Preparation of leukodepleted platelet concentrates from pooled buffy coats:: Prestorage filtration with Autostop™BC

被引:25
|
作者
Pietersz, RNI
van der Meer, PF
Steneker, I
Hinloopen, B
Dekker, WJA
van Zanten, AP
Reesink, HW
机构
[1] Red Cross Blood Bank, NL-1006 AC Amsterdam, Netherlands
[2] Slotervaart Hosp, Amsterdam, Netherlands
关键词
D O I
10.1159/000031057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Our requirements for leukocyte-depleted platelet concentrates (LD-PC) for an adult patient are: platelets >240X10(9), leukocytes <5x10(6), volume of 150-400 ml; and at the end of storage a pH between 6.8 and 7.4 and presence of the swirling effect. Our aim was to develop a standardized, semiautomated method for the production of LD-PC, by pooling of buffy coats (BC), and prestorage leukoreduction by filtration. Materials and Methods: Whole blood was collected in Top and Bottom systems, and separated automatically with the Compomat(TM) G3 equipment into a red cell concentrate, a plasma and a BC. Subsequently, a pool of 5 BC was made, and 200 g plasma from one of the donors was added. Then, after soft spin centrifugation, the platelet rich plasma was leukocyte depleted by filtration using the Autostop(TM) BC filter, and stored in a 1,000 ml polyolefin platelet storage bag. Results: BC (n = 60) had a volume of 51+/-2 ml (mean +/- SD) with a hematocrit of 0.44+/-0.03 l/l and contained 80+/-5% of the platelets and 74+/-12% of the leukocytes of the whole blood. Rou tinely prepared LD-PC (n = 15,037) contained a median of 341x10(9) platelets (range 49-599x10(9)), with only 104/15,037 (0.7%) containing fewer than 240x10(9) platelets; the median volume was 263 ml (range 134-373 ml). In 118/917 (13%) LD-PC leukocytes were observed in the Nageotte hemocytometer, but only twice exceeding 1x10(6) leukocytes per unit, and none exceeding 5X10(6) (median <0.6x10(6); range <0.6-1.41x10(6)). Storage experiments of the LD-PC (n = 12) revealed adequate oxygenation and maintenance of pH and swirling effect up to 9 days. Conclusions: This method warrants with 99% confidence that LD-PC contain more than 240X10(9) platelets; with 97.5% confidence that 100% of the LD-PC contain <5X10(6) leukocytes, and with 95% confidence that more than 99% of the LD-PC contain fewer than 1x10(6) leukocytes; these LD-PC can be stored satisfactorily for up to 9 days.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 50 条
  • [1] Preparation of platelet concentrates from pooled buffy coats using the OrbiSac BC System
    Salado-Jimena, JA
    Hansen, MB
    TRANSFUSION, 2004, 44 (09) : 68A - 68A
  • [2] CYTOKINES IN PLATELET CONCENTRATES PREPARED FROM POOLED BUFFY COATS
    KLUTER, H
    MULLERSTEINHARDT, M
    DANZER, S
    WILHELM, D
    KIRCHNER, H
    VOX SANGUINIS, 1995, 69 (01) : 38 - 43
  • [3] Transfusion of platelet concentrates from pooled buffy-coats:: comparison of bedside vs. prestorage leukofiltration
    Müller-Steinhardt, M
    Schlenke, P
    Wagner, T
    Klüter, H
    TRANSFUSION MEDICINE, 2000, 10 (01) : 59 - 65
  • [4] CYTOKINE LEVEL DETERMINATION IN STORED BUFFY COATS (BC) AND POOLED PLATELET CONCENTRATES (PC)
    MASSE, M
    JEANROY, A
    BILLOT, M
    RACADOT, E
    COFFE, C
    TRANSFUSION, 1994, 34 (10) : S6 - S6
  • [5] QUALITY OF POOLED PLATELET CONCENTRATES PREPARED FROM BUFFY COATS AND STORED IN AN ADDITIVE SOLUTION AFTER FILTRATION
    KOERNER, K
    WEIHE, R
    SAHLMEN, P
    ZELLER, B
    SEIFRIED, E
    CARDOSO, M
    KUBANEK, B
    ANNALS OF HEMATOLOGY, 1995, 70 (02) : 97 - 102
  • [6] Automated preparation of platelet concentrates from pooled buffy coats using the Gambro OrbiSac system
    Gulliksson, H
    Sjödin, A
    Sandgren, P
    Vesterinen, M
    Larsson, S
    Diedrich, B
    TRANSFUSION AND APHERESIS SCIENCE, 2003, 29 (01) : 11 - 12
  • [7] IN-VITRO EVALUATION OF PLATELET CONCENTRATES, PREPARED FROM POOLED BUFFY COATS, STORED FOR AND DAYS AFTER FILTRATION
    BOOMGAARD, MN
    JOUSTRADIJKHUIS, AM
    GOUWEROK, CWN
    STENEKER, I
    REESINK, HW
    LOOS, JA
    PIETERSZ, RNI
    DEKORTE, D
    TRANSFUSION, 1994, 34 (04) : 311 - 316
  • [8] Automated preparation of platelet concentrates from pooled buffy coats:: in vitro studies and experiences with the OrbiSac system
    Larsson, S
    Sandgren, P
    Sjödin, A
    Vesterinen, M
    Gulliksson, H
    TRANSFUSION, 2005, 45 (05) : 743 - 751
  • [9] Evaluation of the in vitro Function of Platelet Concentrates from Pooled Buffy Coats or Apheresis
    Fiedler, Sarah Anna
    Boller, Klaus
    Junker, Ann-Christine
    Kamp, Christel
    Hilger, Anneliese
    Schwarz, Wolfgang
    Seitz, Rainer
    Salge-Bartels, Ursula
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2020, 47 (04) : 314 - 324
  • [10] Evaluation of storage conditions of platelet concentrates prepared from pooled buffy coats
    deWildtEggen, J
    Bins, M
    vanProoijen, HC
    VOX SANGUINIS, 1996, 70 (01) : 11 - 15