Optical coherence tomography (OCT) is a non-invasive high-resolution imaging technique that permits characterization of microarchitectural features in real time. Previous ex vivo studies have shown that the technique is capable of distinguishing between parathyroid tissue, thyroid tissue, lymph nodes, and adipose tissue. The purpose of this study was to evaluate the practicality of OCT during open and minimally invasive parathyroid and thyroid surgery. During parathyroid and thyroid surgery, OCT images were generated from parathyroid glands, thyroid tissue, lymph nodes, and adipose tissue. The images were immediately assessed by the operating team using the previously defined criteria. Second, the OCT images were blinded with respect to their origin and analyzed by two investigators. Whenever possible the OCT findings were matched to the corresponding histology. A total of 227 OCT images from 27 patients undergoing open or minimally invasive thyroid or parathyroid surgery were analyzed. Parathyroid glands were correctly identified in 69.2 %, thyroid tissue in 74.5 %, lymph nodes in 37.5 %, and adipose tissue in 69.2 %. 43 OCT images (18.9 %) could not be allocated to one of the tissue types (Table 2). Sensitivity and specificity in distinguishing parathyroid tissue from the other entities were 69 % (63 true positive, 13 false negative findings, 15 images where an allocation was not possible) and 66 %, respectively (71 true negative, 9 false positive, 28 images where an assessment was not possible). OCT is capable of distinguishing between parathyroid, thyroid, and adipose tissue. An accurate differentiation between parathyroid tissue and lymph nodes was not possible. The disappointing results compared to the previous ex vivo study are related to problems handling the endoscopic probe intraoperatively. However, further refinement of this new technology may lead to OCT systems with higher resolution and intraoperative probes that are easier to handle.
引用
收藏
页码:2698 / 2704
页数:7
相关论文
共 50 条
  • [1] Intraoperative optical coherence tomography imaging to identify parathyroid glands
    Sandra Sommerey
    Norah Al Arabi
    Roland Ladurner
    Constanza Chiapponi
    Herbert Stepp
    Klaus K. J. Hallfeldt
    Julia K. S. Gallwas
    Surgical Endoscopy, 2015, 29 : 2698 - 2704
  • [2] Optical Coherence Tomography as a Method to Identify Parathyroid Glands
    Ladurner, Roland
    Hallfeldt, Klaus K. J.
    Al Arabi, Norah
    Stepp, Herbert
    Mueller, Susanna
    Gallwas, Julia K. S.
    LASERS IN SURGERY AND MEDICINE, 2013, 45 (10) : 654 - 659
  • [3] Backscattering intensity measurements in optical coherence tomography as a method to identify parathyroid glands
    Sommerey, Sandra
    Ladurner, Roland
    Al Arabi, Norah
    Mortensen, Uwe
    Hallfeldt, Klaus
    Gallwas, Julia
    LASERS IN SURGERY AND MEDICINE, 2015, 47 (06) : 526 - 532
  • [4] The value of intraoperative optical coherence tomography imaging in vitreoretinal surgery
    Ehlers, Justis P.
    Tao, Yuankai K.
    Srivastava, Sunil K.
    CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (03) : 221 - 227
  • [5] Intraoperative Optical Coherence Tomography Imaging of the Peripheral Vitreous and Retina
    Nishitsuka, Koichi
    Nishi, Katsuhiro
    Namba, Hiroyuki
    Kaneko, Yutaka
    Yamashita, Hidetoshi
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2018, 38 (03): : E20 - E22
  • [6] Intraoperative Near-Infrared Autofluorescence and Indocyanine Green Imaging to Identify Parathyroid Glands: A Comparison
    Lerchenberger, Max
    Al Arabi, Norah
    Gallwas, Julia K. S.
    Stepp, Herbert
    Hallfeldt, Klaus K. J.
    Ladurner, Roland
    INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2019, 2019
  • [7] Optical Coherence Tomography Imaging of Human Lacrimal Glands: An In Vivo Study
    Doh, Sang Hee
    Kim, Eun Chul
    Chung, Se Yoon
    Kim, Man Soo
    Chung, Sung Kun
    Shin, Min Chul
    Hwang, Ho Sik
    OPHTHALMOLOGY, 2015, 122 (11) : 2364 - 2366
  • [8] Intraoperative Optical Coherence Tomography Enables Noncontact Imaging During Canaloplasty
    Siebelmann, Sebastian
    Cursiefen, Claus
    Lappas, Alexandra
    Dietlein, Thomas
    JOURNAL OF GLAUCOMA, 2016, 25 (02) : 236 - 238
  • [9] Optical Coherence Tomography: from Retina Imaging to Intraoperative Use - a Review
    Huettmann, G.
    Lankenau, E.
    Schulz-Wackerbarth, C.
    Mueller, M.
    Steven, P.
    Birngruber, R.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2009, 226 (12) : 958 - 964
  • [10] A novel optical approach to intraoperative detection of parathyroid glands
    McWade, Melanie A.
    Paras, Constantine
    White, Lisa M.
    Phay, John E.
    Mahadevan-Jansen, Anita
    Broome, James T.
    SURGERY, 2013, 154 (06) : 1371 - 1377