contrast Agent Dose Effects in Cerebral Dynamic Susceptibility Contrast Magnetic Resonance Perfusion Imaging

被引:18
|
作者
Alger, Jeffry R. [1 ,2 ,3 ,4 ]
Schaewe, Timothy J. [3 ]
Lai, Tom C. [1 ]
Frew, Andrew J. [1 ]
Vespa, Paul M. [3 ,5 ]
Etchepare, Maria [5 ]
Liebeskind, David S. [3 ]
Saver, Jeffrey L. [3 ]
Kidwell, S. Chelsea [3 ,6 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Neurol, Ahmanson Lovelace Brain Mapping Ctr, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Stroke Ctr, Dept Neurol, Los Angeles, CA 90095 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Brain Res Inst, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Div Neurosurg, Los Angeles, CA 90095 USA
[6] Georgetown Univ, Dept Neurol, Washington, DC USA
关键词
dynamic Susceptibility contrast; magnetic resonance imaging; brain; perfusion; contrast agent; dose; MRI BOLUS TRACKING; HIGH-RESOLUTION MEASUREMENT; ARTERIAL INPUT FUNCTION; BRAIN QUANTITATIVE CBF; BLOOD-FLOW; SIGNAL CHANGE; ENHANCED MRI; TISSUE; DELAY; DISPERSION;
D O I
10.1002/jmri.21613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study the contrast. agent dose sensitivity of hemodynamic parameters derived from brain dynamic susceptibility contrast MRI (DSC-MRI). Materials and Methods: Sequential DSC-MRI (1.5T gradient-echo echo-planar imaging using an echo time of 61-64 msec) was performed using contrast agent closes of 0.1 and 0.2 mmol/kg delivered at a fixed rate of 5.0 mL/second ill 12 normal subjects and 12 stroke patients. Results: 1) Arterial signal showed the expected doubling in relaxation response (Delta R2*) to dose doubling. 2) The brain signal showed a less than doubled Delta R2* response to dose doubling. 3) The 0.2 mmol/kg dose Studies subtly underestimated cerebral blood volume (CBV) and cerebral blood flow (CBF) relative to the 0.1 mmol/kg studies. 4) In the range of low CBV and CBF. the 0.2 mmol/kg studies over-estimated the CBV and CBF compared with the 0.1 niniol/kg studies. 5) The 0.1 mmol/kg studies reported larger ischemic Volumes in stroke. Conclusion: Subtle but statistically significant dose sensitivities were found. Therefore. it is advisable to carefully control the contrast agent dose when DSC-MRI is used in clinical trials. The study also suggests that a 0.1 mmol/kg dose is adequate for hemodynamic measurements.
引用
收藏
页码:52 / 64
页数:13
相关论文
共 50 条
  • [1] The impact of partial-volume effects in dynamic susceptibility contrast magnetic resonance perfusion imaging
    Chen, JJ
    Smith, MR
    Frayne, R
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (03) : 390 - 399
  • [2] Dynamic Susceptibility Contrast Perfusion Magnetic Resonance Imaging Demonstrates Reduced Periventricular Cerebral Blood Flow in Dogs with Ventriculomegaly
    Schmidt, Martin J.
    Kolecka, Malgorzata
    Kirberger, Robert
    Hartmann, Antje
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2017, 4
  • [3] Cerebral perfusion in infants and neonates: preliminary results obtained using dynamic susceptibility contrast enhanced magnetic resonance imaging
    Tanner, SF
    Cornette, L
    Ramenghi, LA
    Miall, LS
    Ridgway, JP
    Smith, MA
    Levene, MI
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2003, 88 (06): : F525 - F530
  • [4] Dynamic susceptibility contrast perfusion magnetic resonance imaging in patients with symptomatic unilateral middle cerebral artery stenosis or occlusion
    Lu, Jie
    Li, Kuncheng
    Zhang, Miao
    Jiao, Liqun
    [J]. ACTA RADIOLOGICA, 2007, 48 (03) : 335 - 340
  • [5] Measurement of cerebral mean transit time by dynamic susceptibility contrast magnetic resonance imaging
    Kamba, M
    Suto, Y
    Ogawa, T
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (03) : 170 - 173
  • [6] Cerebral perfusion in infants and neonates: Preliminary results obtained using Dynamic Susceptibility Contrast Enhanced Magnetic Resonance imaging
    Cornette, LM
    Tanner, SF
    Ramenghi, LA
    Miall, LS
    Levene, MI
    [J]. PEDIATRIC RESEARCH, 2003, 53 (04) : 448A - 448A
  • [7] Applications of dynamic susceptibility contrast magnetic resonance imaging in neuropsychiatry
    Levin, JM
    Ross, MH
    Harris, G
    Renshaw, PF
    [J]. NEUROIMAGE, 1996, 4 (03) : S147 - S162
  • [8] Measurement of bioreactor perfusion using dynamic contrast agent-enhanced magnetic resonance imaging
    Thelwall, PE
    Neves, AA
    Brindle, KM
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2001, 75 (06) : 682 - 690
  • [9] Perfusion Dynamic Susceptibility Contrast and Dynamic Contrast-Enhanced MR Imaging
    Ibrahim, Mohannad
    Ul Ghazi, Talha
    Bapuraj, Jayapalli Rajiv
    Srinivasan, Ashok
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 515 - 526
  • [10] Dynamic susceptibility MR perfusion imaging of the brain: not a question of contrast agent molarity
    Panara, Valentina
    Chiacchiaretta, Piero
    Rapino, Matteo
    Maruotti, Valerio
    Parenti, Matteo
    Piccirilli, Eleonora
    Pizzi, Andrea Delli
    Caulo, Massimo
    [J]. NEURORADIOLOGY, 2022, 64 (04) : 685 - 692