A capillary zone electrophoresis method for the assay and quality control of mesembrine in Sceletium tablets

被引:15
|
作者
Patnala, Srinivas [1 ]
Kanfer, Isadore [1 ]
机构
[1] Rhodes Univ, Div Pharmaceut, Fac Pharm, ZA-6140 Grahamstown, South Africa
基金
新加坡国家研究基金会;
关键词
Sceletium tablets; capillary zone electrophoresis; mesembrine; assay and quality control; fingerprinting;
D O I
10.1016/j.jpba.2008.01.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Sceletium plant has been reported to contain psychoactive alkaloids, specifically mesembrine, mesembrenone, mesembrenol and other related alkaloids. Sceletium is marketed through health shops and on the internet as dried plant powder and as pharmaceutical dosage forms. The objectives of this research was to develop and validate a capillary zone electrophoresis (CZE) method to identify five alkaloids and quantitatively determine the content of the important alkaloid, mesembrine in Sceletium tablets. Since reference standards of the relevant alkaloids are not commercially available for use in quality control of Sceletium products, it was necessary to isolate and characterize an appropriate analytical marker for use in the assay and additional markers for fingerprinting by CZE. The separation of the relevant alkaloids was carried out by CZE on a 50 cm effective length, fused silica capillary tubing (50 mu m i.d. x 360 mu m o.d.) using 50 mM of sodium dihydrogen orthophosphate dihydrate at pH 1.5 as the background electrolyte and monitored at a UV wavelength of 228 nm. All the marker alkaloids were found to be well resolved and were identified in the plant material and in commercially available Sceletium tablets based on the relative migration times (MTs) with respect to quinine hydrochloride that was used as an internal standard. The method was validated and used to assay the mesembrine content in Sceletium tablets. Calibration curves were found to be linear over the entire concentration range of 2.5-80 mu g/ml with correlation coefficients > 0.995. The accuracy was found to be 92.5 and 104.5% (R.S.D. < 3.5%) and the R.S.D.'s of the inter-day precision at low, medium and high tablet masses were better than 0.9, 2.2 and 2.7%, respectively. The recoveries were all within the range of 91.8 and 105.8% (R.S.D. < 8.5%) and the limit of quantitation (LOQ) and limit of detection (LOD) values were found to be 2.5 and 1.5 mu g/ml, respectively. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:440 / 446
页数:7
相关论文
共 50 条
  • [1] Forensic analysis of mesembrine alkaloids in Sceletium tortuosum by nonaqueous capillary electrophoresis mass spectrometry
    Roscher, Joerg
    Posch, Tjorben Nils
    Puetz, Michael
    Huhn, Carolin
    ELECTROPHORESIS, 2012, 33 (11) : 1567 - 1570
  • [2] Quality control of benserazide-levodopa and carbidopa-levodopa tablets by capillary zone electrophoresis
    Fanali, S
    Pucci, V
    Sabbioni, C
    Raggi, MA
    ELECTROPHORESIS, 2000, 21 (12) : 2432 - 2437
  • [3] Stability-indicating capillary zone electrophoresis assay for the analysis of linezolid in tablets
    Capistrano Goncalves de Oliveira, Cristiani Lopes
    Nunes Salgado, Herida Regina
    Leite Moraes, Maria de Lourdes
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 54 (04)
  • [4] Method Development and Validation for the Determination of Cabergoline in Tablets by Capillary Zone Electrophoresis
    Dogan, Aysegul
    Pehlivan, Ismail
    Basci, Nursabah E.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2011, 30 (01): : 132 - 138
  • [5] Development and validation of a capillary zone electrophoresis method for the determination of ofloxacin in tablets
    Elbashir, Abdalla A.
    Saad, Bahruddin
    Ali, Abdussalam Salhin Mohamed
    Saleh, Muhd Idiris
    Aboul-Enein, Hassan Y.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (18) : 2771 - 2783
  • [6] Lodenafil Carbonate Tablets: Optimization and Validation of a Capillary Zone Electrophoresis Method
    Codevilla, Cristiane F.
    Ferreira, Pamela Cristina L.
    Sangoi, Maximiliano S.
    Froeehlich, Pedro Eduardo
    Bergold, Ana Maria
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (11) : 2114 - 2121
  • [7] Capillary zone electrophoresis determination of loratadine in tablets
    Mikus, P
    Kubacák, P
    Valásková, I
    Havránek, E
    PHARMAZIE, 2004, 59 (04): : 260 - 262
  • [8] APPLICATIONS OF CAPILLARY ZONE ELECTROPHORESIS TO QUALITY-CONTROL
    NIELSEN, RG
    RICKARD, EC
    ACS SYMPOSIUM SERIES, 1990, 434 : 36 - 49
  • [9] Validated Method for the Determination of Piroxicam by Capillary Zone Electrophoresis and Its Application to Tablets
    Dal, Arin Gul
    Oktayer, Zeynep
    Dogrukol-Ak, Dilek
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2014, 2014
  • [10] A capillary zone electrophoresis (CZE) method for the determination of cyclizine hydrochloride in tablets and suppositories
    Mohammadi, A
    Kanfer, I
    Walker, RB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) : 233 - 239